Page 3 - SERIAL NUMBER PREFIX: 3249A and above
Agilent 5071A Primary Frequency Standard Telecommunications Options Supplemental Manual This manual describes the Telecommunications options for the Agilent 5071A Primary Frequency Standard. The information in this manual applies toinstruments with one or more telecommunications options having the n...
Page 6 - Title Page, Serial Number Prefix; Throughout The Entire Manual
LIST OF EFFECTIVE PAGES SERIAL PREFIX, SERIAL #OR DATE CODE PAGES (05071-90042, December 2000) # All Serials ....................... 3-3. All Serials ....................... All pages. MANUAL CHANGES AGILENT 5071A TELECOMMUNICATIONS OPTIONS SUPPLEMENTAL MANUAL SERIAL PREFIX, SERIAL #OR DATE CODE CHA...
Page 7 - iii; Preface; How to Use This Manual v; Operating and Programming; Getting Started 1-3; Contents
iii Preface How to Use This Manual v Instrument Identification v Instruments Covered by This Manual vi Manual Organization vi How to Order Manuals vi 1 Operating and Programming Introduction 1-2 Introducing the HP 5071A 1-2 HP 5071A Major Features 1-2 Operating The HP 5071A 1-2 Clock Functions 1-2 G...
Page 8 - iv; Installation 1-10; Preparation for Use 1-10; Service; Performance Tests 2-2; Exchange Assemblies 2-19
Contents iv Installation 1-10 Preparation for Use 1-10 Power Requirements 1-10 Bench Operation 1-10 Operating the HP 5071A From External Dc Power 1-10 Preparing the HP 5071A For External Dc Operation 1-11Replacing the External Dc Input Power Fuse 1-11 Internal Standby Battery Maintenance 1-11 Long-T...
Page 9 - Specifications; Supplemental Characteristics 3-2; Power Requirements 3-2; Available Accessories and Options 3-4
Contents v 3 Specifications Supplemental Characteristics 3-2 Time Standard 3-2 Clock 1PPS Outputs 3-2Clock Synchronization 3-2 Internal Standby Battery (Nominal Values) 3-2Environmental 2-9 Power Requirements 3-2 Weight 3-3Accessories Furnished 3-3 dc input connector 3-3 Available Accessories and Op...
Page 11 - vii; How to Use This Manual; b. Text information explanation for
vii Preface This manual provides operating, programming, and assembly-level service information for the HP 5071A Primary Frequency Standard Telecommunications options. How to Use This Manual Telecommunications option information is presented as changes, additions, and deletions to the material cover...
Page 12 - viii; Instruments Covered by This manual
Preface viii Instruments Covered by This manual This manual applies to any HP 5071A Primary Frequency Standard that is equipped with one or more of the telecommunications options shown on the title page and has the same serial number prefix(es) also shown on the title page. If the serial number pref...
Page 14 - Introduction; Clock Functions; pps output: There is one 1 pps output on the 5071A front panel.
Operating and Programming Introduction 1-2 Introduction This section describes the additions, changes, and deletions to theinformation that appears in the introduction of the 5071A Operatingand Programming manual. Introducing the 5071A 5071A Major Features In the bulleted text delete: • 45 minute st...
Page 15 - Getting Started; Connectors; Rear-Panel Connections
Operating and Programming Getting Started 1-3 Getting Started This section describes the additions, changes, and deletions to theinformation that appears in chapter 1 of the 5071A Operating andProgramming manual. CHAPTER GUIDE Where to Find Important Topics In the bulleted list delete: • Powering Do...
Page 16 - 071A Rear Panel Connections; NOTE
Operating and Programming Getting Started 1-4 5071A Rear Panel Connections (See Table 1-1 in this chapter for connector descriptions) NOTE The illustration on these pages depicts an 5071A equipped withTelecomm Options 048 and 272. When the telecomm output optionincludes either 100 or 120 Ω balanced ...
Page 18 - Performing Basic Tasks; Synchronizing to an External 1 PPS Reference
Operating and Programming Getting Started 1-6 Table 1-1 Rear-Panel Telecommunications Options Connections Item Number Function Connector Type Signal Characteristics 1 8 kHz Sync In BNC (F) 8 kHz, TTL level, into 50 Ω 2 8 kHz Sync Out BNC (F) 8 kHz, TTL level, into 50 Ω 3* Framed Output BNC (F) 4.8 V...
Page 19 - Monitoring Status
Operating and Programming Using the 5071A 1-7 Using the 5071A This section describes the additions, changes, and deletions to theinformation that appears in chapter 2 of the 5071A Operating andProgramming manual. CHAPTER GUIDE All references to 1 PPS outputs and Sync inputs are singular. Chapter Sum...
Page 20 - In Case of Difficulty; Front-Panel Indicators and Messages; Operating System Failure
Operating and Programming In Case of Difficulty 1-8 In Case of Difficulty This section describes the additions, changes, and deletions to theinformation that appears in chapter 3 of the 5071A Operating andProgramming manual. Front-Panel Indicators and Messages Table 3-1. Front-Panel Status Lights Al...
Page 21 - SCPI Subsystem Commands; Status Reporting; Rear-Panel Status Output Operation; Status Output Programming
Operating and Programming 5071A Command References 1-9 5071A Command References This section describes the additions, changes, and deletions to theinformation that appears in chapter 5 of the 5071A Operating andProgramming manual. 5071A Command Summary SCPI Commands Table 5-2. SCPI Command Summary T...
Page 23 - Installation; Preparation for Use; Power Requirements; nd paragraph, 1st and 2nd sentences are changed:; Bench Operation; Operating the 5071A From External Dc Power
Operating and Programming Installation 1-11 Installation This section describes the additions, changes, and deletions to theinformation that appears in chapter 7 of the 5071A Operating andProgramming manual. CHAPTER GUIDE Chapter Summary In the bulleted list delete: • Internal Battery Maintenance 7-...
Page 24 - Preparing the RP 5071-A For External-Dc Operation; Internal Standby Battery Maintenance
Operating and Programming Installation 1-12 Preparing the RP 5071-A For External-Dc Operation Delete the existing procedure and use the following procedure 1. Connect the positive (+) terminal of the 40 to 58 Vdc power to the + screw terminal of INPUT 1 on the rear-panel 5-terminal barrier strip. 2....
Page 25 - Assembly-Level Service
Page 26 - Performance Tests; 071A Operational Verification; Rear-Panel Output Signal Checks; and has an additional sentence:
Assembly-Level Service Performance Tests 2-2 Performance Tests This section describes the additions, changes, and deletions to theinformation that appears in chapter 1 of the 5071A PrimaryFrequency Standard Assembly-Level Service manual. 5071A Operational Verification Rear-Panel Output Signal Checks...
Page 27 - Assembly Identification and Location; eight different telecommunications options:; TCO Option
Assembly-Level Service Service 2-3 Service This section describes the additions, changes, and deletions to theinformation that appears in chapter 2 of the 5071A PrimaryFrequency Standard Assembly-Level Service manual. Assembly Identification and Location Table 2-2. 5071A Assembly Identification The ...
Page 28 - Top-Level Diagnostic Tree Organization; Warning Message Diagnostic Tree (Diagnostic Subsection 4)
Assembly-Level Service Service 2-4 Figure 2-1. Instrument Top View The “Batteries (Hidden behind battery door)”callout is changed to: 48 Vdc Input Terminals and Fuse Top-Level Diagnostic Tree Organization Warning Message Diagnostic Tree (Diagnostic Subsection 4) On page 2-15, item number “1.4.4 Powe...
Page 29 - Warm-up and Fatal Error Diagnostic Tree
Assembly-Level Service Service 2-5 Warm-up and Fatal Error Diagnostic Tree (Diagnostic Subsection 3) 1.3.1.1 Operating Error-Code Interpretation On page 2-28, FIRST WORD message item 16 “SAW Osc unlocked” is changed to: 16. Unused bit, always 0 1.3.2.1 Cs Oven Failed: Ion Pump Overcurrent Warm-up Er...
Page 34 - Theory of Operation; A1 Motherboard Circuit Description; Simplified Functional Description; Figure 3-1. 5071 A Simplified Block Diagram
Assembly-Level Service Theory of Operation 2-10 Theory of Operation This section describes the additions, changes, and deletions to theinformation that appears in chapter 3 of the 5071A PrimaryFrequency Standard Assembly-Level Service manual. Introduction A1 Motherboard Circuit Description The secon...
Page 35 - Functional Block Descriptions; Figure 3-2. 5071 A Overall Block Diagram
Assembly-Level Service Theory of Operation 2-11 Input/Output Block The first sentence of the second paragraph is changed to: The block also receives a front-panel Sync-input signal to synchronizethe 1 pps output with an external system or event. Power Supply Block The text is changed to: The power s...
Page 36 - The A8 1 PPS Assembly has the following input/output changes:; Instrument Control Block; Operating Firmware: Warning Mode
Assembly-Level Service Theory of Operation 2-12 Figure 3-2. 5071 A Overall Block Diagram (Continued) The A8 1 PPS Assembly has the following input/output changes: Input B is deleted. Both rear-panel 1 PPS outputs are deleted. The Power-Supply Block has the following changes: The DC Power input volta...
Page 37 - Signal Name; The third paragraph on page 3-21 that describes A8 is changed:
Assembly-Level Service Theory of Operation 2-13 Table 3-2. Reference Oscillator/RF-Chain Block Interconnections The following interconnection information is added to table 3-2 on page 3-16: SourceModule orAssembly From PathConnectors Signal Name To PathConnectors DestinationModule orAssembly A9 N/A ...
Page 38 - Power Supply Block; The first sentence of the first paragraph at the top of page 3-22 is
Assembly-Level Service Theory of Operation 2-14 Power Supply Block The first sentence of the first paragraph at the top of page 3-22 is changed: The Power-Supply Block consists of LF1 line filter/cable assembly, T1toroidal power transformer, A1 rectifier/crowbar/Ext dc input filtercircuits, A11 powe...
Page 39 - Table 3-6. Power Supply Block Interconnections; The following signal name information in table 3-6 on page 3-23 is; Overvoltage Protection Circuit
Assembly-Level Service Theory of Operation 2-15 Table 3-6. Power Supply Block Interconnections The following signal name information in table 3-6 on page 3-23 is changed: • The voltage range in the third row is changed from 22-42 Volts to40-58 Volts. • The voltage range in the fourth row is changed ...
Page 40 - A11 Power Steering Logic Assembly; The circuit diagram on page 3-26 is changed:
Assembly-Level Service Theory of Operation 2-16 A11 Power Steering Logic Assembly The paragraph that describes the power-steering logic circuit on page 3- 25 is changed: A11 directs the outputs of two power sources to the main instrumentinput bus in a hierarchical order. The two power sources are: 1...
Page 41 - The slot/module interconnect diagram on page 3-28 is changed:; 8V Subpanel Assembly; Figure 2-1. DC Input 1 and 2 Power Steering Schematic (48V Subpanel
Assembly-Level Service Theory of Operation 2-17 The slot/module interconnect diagram on page 3-28 is changed: The J3 Low Current Steering Logic connector does not have +5 VDC,POWER FAIL, or BAT VALID signals present. 48V Subpanel Assembly The schematic diagram in figure 2-1 below illustrates the wir...
Page 42 - The Power Supply block diagram on page 3-30 is changed:; B1 Internal-Standby Battery
Assembly-Level Service Theory of Operation 2-18 Figure 3-5. A1 Power-Supply Block Diagram The Power Supply block diagram on page 3-30 is changed: • The Ext DC Input voltage is 40-58 VDC, • The F2 fuse rating is 2.5A, • The T1 toroidal power transformer part number is 9100-5134, • The P/O B1 battery ...
Page 43 - Replaceable Parts; Exchange Assemblies
Assembly-Level Service Replaceable Parts 2-19 Replaceable Parts This section describes the additions, changes, and deletions to theinformation that appears in chapter 5 of the 5071A PrimaryFrequency Standard Assembly-Level Service manual. Exchange Assemblies Table 5-1. A9 Telecommunications Options ...
Page 45 - BACKDATING
Assembly-Level Service 2-21 BACKDATING This section describes the additions, changes, and deletions to theinformation that appears in chapter 7 of the 5071A PrimaryFrequency Standard Assembly-Level Service manual.
Page 48 - Supplemental Characteristics; Time Standard; Clock 1 PPS Outputs; All references to 1 PPS Outputs are singular.; Clock Synchronization; The 2nd sentence is changed:; Internal Standby Battery (Nominal Values); Power option is present.; Environmental
Specifications Supplemental Characteristics 3-2 Supplemental Characteristics This section describes the additions, changes, and deletions to theinformation that appears in the Supplemental Characteristics sectionof the Specification chapter for either the HP 5071A Operating andProgramming manual or ...
Page 49 - The following are changed:; Accessories Furnished; The dc input connector description is changed:
Specifications Supplemental Characteristics 3-3 Weight The following are changed: Net weight: 28 kg (61 lb.). Shipping weight: 38 kg (83 lb.). Accessories Furnished dc input connector The dc input connector description is changed: 5-screw terminal standard barrier strip Option 048: Option 048:
Page 50 - Available Accessories and Options; Options
Specifications Available Accessories and Options 3-4 Available Accessories and Options This section describes the additions, changes, and deletions to theinformation that appears in the Available Accessories and Optionssection of the Specification chapter for either the HP 5071A Operatingand Program...
Page 51 - Service and Support
Printed in U.S.AData subject to changeRev 12/2000 Service and Support Contacting Agilent Technologies: For more information about Agilent test and measurement products, applications, and services, visit our web site at http://www.agilent.com/services/English/index.html. Agilent’s Test and Measuremen...
Page 53 - DECLARATION OF CONFORMITY
DECLARATION OF CONFORMITY According to ISO/IEC Guide 22 and CEN/CENELEC EN 45014 Manufacturer’s Name: Agilent Technologies, Inc. Manufacturer’s Address Santa Clara Site5301 Stevens Creek BoulevardSanta Clara, California 95052-8059 U.S.A. Declares, that the product Product Name: Primary Frequency Sta...