Agilent E3632A - Manual

Agilent E3632A

Agilent E3632A – Manual, read for free online in PDF format. We hope this helps you resolve any issues you may have. If you have further questions, please contact us through the contact form.

1 Page 1
2 Page 2
3 Page 3
4 Page 4
5 Page 5
6 Page 6
7 Page 7
8 Page 8
9 Page 9
10 Page 10
11 Page 11
12 Page 12
13 Page 13
14 Page 14
15 Page 15
16 Page 16
17 Page 17
18 Page 18
19 Page 19
20 Page 20
21 Page 21
22 Page 22
23 Page 23
24 Page 24
25 Page 25
26 Page 26
27 Page 27
28 Page 28
29 Page 29
30 Page 30
31 Page 31
32 Page 32
33 Page 33
34 Page 34
35 Page 35
36 Page 36
37 Page 37
38 Page 38
39 Page 39
40 Page 40
41 Page 41
42 Page 42
43 Page 43
44 Page 44
45 Page 45
46 Page 46
47 Page 47
48 Page 48
49 Page 49
50 Page 50
51 Page 51
52 Page 52
53 Page 53
54 Page 54
55 Page 55
56 Page 56
57 Page 57
58 Page 58
59 Page 59
60 Page 60
61 Page 61
62 Page 62
63 Page 63
64 Page 64
65 Page 65
66 Page 66
67 Page 67
68 Page 68
69 Page 69
70 Page 70
71 Page 71
72 Page 72
73 Page 73
74 Page 74
75 Page 75
76 Page 76
77 Page 77
78 Page 78
79 Page 79
80 Page 80
81 Page 81
82 Page 82
83 Page 83
84 Page 84
85 Page 85
86 Page 86
87 Page 87
88 Page 88
89 Page 89
90 Page 90
91 Page 91
92 Page 92
93 Page 93
94 Page 94
95 Page 95
96 Page 96
97 Page 97
98 Page 98
99 Page 99
100 Page 100
101 Page 101
102 Page 102
103 Page 103
104 Page 104
105 Page 105
106 Page 106
107 Page 107
108 Page 108
109 Page 109
110 Page 110
111 Page 111
112 Page 112
113 Page 113
114 Page 114
115 Page 115
116 Page 116
117 Page 117
118 Page 118
119 Page 119
120 Page 120
121 Page 121
122 Page 122
123 Page 123
124 Page 124
125 Page 125
126 Page 126
127 Page 127
128 Page 128
Page: / 128

Table of Contents:

  • Page 2 – DC Power Supply
  • Page 3 – The Front Panel at a Glance
  • Page 5 – Front-Panel Voltage and Current Limit Settings; blinking digit
  • Page 6 – Display Annunciators
  • Page 7 – The Rear Panel at a Glance
  • Page 8 – In This Book; Quick Start
  • Page 10 – Contents; Chapter 1 Specifications; To Program Overcurrent Protection 37; Chapter 3 Calibration Procedures; Measurement Techniques 47
  • Page 11 – Chapter 3 Calibration Procedures (continued); Constant Voltage (CV) Verifications 49; Chapter 4 Theory of Operation
  • Page 12 – Chapter 5 Service; Replaceable Parts 102; Chapter 7 Backdating
  • Page 14 – Specifications
  • Page 15 – The
  • Page 16 – Performance Specifications
  • Page 18 – Supplemental Characteristics
  • Page 23 – remote
  • Page 24 – To Prepare the Power Supply for Use; Check the list of supplied items.
  • Page 25 – Remove the power cord.
  • Page 26 – To Check the Rated Voltages of the Power Supply; For each step, use the keys shown on the left margins.; voltage; blinking
  • Page 27 – To Check the Rated Currents of the Power Supply; Turn on the power supply.
  • Page 29 – To Use the Power Supply in Constant Voltage Mode; For each step, use the keys shown on the left margin.; limit; current
  • Page 31 – To Use the Power Supply in Constant Current Mode; blinks
  • Page 33 – To Store and Recall the Instrument State; Set up the power supply for the desired operating state.
  • Page 35 – To Program Overvoltage Protection; Setting the OVP Level and Enable the OVP Circuit; Enter the OVP menu and set the trip level.
  • Page 36 – Checking OVP Operation; Clearing the Overvoltage Condition
  • Page 37 – annunciator will not
  • Page 38 – To Program Overcurrent Protection; Setting the OCP Level and Enable the OCP Circuit; Enter the OCP menu and set the trip level.
  • Page 39 – Checking OCP Operation; Clearing the Overcurrent Condition; blink
  • Page 40 – Chapter 2 Quick Start; To Rack Mount the Power Supply; To remove the rubber bumper, stretch a corner and then slide it off.
  • Page 42 – Calibration Procedures
  • Page 44 – Agilent Technologies Calibration Services
  • Page 45 – Automating Calibration Procedures; Agilent E3632A User's Guide; Recommended Test Equipment
  • Page 46 – Test Considerations; • Assure ambient relative humidity is less than 80%.
  • Page 47 – Performance Verification Tests; Performance Verification Tests
  • Page 48 – Measurement Techniques; Setup for Most Tests; Figure 3-1. Performance Verification Test Setup; Electronic Load
  • Page 49 – General Measurement Techniques; Front Panel Terminal Connections (Side View); Current-Monitoring Resistor
  • Page 50 – Constant Voltage Test Setup; OUTP ON; and; annunciators are on.
  • Page 51 – CV Load Regulation; annunciator remains lit. If not lit, adjust; annunciator; CV Line Regulation
  • Page 52 – annunciator remains lit. If not lit, adjust the load so; Normal Mode Voltage Noise (CV Ripple and Noise); Check that the front panel; annunciator remains lit. If not lit, adjust the load
  • Page 53 – Load Transient Response Time; ) of the transients at 15 mV from the base line is no
  • Page 54 – Constant Current Test Setup
  • Page 55 – CC Load Regulation; current monitoring
  • Page 56 – CC Line Regulation; Connect the ac power line through a variable voltage transformer.; Normal Mode Current Noise (CC Ripple and Noise); ) across output terminals to be tested. Connect a
  • Page 57 – Common Mode Current Noise; Turn off the power supply and connect a 100K
  • Page 58 – Performance Test Record for Agilent E3632A; CV Performance Test Record
  • Page 59 – Calibration Security Code
  • Page 60 – To Unsecure the Power Supply for Calibration; Turn on the front-panel calibration mode; secured
  • Page 61 – To Unsecure the Power Supply Without the Security Code; all
  • Page 62 – Calibration Count; calibration parameter; Calibration Message; does not
  • Page 63 – General Calibration/Adjustment Procedure; disconnect
  • Page 64 – Voltage and OVP Calibration; Move down a level to the voltage calibration mode; cal mode
  • Page 66 – Current and OCP Calibration
  • Page 67 – cal setup 3
  • Page 69 – Aborting a Calibration in Progress; cal setup 4
  • Page 70 – Calibration Record for Agilent E3632A
  • Page 71 – Error Messages; System Error Messages
  • Page 73 – Calibration Program
  • Page 78 – Theory of Operation
  • Page 79 – • Block Diagram Overview, page 79
  • Page 80 – Block Diagram Overview
  • Page 81 – Block Diagram
  • Page 82 – AC Input and Bias Supplies
  • Page 83 – Floating Logic
  • Page 87 – Power Mesh and Control; Refer to the schematics shown on page 121.
  • Page 89 – Earth-Referenced Logic; volt logic levels through on-chip; Front Panel
  • Page 90 – Service
  • Page 92 – Operating Checklist; Is the Power Supply Inoperative?; Verify that the ac power cord is connected to the power supply.
  • Page 93 – Types of Service Available; guarantee return of your failed power supply.
  • Page 94 – Repacking for Shipment; • Secure the container with strong tape or metal bands.
  • Page 95 – Electrostatic Discharge (ESD) Precautions; Surface Mount Repair; only; To Replace the Power-Line Fuse
  • Page 96 – To Disconnect the Output Using an External Relay; output is available on the RS-232 connector pin 1 and pin 9.; Installation Procedure; Reassemble the power supply.
  • Page 97 – Troubleshooting Hints; C a u t i o n; Unit is Inoperative
  • Page 98 – Bias Supplies Problems; Check the voltages of bias supplies as tabulated below.
  • Page 102 – Replaceable Parts
  • Page 103 – SDJH; To Order Replaceable Parts
  • Page 105 – Chapter 6 Replaceable Parts
  • Page 113 – E3632A Power SupplyAssembly
  • Page 114 – Manufacturer’s List
  • Page 116 – Backdating
  • Page 117 – LQFOXGHGLQWKLVFKDSWHU
  • Page 118 – Schematics
  • Page 119 – FKDSWHU7KHEORFNGLDJUDPDQGVFKHPDWLFVVXSSRUWWKHWKHRU\RI
Loading the manual

Service Guide

3DUW1XPEHU(

$SULO

)RU:DUUDQW\LQIRUPDWLRQUHIHUWRWKHEDFNRIWKHPDQXDO

‹&RS\ULJKW$JLOHQW7HFKQRORJLHV,QF
$OO5LJKWV5HVHUYHG

$JLOHQW($

'&3RZHU6XSSO\

"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.

Summary

Page 2 - DC Power Supply

The Agilent E3632A is a high performance 120 watt-dual range DC power supply with GPIB and RS-232 interfaces. The combination of bench-top and system features in this power supply provides versatile solutions for your design and test requirements. Convenient bench-top features • Dual range • Easy-to...

Page 3 - The Front Panel at a Glance

2 The Front Panel at a Glance 1 15V/7A range selection key2 30V/4A range selection key3 Overvoltage protection key4 Overcurrent protection key5 Display limit key6 Recall operating state key7 Store operating state/Local key 8 Error/Calibrate key 9 I/O Configuration/Secure key10 Output On/Off key11 Co...

Page 5 - Front-Panel Voltage and Current Limit Settings; blinking digit

4 Front-Panel Voltage and Current Limit Settings You can set the voltage and current limit values from the front panel using the following method. 1 Select the desired range using the range selection keys after turning on the power supply. 2 Press the key to show the limit values on the display. 3 M...

Other Agilent Models

All Agilent Other