EKI-7657C _Manual_ed1 ii Copyright The documentation and the software included with this product are copyrighted 2007 by Advantech Co., Ltd. All rights are reserved. Advantech Co., Ltd. reserves the right to make improvements in the products described in this manual at any time without notice. No pa...
v Safety Instructions 1. Read these safety instructions carefully. 2. Keep this User's Manual for later reference. 3. Disconnect this equipment from any AC outlet before cleaning. Use a damp cloth. Do not use liquid or spray detergents for cleaning. 4. For plug-in equipment, the power outlet socket ...
EKI-7657C _Manual_ed1 vi Safety Precaution - Static Electricity Follow these simple precautions to protect yourself from harm and the products from damage. 1. To avoid electrical shock, always disconnect the power from your PC chassis before you work on it. Don't touch any components on the CPU card...
vii Contents Contents Chapter 1 Overview ........................................... 2 1.1 Introduction ......................................................... 2 1.1.1 The SFP Advantage .................................. 2 1.1.2 High-Speed Transmissions ....................... 2 1.1.3 Dual Power I...
EKI-7657C _Manual_ed1 viii Figure 3.2: COM Port Properties Setting .................... 26 Figure 3.3: Login Screen: RS-232 Configuration ....... 26 Figure 3.4: Command Line Interface .......................... 27 3.1.1 Commands Level..................................... 27 Table 3.1: Command Level ...
ix Contents Figure 3.13: TFTP – Update Firmware ....................... 45 Figure 3.14: TFTP – Restore Configuration................ 46 Figure 3.15: TFTP – Backup Configuration................ 46 Figure 3.16: Syslog Configuration .............................. 47 Figure 3.17: SMTP Configuration .......
EKI-7657C _Manual_ed1 x Figure 3.55: All MAC Address interface .................... 89 Figure 3.56: Factory Default interface ........................ 90 Figure 3.57: Save Configuration interface .................. 91 Figure 3.58: System Reboot interface ......................... 92 Chapter 4 Troubl...
1 Chapter1 Overview Sections include: z Introduction z Features z Specifications z Packing List z Safety Precaution CHAPTER
EKI-7657C _Manual_ed1 2 Chapter 1 Overview 1.1 Introduction To create reliability in your network, the EKI-7657C comes equipped with a proprietary redundant network protocol—X-Ring that was developed by Advantech, which provides users with an easy way to establish a redundant Ethernet network with u...
3 Chapter1 1.1.5 Flexible Mounting EKI-7657C is compact and can be mounted on a DIN-rail or panel, so it is suitable for any space-constrained environment. 1.1.6 Advanced Protection The power line of EKI-7657C supports up to 3,000 V DC EFT protection, which secure equipment against unregulated volta...
EKI-7657C _Manual_ed1 4 1.2 Features • 3 Gigabit Copper/SFP combo ports, plus 7 Fast Ethernet ports • SFP socket for Easy and Flexible Fiber Expansion • Redundancy: Gigabit X-Ring (ultra high-speed recovery time<10ms), RSTP/STP (802.1w/1D) • Management: Web, Telnet, Serial Console, Windows Utilit...
5 Chapter1 1.3 Specification Communications Standard IEEE 802.3, 802.3ab, 802.3ad, 802.3u, 802.3x, 802.3z IEEE 802.1ab, 802.1D, 802.1w, 802.1p, 802.1Q, 802.1X LAN 10/100/1000Base-TX, Optional 100Base-FX, 1000Base-SX/LX/LHX/XD/ZX/EZX Transmission Distance Ethernet: Up to 100m (4-wire Cat.5e, Cat.6 RJ...
EKI-7657C _Manual_ed1 6 ESD (Ethernet) 4,000 V DC Surge (EFT for power) 3,000 V DC Reverse Polarity Present Environment Operating Temperature -10 ~ 60 o C (14 ~ 140 o F) Operating Humidity 5 ~ 95% (non-condensing) Storage Temperature -40 ~ 85 o C (-40 ~ 185 o F) Storage Humidity 0 ~ 95% (non-condens...
7 Chapter1 1.4 Packing List • 1 x EKI-7657C Industrial Managed Gigabit Ethernet Switch • 1 x eAutomation Industrial Communication CD-ROM with software, and User manual • 2 x Wall Mounting Bracket and Screws • 1 x DIN-rail Mounting Bracket and Screws • 1 x 8-pin RJ-45 to RS-232 serial cable • 1 x DC ...
9 Chapter2 Installation Sections include: z LED Indicators z Dimensions z Mounting z Network Connection z Connection to a Fiber Optic Network z Power Connection CHAPTER
EKI-7657C _Manual_ed1 10 Chapter 2 Installation In this chapter, you will be given an overview of the EKI-7657C hardware installation procedures. 2.1 LED Indicators There are few LEDs display the power status and network status located on the front panel of EKI-7657C, each of them has its own specif...
11 Chapter2 2.2 Dimensions (units: mm) Figure 2.1: Front View of EKI-7657C
15 Chapter2 2.3 Mounting The EKI-7657C supports two mounting methods: DIN-rail & Wall. 2.3.1 Wall mounting EKI-7657C can be wall-mounted by using the included mounting kit. Then, hang on the EKI-7657C to the nails on the wall. First, use the screws included in the package to combine the EKI-7657...
17 Chapter2 Then, let the device down straight to slide over the rail smoothly. See Figure 2.7. Figure 2.7: Installation to DIN-rail Step 2
EKI-7657C _Manual_ed1 18 2.4 Network Connection The EKI-7657C has 7 x RJ-45 ports that support connection to 10 Mbps Ethernet, or 100 Mbps Fast Ethernet, and half or full duplex operation. EKI-7657C can be connected to other hubs or switches via a twisted-pair straight-through or crossover cable up ...
EKI-7657C _Manual_ed1 20 To remove the LC connector from the transceiver, please follow the steps shown below: First, press the upper side of the LC connector to release from the transceiver and pull it out. Figure 2.11: Remove LC connector Second, push down the metal loop and pull the transceiver o...
21 Chapter2 2.6 Power Connection The EKI-7657C supports dual +12 ~ 48 V DC power inputs and power-fail relay output. Figure 2.13: Pin Assignment of the Power Connector You can connect an alarm indicator, buzzer or other signaling equipment through the relay output. The relay opens if power input 1, ...
EKI-7657C _Manual_ed1 22 2.7 Wiring the Digital Inputs/Outputs EKI-7657C is equipped with two sets of digital input/output contacts of the terminal block connector. Connect the wires to DI0, DI1, DO0, DO1, and GND respectively. GND is the common ground for DI0, DI1, DO0, and DO1. Don’t connect DO0/D...
EKI-7657C _Manual_ed1 24 Configuration Sections include: z RS-232 Console z Web Browser z Mounting z Self Diagnosis CHAPTER
25 Chapter3 Chapter 3 Configuration The EKI-7657C can be configured in two ways: via RS-232 Console or a web browser. 3.1 RS-232 Console EKI-7657C’s RS-232 console is designed for rapidly configuring which provides the console management—CLI command. Attach the supplied cable, which one end is RJ-45...
27 Chapter3 After you have logged in to the system, you will see a command prompt. To enter CLI management interface, type in the “ enable ” command. Figure 3.4: Command Line Interface The following table lists the CLI commands and description. 3.1.1 Commands Level Table 3.1: Command Level Modes Acc...
29 Chapter3 dhcpserver subnetmask [Subnet mask] G Configure subnet mask for DHCP clients switch(config)# dhcpserver subnetmask 255.255.255.0 dhcpserver gateway [Gateway] G Configure gateway for DHCP clients switch(config)# dhcpserver gateway 192.168.1.254 dhcpserver dnsip [DNS IP] G Configure DNS IP...
EKI-7657C _Manual_ed1 30 bandwidth type all I Set interface ingress limit frame type to “accept all frame” switch(config)# interface fastEthernet 2 switch(config-if)# bandwidth type all bandwidth type broadcast-multicast-flooded-unicast I Set interface ingress limit frame type to “accept broadcast, ...
31 Chapter3 aggregator group [GroupID] [Port-list] nolacp G Assign a static trunk group. [GroupID] :1~3 [Port-list]:Member port list, This parameter could be a port range(ex.1-4) or a port list separate by a comma(ex.2, 3, 6) switch(config)# aggregator group 1 2-4 nolacp or switch(config)# aggregato...
EKI-7657C _Manual_ed1 32 vlan 8021q trunk [PortNumber] access-link untag [UntaggedVID] V Assign a access link for VLAN by trunk group switch(vlan)# vlan 8021q trunk 3 access-link untag 33 vlan 8021q trunk [PortNumber] trunk-link tag [TaggedVID List] V Assign a trunk link for VLAN by trunk group swit...
33 Chapter3 position as the root switch. stp-admin-p2p [Auto|True|False] I Admin P2P of STP priority on this interface. switch(config)# interface fastEthernet 2 switch(config-if)# stp-admin-p2p Auto stp-admin-edge [True|False] I Admin Edge of STP priority on this interface. switch(config)# interface...
EKI-7657C _Manual_ed1 34 Table 3.10: Mac/Filter Table Commands Set Netstar Commands Level Description Example mac-address-table static hwaddr [MAC] I Configure MAC address table of interface (static). switch(config)# interface fastEthernet 2 switch(config-if)# mac-address-table static hwaddr 0000123...
35 Chapter3 sub-oid [OID] show snmp P Show SNMP configuration switch# show snmp no snmp community-strings [Community] G Remove the specified community. switch(config)# no snmp community-strings public no snmp-server host [Host-address] G Remove the SNMP server host. switch(config)# no snmp-server ho...
EKI-7657C _Manual_ed1 36 change the radius server port 8021x system accountport [port ID] G Use the 802.1x system account port global configuration command to change the accounting port switch(config)# 8021x system accountport 1813 8021x system sharedkey [ID] G Use the 802.1x system share key global...
37 Chapter3 systemlog mode [client|server|both] G Specified the log mode switch(config)# systemlog mode both show systemlog E Displays system log. Switch> show systemlog show systemlog P Show system log client & server information switch# show systemlog no systemlog G Disable systemlog functo...
39 Chapter3 3.2 Web Browser EKI-7657C provides a convenient configuring way via web browser. You can follow the steps below to access EKI-7657C. EKI-7657C’s default IP is 192.168.1.1. Make sure your host PC and EKI-7657C are on the same logical sub-network. Warning Your host PC should be in the same...
EKI-7657C _Manual_ed1 42 IP Configuration User can configure the IP Settings and DHCP client function here. • DHCP Client : Enable or disable the DHCP client function. When DHCP client function is enabled, the industrial switch will be assigned an IP address from the network DHCP server. The default...
43 Chapter3 DHCP Server—System configuration DHCP is the abbreviation of Dynamic Host Configuration Protocol that is a protocol for assigning dynamic IP addresses to devices on a network. With dynamic addressing, a device can have a different IP address every time it connects to the network. In some...
45 Chapter3 TFTP—Update Firmware Trivial File Transfer Protocol (TFTP) is a very simple file transfer protocol, with the functionality of a very basic form of FTP. It provides the functions to allow the user to update the switch firmware. Before updating, make sure you have your TFTP server ready an...
EKI-7657C _Manual_ed1 46 Figure 3.14: TFTP – Restore Configuration TFTP—Backup Configuration You can save current Flash ROM value from the switch to TFTP server for restoring later. • TFTP Server IP Address: Fill in the TFTP server IP • Backup File Name: Fill in the file name • Click Apply . Figure ...
47 Chapter3 System Event Log—Syslog Configuration Configure the system event mode to collect system log. • Syslog Client Mode: Select the system log mode— Client Only , Server Only , or Both . • System Log Server IP Address: Assign the system log server IP. • When Syslog Client Mode is set as Client...
EKI-7657C _Manual_ed1 48 • Sender: Type in an alias of the switch in complete email address format, e.g. [email protected] , to identify where the event log comes from. • Authentication: Tick the checkbox to enable this function, configuring the email account and password for authentication (when Ema...
49 Chapter3 • Port event selection: Also, before the drop-down menu items are available, the Syslog Client Mode column on the Syslog Configuration tab/E-mail Alert column on the SMTP Configuration tab must be enabled first. Those drop-down menu items have 3 selections—Link UP, Link Down, and Link UP...
51 Chapter3 SNTP Configuration You can configure the SNTP (Simple Network Time Protocol) settings which allow you to synchronize switch clocks on the Internet. • SNTP Client: Enable/disable SNTP function to get the time from the SNTP server. • Daylight Saving Time: Enable/disable daylight saving tim...
EKI-7657C _Manual_ed1 52 ZP5 - USSR Zone 4 +5 hours 5 pm ZP6 - USSR Zone 5 +6 hours 6 pm WAST - West Australian Standard +7 hours 7 pm CCT - China Coast, USSR Zone 7 +8 hours 8 pm JST - Japan Standard, USSR Zone 8 +9 hours 9 pm EAST - East Australian Standard GST Guam Standard, USSR Zone 9 +10 hours...
53 Chapter3 IP Security IP security function allows the user to assign 10 specific IP addresses that have permission to access the switch through the web browser for the securing switch management. • IP Security Mode: When this option is in Enable mode, the Enable HTTP Server and Enable Telnet Serve...
EKI-7657C _Manual_ed1 54 User Authentication Change web management login user name and password for the management security issue. • User name: Key in the new user name (The default is “admin”). • Password: Key in the new password (The default is “admin”). • Confirm password: Re-type the new passwor...
57 Chapter3 3.2.2 Port Port setting includes Port Statistics, Port Control, Port Trunk, Port Mirroring, and Rate Limiting. The user can use this interface to set the parameters and control the packet flow among the ports. Port Statistics The following information provides the current port statistic ...
59 Chapter3 Port Trunk The Link Aggregation Control Protocol (LACP) provides a standardized means for exchanging information between Partner Systems on a link to allow their Link Aggregation Control instances to reach agreement on the identity of the Link Aggregation Group to which the link belongs,...
EKI-7657C _Manual_ed1 60 Figure 3.26: 2 work ports with LACP enabled Aggregator Information When you have set up the aggregator setting with LACP disabled, you will see the local static trunk group information as below. Figure 3.27: 2 work ports with LACP disabled
61 Chapter3 Figure 3.28: Static trunking group of 2 ports on single switch When you have set up the aggregator setting of two interconnected switches with LACP enabled, you will see the respective LACP trunk group information as below. ‘Actor’ means the switch which is connecting to the host compute...
63 Chapter3 Port Mirroring The Port mirroring is a method for monitoring traffic in switched networks. Traffic through ports can be monitored by one specific port which means traffic goes in or out monitored (source) ports will be duplicated into mirroring (destination) port. • Destination Port: The...
EKI-7657C _Manual_ed1 64 Rate Limiting Here you can set up every port’s frame limitation type and bandwidth rate. • Ingress Limit Frame type: Select the frame type you want to filter. The frame types have 4 options for selecting: All, Broadcast/Multicast/Flooded Unicast, Broadcast/Multicast, and Bro...
65 Chapter3 3.2.3 Protocol The user can set the layer 2 protocol setting via this interface. VLAN configuration A Virtual LAN (VLAN) is a logical network grouping that limits the broadcast domain, which would allow you to isolate network traffic, so only the members of the same VLAN will receive tra...
EKI-7657C _Manual_ed1 66 Figure 3.34: Port based mode • Pull down the selection item and focus on Port Based then press Apply to set the VLAN Operation Mode in Port Based mode. • Click Add to add a new VLAN group.
67 Chapter3 Figure 3.35: Port based mode-Add interface • Enter the group name and VLAN ID. Add the port number having selected into the right field to group these members to be a VLAN group or remove any of them listed in the right field from the VLAN. • And then, click Apply to have the settings ta...
EKI-7657C _Manual_ed1 68 Figure 3.36: Port Based Edit/Delete interface • Use Delete to delete the VLAN. • Use Edit to modify group name, VLAN ID, or add/remove the members of the existing VLAN group. Note Remember to execute the “ Save Configuration ” action, otherwise the new configuration will los...
69 Chapter3 • Pull down the selection item and focus on 802.1Q then press Apply to set the VLAN Operation Mode in 802.1Q mode. • Enable GVRP Protocol: Tick the checkbox to enable GVRP protocol. This checkbox is available while the VLAN Operation Mode is in 802.1Q mode. • Management VLAN ID: The defa...
EKI-7657C _Manual_ed1 70 • Click Edit . Figure 3.38: Edit Group Configuration interface • You can Change the VLAN group name and VLAN ID. Figure 3.39: 802.1Q Group Configuration-Edit • Click Apply . Rapid Spanning Tree
71 Chapter3 The Rapid Spanning Tree Protocol (RSTP) is an evolution of the Spanning Tree Protocol and provides for faster spanning tree convergence after a topology change. The system also supports STP and the system will auto-detect the connected device that is running STP or RSTP protocol.
EKI-7657C _Manual_ed1 72 RSTP—System Configuration • The user can view spanning tree information of the Root Bridge. • The user can modify RSTP state. After modification, click Apply . ¾ RSTP mode: The user must enable the RSTP function first before configuring the related parameters. ¾ Priority (0-...
73 Chapter3 • Admin P2P: Some of the rapid state transactions that are possible within RSTP are dependent upon whether the port concerned can only be connected to exactly one other bridge (i.e. it is served by a point-to-point LAN segment), or can be connected to two or more bridges (i.e. it is serv...
EKI-7657C _Manual_ed1 74 SNMP Configuration Simple Network Management Protocol (SNMP) is the protocol developed to manage nodes (servers, workstations, routers, switches and hubs etc.) on an IP network. SNMP enables network administrators to manage network performance, find and solve network problem...
75 Chapter3 A trap manager is a management station that receives the trap messages generated by the switch. If no trap manager is defined, no traps will be issued. Create a trap manager by entering the IP address of the station and a community string. To define a management station as a trap manager...
EKI-7657C _Manual_ed1 76 Figure 3.44: SNMP V3 Configuration interface Group Table Configure SNMP v3 group table. • Security Name (User ID): Assign the user name that you have set up in user table. • Group Name: Set up the group name. • Click Add to add context name. • Click Remove to remove the unwa...
77 Chapter3 Access Table Configure SNMP v3 access table. • Context Prefix: Set up the context name. • Group Name: Set up the group. • Security Level: Set up the access level. • Context Match Rule: Select the context match rule. • Read View Name: Set up the read view. • Write View Name: Set up the wr...
EKI-7657C _Manual_ed1 78 QoS Configuration Here you can configure Qos policy and priority setting, per port priority setting, COS and TOS setting. QoS Policy and Priority Type • Qos Policy: Select the QoS policy rule. ¾ Use an 8,4,2,1 weighted fair queuing scheme : The switch will follow 8:4:2:1 rat...
79 Chapter3 Port Base Priority Configure the priority level for each port. With the drop-down selection item of Priority Type above being selected as Port-based, this control item will then be available to set the queuing policy for each port. • Port x: Each port has 4 priority levels—High, Middle, ...
EKI-7657C _Manual_ed1 80 IGMP Configuration The Internet Group Management Protocol (IGMP) is an internal protocol of the Internet Protocol (IP) suite. IP manages multicast traffic by using switches, routers, and hosts that support IGMP. Enabling IGMP allows the ports to detect IGMP queries, report p...
81 Chapter3 X-Ring X-Ring provides a faster redundant recovery than Spanning Tree topology. The action is similar to STP or RSTP, but the algorithms between them are not the same. In the X-Ring topology, every switch should be enabled with X-Ring function and two ports should be assigned as the memb...
83 Chapter3 LLDP Configuration LLDP (Link Layer Discovery Protocol) function allows the switch to advertise its information to other nodes on the network and store the information it discovers. • LLDP Protocol: Disable or enable LLDP function. • LLDP Interval: Set the interval of learning the inform...
87 Chapter3 MAC Address Table Use the MAC address table to ensure the port security. You can add a static MAC address; it remains in the switch's address table, regardless of whether the device is physically connected to the switch. This saves the switch from having to re-learn a device's MAC addres...
EKI-7657C _Manual_ed1 88 Figure 3.53: MAC Filtering interface • MAC Address : Enter the MAC address that you want to filter. • Click Add . • If you want to delete the MAC address from filtering table, select the MAC address and click Delete . MAC Address Table—All MAC Addresses You can view the port...
89 Chapter3 MAC Address Table—Multicast Filtering Multicasts are similar to broadcasts, they are sent to all end stations on a LAN or VLAN. Multicast filtering is the system by which end stations only receive multicast traffic if they register to join specific multicast groups. With multicast filter...
EKI-7657C _Manual_ed1 90 Factory Default Reset switch to default configuration. Click Reset to reset all configurations to the default value. Figure 3.56: Factory Default interface
91 Chapter3 Save Configuration Save all configurations that you have made in the system. To ensure the all configuration will be saved, click Save to save the all configuration to the flash memory. Figure 3.57: Save Configuration interface
EKI-7657C _Manual_ed1 92 System Reboot Reboot the switch in software reset. Click Reboot to reboot the system. Figure 3.58: System Reboot interface
EKI-7657C _Manual_ed1 94 Chapter 4 Troubleshooting Verify that you are using the right power cord/adapter (+12 ~ 48V DC ), please don’t use the power adaptor with DC output voltage higher than 48 V, or it will burn this converter down. Select the proper UTP cable to construct the user network. Use u...
EKI-7657C _Manual_ed1 96 Appendix A Pin Assignment & Wiring It is suggested to adopt ELA/TIA as the wiring of the RJ-45. Figure A.1: RJ-45 Pin Assignment Figure A.2: EIA/TIA-568B Figure A.3: EIA/TIA-568A
97 Figure A.4: DB 9-pin female connector DB9 Connector RJ-45 Connector NC 1 Orange/White 2 2 Orange 3 3 Green/White NC 4 Blue 5 5 Blue/White NC 6 Green NC 7 Brown/White NC 8 Brown
EKI-7657C _Manual_ed1 100 Appendix B Compatible SFP Modules The table below shows compatible SFP modules for EKI-7758F. Item Brand Part Number Mode Transmission Distance 1 AVAGO AFBR-5710PZ 550m 2 APAC LM28-C3S-TC-N 550m 3 HOATECH HTI8512-X5ATO 550m 4 SPACE SHUTTLE S56L-S85-6L-N Multi-mode 550m SP-G...
Advantech Manuals
-
Advantech PCM-3350 Series
Manual
-
Advantech PCL-849
Manual
-
Advantech EKI-2525P
Manual
-
Advantech PCA-6275
Manual
-
Advantech USB-4761
Manual
-
Advantech HMI-640S
Manual
- Advantech PCM-3362 Manual
- Advantech PCM-9372 Manual
-
Advantech 4718
Manual
- Advantech ARK-7480 Manual
-
Advantech SOM-4450 ETX
Manual
-
Advantech PCA-6774
Manual
-
Advantech SPC-57
Manual
-
Advantech UNO-1170
Manual
-
Advantech PPC-155T
Manual
-
Advantech TPC-1260
Manual
- Advantech PCM-9587 Manual
-
Advantech Touch Panel Computers
Manual
-
Advantech RMD-1150
Manual
-
Advantech PPC-120
Manual