Page 2 - 01 Explorer Boulevard
2 © 2004 ADTRAN, Inc. 61204025L1-1B Trademarks Any brand names and product names included in this manual are trademarks, registered trademarks, or trade names of their respective holders. To the Holder of the Manual The contents of this manual are current as of the date of publication. ADTRAN reserv...
Page 3 - Safety Instructions; risk of shock from lightning.; Save These Important Safety Instructions; Notes provide additional useful information.
61204025L1-1B © 2004 ADTRAN, Inc. 3 Safety Instructions When using your telephone equipment, please follow these basic safety precautions to reduce the risk of fire, electrical shock, or personal injury: 1. Do not use this product near water, such as a bathtub, wash bowl, kitchen sink, laundry tub, ...
Page 4 - Affidavit Requirements for Connection to Digital Services
4 © 2004 ADTRAN, Inc. 61204025L1-1B Affidavit Requirements for Connection to Digital Services • An affidavit is required to be given to the telephone company whenever digital terminal equipment without encoded analog content and billing protection is used to transmit digital signals containing encod...
Page 10 - Customer Service, Product Support Information, and Training
10 © 2004 ADTRAN, Inc. 61204025L1-1B Customer Service, Product Support Information, and Training ADTRAN will repair and return this product if within 5 years from the date of shipment the product does not meet its published specification or the product fails while in service. A return material autho...
Page 11 - have your unit serial number available when you call.
61204025L1-1B © 2004 ADTRAN, Inc. 11 have your unit serial number available when you call. Installation and Maintenance Support The ADTRAN Custom Extended Services (ACES) program offers multiple types and levels of installation and maintenance services which allow you to choose the kind of assistanc...
Page 13 - Table of Contents; Chapter 1
61204025L1-1C © 2004 ADTRAN, Inc. 13 Table of Contents Chapter 1 Introduction ...........................................................................................................19 T1/FT1 Overview ...................................................................................................
Page 15 - List of Figures
61204025L1-1B © 2004 ADTRAN, Inc. 15 List of Figures Figure 1-1. T1 ESF CSU ACE Application .............................................................................. 20Figure 1-2. T1 ESF CSU ACE Front View ............................................................................... 20Figure ...
Page 17 - List of Tables
61204025L1-1B © 2004 ADTRAN, Inc. 17 List of Tables Table A-1. RJ-48C Connector Pin Assignments......................................................................... 51Table A-2. EIA-232 Connector Pin Assignments ....................................................................... 51
Page 19 - Introduction; T1 SERVICE OFFERINGS
61204025L1-1B © 2004 ADTRAN, Inc 19 Chapter 1 Introduction T1/FT1 OVERVIEW T1 digital communication links have been used by telcos for the transmission of voice since the early sixties. The D4 channel bank is an example of a T1 digital carrier system that was introduced in the mid-seventies and is s...
Page 21 - Features; Smallest T1 ESF CSU ACE in the industry.
T1 ESF CSU ACE User Manual Chapter 1. Introduction 61204025L1-1B © 2004 ADTRAN, Inc 21 Figure 1-3. T1 ESF CSU Rear View Figure 1-4. Jack Signal Directions Features The following features give the T1 ESF CSU ACE many advantages over other products of its kind: • Smallest T1 ESF CSU ACE in the industr...
Page 22 - Interface Features
Chapter 1. Introduction T1 ESF CSU ACE User Manual 22 © 2004 ADTRAN, Inc 61204025L1-1B Interface Features NI (Labeled NET) The network interface (NI) port complies with the applicable ANSI and AT&T standards. Its features include the following: • D4 or ESF framing • AMI or B8ZS coding • Configur...
Page 23 - FOUR METHODS OF CONTROL; The T-Watch program has the following capabilities:; SNMP; or
T1 ESF CSU ACE User Manual Chapter 1. Introduction 61204025L1-1B © 2004 ADTRAN, Inc 23 FOUR METHODS OF CONTROL Front Panel The front panel provides complete and easy control of all items that can be configured through menu-guided options. The front panel LCD displays the status of operation and perf...
Page 24 - T1 ESF CSU ACE TESTING; The T1 ESF CSU ACE offers three forms of testing:; Self Test
Chapter 1. Introduction T1 ESF CSU ACE User Manual 24 © 2004 ADTRAN, Inc 61204025L1-1B T1 ESF CSU ACE TESTING The T1 ESF CSU ACE offers three forms of testing: • Self test • Loopback tests • Pattern generation Self Test The self test checks the integrity of the electronic components’ internal operat...
Page 25 - Loopback Tests; Network Loopbacks
T1 ESF CSU ACE User Manual Chapter 1. Introduction 61204025L1-1B © 2004 ADTRAN, Inc 25 Loopback Tests A number of different loopbacks can be invoked locally from the front panel, by T-Watch commands, or remotely by using special inband codes (AT&T network loop-up and loop-down codes). Additional...
Page 26 - Pattern Generation; All Ones; APPLICATIONS
Chapter 1. Introduction T1 ESF CSU ACE User Manual 26 © 2004 ADTRAN, Inc 61204025L1-1B Pattern Generation The T1 ESF CSU ACE offers three test patterns: All Ones, All Zeros, and 1:8. These patterns can be initiated from the front panel, through the EIA-232 control port, or remotely via a management ...
Page 29 - Chapter 2; Installation; UNPACK AND INSPECT; PWR
61204025L1-1B © 2004 ADTRAN, Inc 29 Chapter 2 Installation UNPACK AND INSPECT Carefully inspect the T1 ESF CSU ACE for any shipping damages. If damage is suspected, file a claim immediately with the carrier and then contact ADTRAN Technical Support. If possible, keep the original shipping container ...
Page 30 - WIRING; The connectors are described in this section.; OR
Chapter 2. Installation T1 ESF CSU ACE User Manual 30 © 2004 ADTRAN, Inc 61204025L1-1B WIRING The connectors are described in this section. RJ-48C Connectors Two RJ-48C connectors are located on the back end of the T1 ESF CSU ACE. The NET connector connects the unit to the network. The connector mar...
Page 31 - POWER-UP TESTING AND INITIALIZATION
T1 ESF CSU ACE User Manual Chapter 2. Installation 61204025L1-1B © 2004 ADTRAN, Inc 31 POWER-UP TESTING AND INITIALIZATION When shipped from the factory, the T1 ESF CSU ACE is set to factory default conditions. When power is applied, the unit automatically executes self test, followed by an initiali...
Page 33 - Chapter 3; Operation; FRONT PANEL OPERATION
61204025L1-1B © 2004 ADTRAN, Inc 33 Chapter 3 Operation The T1 ESF CSU ACE can be configured and controlled via the local front panel, the EIA-232 control port, or T-Watch. This chapter describes configuration from the front panel. FRONT PANEL OPERATION The T1 ESF CSU ACE front panel operating funct...
Page 34 - GENERAL FRONT PANEL MENU OPERATION; Data Field; Example Menu Operation; Selecting a Main Menu Item
Chapter 3. Operation T1 ESF CSU ACE User Manual 34 © 2004 ADTRAN, Inc 61204025L1-1B GENERAL FRONT PANEL MENU OPERATION The T1 ESF CSU ACE uses a multilevel menu structure containing both menu items and data fields. All menu operations and data are displayed in the LCD window. The menu items are numb...
Page 35 - Selecting a Submenu Item; Setting/Cancelling the Data Field; ENTER; Cancelling is available any time during the operation. If
T1 ESF CSU ACE User Manual Chapter 3. Operation 61204025L1-1B © 2004 ADTRAN, Inc 35 Selecting a Submenu Item To select the desired submenu item (similar to selecting a Main menu item), follow these steps: 1. Use the up and down scroll keys to place the cursor on the desired menu item, in this exampl...
Page 36 - View Display Only Data Fields; Press the; CANCEL; key to exit a menu field or return to a previous menu level.; MENU STRUCTURE
Chapter 3. Operation T1 ESF CSU ACE User Manual 36 © 2004 ADTRAN, Inc 61204025L1-1B View Display Only Data Fields Select the following menu choice to view an example of a display-only data field: 1. Select 1)STATUS from the Main menu. 2. Select submenu 2)NI ERR/ALM. 3. LOSS OF SIGNAL INACTIVE/ACTIVE...
Page 38 - DETAILED MENU OPERATION; button returns the
Chapter 3. Operation T1 ESF CSU ACE User Manual 38 © 2004 ADTRAN, Inc 61204025L1-1B Figure 3-8. Four Opening Menus and First Level Submenus Menu flow is normally depicted from left to right. Arrows on the lower right of the screen indicate the direction of scrolling to view additional menu items. At...
Page 40 - SES
Chapter 3. Operation T1 ESF CSU ACE User Manual 40 © 2004 ADTRAN, Inc 61204025L1-1B 1)NI PERF RPTS, Submenu of 1)STATUS The Network Interface Performance Reports menu item displays the user copy of the performance data. The T1 ESF CSU ACE maintains this performance data on the network in compliance ...
Page 41 - Frame Bit Errors; Frame bits received incorrectly at NI
T1 ESF CSU ACE User Manual Chapter 3. Operation 61204025L1-1B © 2004 ADTRAN, Inc 41 2)NI ERR/ALM, Submenu of 1)STATUS The NI ERR/ALM menu is used for viewing currently active/inactive errors and alarms on the network interface. Figure 3-12. First Current NI Errors/Alarms Screen The up and down scrol...
Page 43 - The fields and parameters available are as follows:
T1 ESF CSU ACE User Manual Chapter 3. Operation 61204025L1-1B © 2004 ADTRAN, Inc 43 Continue with standard operating procedures to edit the Network Interface parameters. The fields and parameters available are as follows: 1)FORMAT Sets the frame format for the NI. The factory default is ESF. D4 ESF ...
Page 45 - MODEM INIT; DISABLED
T1 ESF CSU ACE User Manual Chapter 3. Operation 61204025L1-1B © 2004 ADTRAN, Inc 45 2)UNIT, Submenu of 2)CONFIG This menu is used to change control port and alarm trap options. See Figure 3-16. Figure 3-16. First 2)UNIT Submenu SCreen 1)CONTROL PORT 8VHGWRVHWXSWKHXQLWWRLQLWLDOL]HDPRGHPDQGWKHFRQWUROS...
Page 46 - When editing a specific character, the scroll; ENTER a; Sets the frame format for the T1. The factory default is; ESF; Sets the line code for the T1. The factory default is
Chapter 3. Operation T1 ESF CSU ACE User Manual 46 © 2004 ADTRAN, Inc 61204025L1-1B 3)TEL NUM - This is the telephone number dialed for alarm traps transmission. The string can be up to 20 characters in length and is terminated with a semicolon (;). A colon (:) is used to represent a pause in the di...
Page 50 - Terminates pattern generation.; Press
Chapter 3. Operation T1 ESF CSU ACE User Manual 50 © 2004 ADTRAN, Inc 61204025L1-1B 3)TEST PATTERN, Submenu of 4)TEST Sets the pattern for the test and initiates the transmission of the pattern. The test is terminated by selecting NO PATTERN . There are four patterns available: NO PATTERN Terminates...
Page 51 - Appendix A; Pinouts
61204025L1-1B © 2004 ADTRAN, Inc 51 Appendix A Pinouts Table A-1. RJ-48C Connector Pin Assignments Table A-2. EIA-232 Connector Pin Assignments Pin Description NET CPE 1 R1 Receive data (from network to CSU) Transmit data (from CSU to DTE) 2 T1 Receive data (from network to CSU) Transmit data (from ...
Page 53 - Appendix B; Specification Summary; SPECIFICATIONS AND FEATURES
61204025L1-1B © 2004 ADTRAN, Inc 53 Appendix B Specification Summary SPECIFICATIONS AND FEATURES Specifications and features of the T1 ESF CSU ACE are provided in this chapter. Network Interface DSI interface per AT&T 62411 and ANSI T1.403 Network Framing Format D4 (SF) or ESF Network Line Code ...
Page 54 - Operating; CLEI: NCT1CD9BAA
Appendix B. Specification Summary T1 ESF CSU ACE User Manual 54 © 2004 ADTRAN, Inc 61204025L1-1B Environment Temperature: Operating 0 to 50 deg C (32 to 122 deg F) Storage -20 to 70 deg C (-4 to 158 deg F) Relative humidity: Up to 95%, noncondensing Hardware Specifications • Dimensions: 1.75”H x 6.2...
Page 55 - Appendix C; Acronyms/Abbreviations
61204025L1-1C © 2004 ADTRAN, Inc 55 Appendix C Acronyms/Abbreviations ACK acknowledgment ANSI American National Standards Institute AR access rate ARP address resolution protocol async asynchronous BECN backward explicit congestion notification BOP bit oriented protocol CCITT Consultive Committee fo...
Page 59 - Appendix D; Glossary
61204025L1-1B © 2004 ADTRAN, Inc 59 Appendix D Glossary 4-wire Switched 56 An AT&T proprietary 56/64 kbps switched digital data service offered by telco service providers and delivered to users over 4 copper wires. Compatible with the T1 ESF CSU ACE 4-wire Switched 56 DBU option. ANSI American N...
Page 65 - Index; Numerics
61204025L1-1B © 2004 ADTRAN, Inc. 65 Index Numerics 1 in 8 pattern 26 A ACCESS TYPE (REMOTE UNIT) 48 ADDRESS 47 ADTRAN PC program 23 ALARMS 45 all ones pattern 26 all zeroes pattern 26 applications 26 arrows, menus 34 ASCII terminal 23 B BIT STUFFING 44 C channel bank application 28 CODE 43 , 46 CON...