Page 3 - WARNING
Front Matter WARNING Machine installations must comply with minimumspecifications and requirements stated in the appli-cable Installation Manual, any applicable municipalbuilding codes, water supply requirements, electricalwiring regulations and any other relevant statutoryregulations. Due to varied...
Page 4 - Table of Contents
Table of Contents Front Matter .......................................................................................... 3 Introduction ........................................................................................... 7 Model Identification ...................................................
Page 7 - Model Identification; Gas
Introduction Model Identification Information in this manual is applicable to these tumble dryermodels: Gas Steam/Thermal Oil Electric 25 Pound CHD25G2-CA025L CHD25G2-CA025N CHD25G2-CT025L CHD25G2-CT025N CHD25G2-CU025L CHD25G2-CU025N CK025N CK025R CT025R CU025R DR25G2-BA025L DR25G2-BA025N DR25G2-BK0...
Page 11 - Not Applicable
Gas Steam/Thermal Oil Electric 45 PoundStacked CKT45N CKT45R CTT45L CTT45N CTT45R DR445G2-BAT45L DR445G2-BAT45N DR445G2-BKT45N DR445G2-BKT45R DR445G2-BTT45D DR445G2-BTT45L DR445G2-BTT45N DR445G2-BTT45R DR445G2-BUT45L DR445G2-BUT45N DR445G2-BUT45R DRST45G2-BAT45L DRST45G2-BAT45N DRST45G2-BTT45D DRST4...
Page 16 - Nameplate Location
Gas Steam/Thermal Oil Electric 200 Pound CA200L CA200N CT200L CT200N CU200L CU200N DR200G2-BA200L DR200G2-BA200N DR200G2-BT200L DR200G2-BT200N DR200G2-BU200L DR200G2-BU200N HA200L HA200N HT200L HT200N HU200L HU200N IT200L IT200N SA200L SA200N ST200L ST200N SU200L SU200N UA200L UA200N UT200L UT200N U...
Page 17 - Figure 1; cation User Instructions; for additional information.; Default Global Settings; Rapid Advance = Disabled
Preliminary Information About the Control This control is an advanced, programmable computer that lets theowner control most machine features by pressing a sequence ofkeypads. The control allows the owner to program custom cycles, run di-agnostic cycles, and retrieve audit and error information. Tum...
Page 18 - PC and PDA Application User Instructions; Entering Program Mode
End of Cycle External Signal = Enabled (5 seconds) Clean Lint Screen Reminder = Off Display Limit Errors = Disabled Manual Diagnostics = Enabled *Manual Programming = Enabled **Reverse Cylinder Rotate Time = 30 (seconds) **Reverse Cylinder Stop Time = 6 (seconds) **Advanced Reversing = Disabled ***A...
Page 19 - Operational Keypad; Figure 2; Figure 2; H Models; Figure 3; U Models; Figure 4; Keypad
Control Identification Operational Keypad The control includes five keypads. These functions are availableto the operator and are intended to control and manage operationof the tumble dryer. Refer to Figure 2 , Figure 3 , Figure 4 , Fig- ure 5 and Table 1 . S Models TMB1345R_SVG Figure 2 H Models TM...
Page 20 - Table 1; Operation Modes
Keypad Description START Press to start the selected cycle, select an option when in the menu or save a valuewhen editing a parameter. Status Indicator LED Description PROGRAM LED will light up if the control is in Manual Programming Mode or if a cycle is beingmodified. REVERSING LED will light up w...
Page 21 - plication User Instructions
Time DryCycleDisplay 6 DigitDisplay Description Display 5 SAVE Custom Save Mode Dis-play Table 2 MoistureDry CycleDisplay 6 DigitDisplay Description Display 1 HH Actual Moisture Level Display 2 CHH SY orCHH Cd Cycle Number (HH) andSegment Number (Y) orCycle Number (HH) andSegment Cooldown Display 3 ...
Page 23 - Machine Cycle Operation; Time Dry Cycle; Rotation Sensor Equipped Machines; Press the Up or Down keypad to change cycles.
Machine Cycle Definition and Operation There are 30 machine cycles that can be selected and run. Ma-chine cycles can be modified or made “unavailable” by manuallyediting them in Modify Cycle Menu or by using the PDA todownload a modified machine cycle into the control. Machine cy-cles cannot be dele...
Page 24 - How to Enter the Manual Mode; Control must be in Idle Mode.
Entering the Manual Mode For programming, testing, and retrieving information from thecontrol, it is often necessary to enter the Manual Mode by follow-ing the steps below. For an overview of entering the Manual Mode, refer to the flow-chart. How to Enter the Manual Mode 1. Control must be in Idle M...
Page 25 - Manual Mode; Figure 6
Manual Mode : Enter by pressing Stop ( ), then Back ( ß ), then Up ( á ) keypads “ Prog ” Manual Programming “ Audit ” Manual Read Audit “ rESEt ” Manual Reset “ diAg ” Diagnostic Tests Press the Up ( á ) or the Down ( â ) keypad to scroll through the Manual Mode options. Press the Start ( / 8 ) key...
Page 26 - What Can Be Programmed?; Description
Programming Control What Can Be Programmed? This feature allows the owner to program cycle parameters andother features by using the keypads. The control must have theManual Programming Mode enabled, which is the factory de-fault. This mode can only be turned OFF and ON by using an ex-ternal device....
Page 30 - Figure 7
“ CyCLE- ” Cycle Programming “ CHHEn ” Cycle HH Enable Disable “ CyCHH ” Cycle to be programmed “ CHHtyP ” Cycle HH Type Press the “ CHHnt ” Cycle HH Material Type “ CHHtPt ” Cycle HH Time Past Target “ Prog ” Manual Programming “ On ” Enable “ oFF ” Disable “ tinE ” Time Dry “ Auto ” Auto Dry “ noi...
Page 31 - Figure 8
“ CHHS1- ” Segment 1 “ CHHS2- ” Segment 2 “ CHHS11 ” Segment 1 Enable/Disable “ CHHS12 ” Segment 1 Time “ CHHS13 ” Segment 1 Temperature “ CHHS14 ” Segment 1 Auto Dry Target Level “ CHHS15 ” Segment 1 Moisture Dry Target Level “ CHHS16 ” Segment 1 Reversing Enable/Disable “ CHHS21 ” Segment 2 Enable...
Page 32 - Figure 9
“ CHHS4- ” Segment 4 “ CHHS5- ” Segment 5 “ CHHS41 ” Segment 4 Enable/Disable “ CHHS42 ” Segment 4 Time “ CHHS43 ” Segment 4 Temperature “ CHHS44 ” Segment 4 Auto Dry Target Level “ CHHS45 ” Segment 4 Moisture Dry Target Level “ CHHS46 ” Segment 4 Reversing Enable/Disable “ CHHS51 ” Segment 5 Enable...
Page 37 - Table; How to Enter Audit Feature; ter the Manual Mode; How to Read Audit Data; Table 5; Table 5; once; How to Exit Audit Feature
Collecting Audit Information This feature allows the owner to retrieve audit information storedin the tumble dryer by pressing a sequence of pads on the control.For an explanation of the audit options available, refer to Table 5 . How to Enter Audit Feature 1. Control must be in Manual Mode to start...
Page 38 - Default Tumble Dryer Settings; Control must be in Manual Mode to start. Refer to
Manual Reset This feature allows the owner to reset the tumble dryer control’sprogramming data to the factory default settings by pressing a se-quence of pads on the control. For an explanation of the FactoryDefault Settings, refer to Default Tumble Dryer Settings . 1. Control must be in Manual Mode...
Page 39 - While a cycle is running, press the Back and Start keypads.
Custom Save This feature allows the owner to save a current cycle. For timedry cycles, the custom save will reprogram the cycle time to thetime that has elapsed in the current cycle. For moisture dry cy-cles, the custom save feature will save the current moisture levelas the target moisture level fo...
Page 40 - How to Enter Testing Feature; How to Enter the Manual; How to Start Tests; Table 6; How to Exit Testing Feature; Diagnostic (Testing) Mode – Quick Reference Chart
Testing Machine and Electronic Control Func- tions This feature allows the owner to run diagnostic tests on varioustumble dryer operations without servicing the tumble dryer. Thetests that are available are shown in Table 6 . For an overview of the manual diagnostic test feature, refer to theflowcha...
Page 43 - Diagnostic Test Descriptions
Diagnostic Test Descriptions Control Software Version Number Test This option displays the control software version number. Tostart test, control must be in the Testing Mode. Refer to How to Enter Testing Feature at the beginning of this section. To enter, press the Start keypad. The display will sh...
Page 44 - Table 7
DS8 DS7 DS6 DS5 DS4 DS3 DS2 DS1 Display OFF OFF OFF OFF ON OFF OFF OFF dSC008 OFF OFF OFF ON OFF OFF OFF OFF dSC016 OFF OFF ON OFF OFF OFF OFF OFF dSC032 OFF ON OFF OFF OFF OFF OFF OFF dSC064 ON OFF OFF OFF OFF OFF OFF OFF dSC128 Table 7 ICM Alarm Status This option shows the status of the ICM (Igni...
Page 46 - Production Test Cycle
NOTE: This test does not count towards the total ma-chine run time operation. To exit Damper Motor Test, press the Back keypad. The controlwill return to the testing mode. Reverse Motor Test This option shows the reverse motor running. To start test, control must be in the Testing Mode. Refer to How...
Page 48 - PDA Communications Error; Airflow Switch Sensed Closed While Not In Run Mode
Machine Errors PDA Communications Error These errors may occur during communications. When an erroroccurs, the display indicates the error message on the control fora few seconds. When a PDA communication error occurs, the au-dit counter Total Bad IR Communications is incremented, thehour, date, and...
Page 50 - play
Error Codes Following is a list of possible error codes for an electronic con-trol. Errors beginning with EI refer to external device Infra-redcommunication errors. All other errors refer to machine errors. Dis- play Description Cause/Corrective Action EI01 Transmission Failure Communication failure...
Page 52 - PC and PDA Application User Instruc-; Infra-red Communications
Communication Mode This mode is entered whenever the control is communicatingwith a PDA. Refer to PC and PDA Application User Instruc- tions . Infra-red Communications The Infra-red Communications feature allows the control to com-municate with an external device. The control can be program-med and ...