ADTRAN DE-4E - Manual
ADTRAN DE-4E – Manual, read for free online in PDF format. We hope this helps you resolve any issues you may have. If you have further questions, please contact us through the contact form.
Table of Contents:
- Page 2 – Part Number; Warranty and Customer; Time Slot Allocation; is equal to 4; Protected Loopback; for the latching; Table 2; and; Table 3; Byte Code; Table 1. Protected Loopback Mode Requirement
- Page 3 – Table 2. SW1 Option Settings
- Page 4 – Table 3. SW2 and SW3 Option Settings
- Page 5 – FT1 DP Option Selections; Configuration strap P1, illustrated in; Figure 2; Table 4. Front Panel Indicators and Switches; Description; On; Indicators; Figure 2. P1 Switch Location
- Page 6 – Figure 3. FT1 DP Edge Connector Wiring; Figure 3; for; DSL SYSTEM TESTING; shows the; FT1 DP Bantam Jacks; Figure 4. Bantam Jack Arrangement
- Page 7 – A terminal session is initiated by entering multiple; Definition
- Page 8 – The following screens can be accessed from the Main; Figure 7. FT1 DP Main Menu Screen
- Page 9 – The Current System Status Screen, illustrated in; Figure 8; , provides quick access to FT1 DP status; N O T E
- Page 10 – Figure 9; depicts the Performance History Screen.; Figure 9. Performance History Screen; depicts the FT1 DP Loopback Options
- Page 11 – shows the Provisioning Options screen.
- Page 13 – DSL DEPLOYMENT GUIDELINES; length including bridged tap lengths is 9 kft.; resistive termination, is; Table 6; Figure 14. DSL Deployment Guidelines
- Page 14 – Use; Table 7; to troubleshoot the FT1 DP.; Table 8; Carrier Networks Equipment Warranty,; Condition; off; Table 7. Troubleshooting Guide
- Page 15 – Table 8. FT1 DP Product Specifications; Fully compatible with Nortel DE-4E shelf
- Page 17 – GENERAL; shows the application from the central
- Page 19 – LOOPBACK ACTIVATION/DEACTIVATION; is a list of FT1 devices and their; LOOPUP STATE
1
Section 61245207L2-5, Issue 2
61245207L2-5C
CONTENTS
1.
GENERAL .................................................................. 1
2.
INSTALLATION ....................................................... 2
3.
CONNECTIONS ........................................................ 6
4.
DSL SYSTEM TESTING .......................................... 6
5.
CONTROL PORT OPERATION .............................. 7
6.
DSL DEPLOYMENT GUIDELINES ...................... 13
7.
MAINTENANCE ..................................................... 14
8.
TROUBLESHOOTING PROCEDURES ................ 14
9.
PRODUCT SPECIFICATIONS ............................... 14
10.
WARRANTY AND CUSTOMER SERVICE ......... 14
Appendix A. FT1 Loopbacks ........................................ A-1
FIGURES
Figure 1.
ADTRAN FT1 DP for Nortel DE-4E Shelf ... 1
Figure 2.
P1 Switch Location ......................................... 5
Figure 3.
FT1 DP Edge Connector Wiring .................... 6
Figure 4.
Bantam Jack Arrangement .............................. 6
Figure 5.
RS-232 (DB-9) Pin Assignments .................... 7
Figure 6.
Introductory Menu Screen .............................. 8
Figure 7.
FT1 DP Main Menu Screen ............................ 8
Figure 8.
Current System Status Screen ......................... 9
Figure 9.
Performance History Screen ......................... 10
Figure 10. Loopback Options Screen ............................. 10
Figure 11. Self-Test Options Screen .............................. 11
Figure 12. Provisioning Options Screen ........................ 11
Figure 13. Troubleshooting Screen ................................ 12
Figure 14. DSL Deployment Guidelines ........................ 13
Figure A-1. FT1 Loopbacks .......................................... A-1
Figure A-2. FT1 DP Network Loopback ....................... A-1
Figure A-3. FT1 DP CPE Loopback ............................. A-1
Figure A-4. FT1 Repeater #1 or # 2 Network Loopback . A-2
Figure A-5. FNID Network Loopback .......................... A-2
Figure A-6. FNID CPE Loopback ................................. A-2
TABLES
Table 1.
Protected Loopback Mode Requirement ........ 2
Table 2.
SW1 Option Settings ....................................... 3
Table 3.
SW2 and SW3 Option Settings ....................... 4
Table 4.
Front Panel Indicators and Switches .............. 5
Table 5.
Definition of Screen Abbreviations ................ 7
Table 6.
Loop Insertion Loss Data .............................. 13
Table 7.
Troubleshooting Guide ................................. 14
Table 8.
FT1 DP Product Specifications .................... 15
Table A-1. FT1 Loopback Select Codes ...................... A-1
Section 61245207L2-5C
Issue 3, July 2000
CLEI Code # D4D31R8D _ _
FT1 DP
Fractional T1 Dataport For Nortel DE-4E Shelf
Installation and Maintenance
1. GENERAL
This practice serves as an Installation and
Maintenance guide for the ADTRAN Fractional T1
Dataport (FT1 DP). The ADTRAN FT1 DP
(P/N 1245207L2) is the Central Office (CO) unit used
to deploy a repeater-less FT1 circuit using 2-wire
metallic facilities. The unit occupies one slot in a
standard Nortel DE-4E (or equivalent) shelf.
Figure 1
is an illustration of the ADTRAN FT1 DP.
Revision History
This is the third release of this document.
Clarifications were made to the SW1 Option Settings.
Description
Signals are provided to and from the channel bank or
RT, while 2B1Q HDSL signals are provided to the
local loop.
Trademarks: Any brand names and product names included in this document are
trademarks, registered trademarks, or trade names of their respective holders.
Figure 1. ADTRAN FT1 DP for Nortel DE-4E Shelf
1245207L1
FT1 DP
SX
2
3
4
5
6 7
8 9
10
11
12
O
U
T
I
N
R
X
DSO
T
X
ALM
AP
DSL
DS1
LB
R
S
2
3
2
L
O
C
R
E
M
"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.
Summary
2 Section 61245207L2-5, Issue 3 61245207L2-5C C A U T I O N C A U T I O N ! SUBJECT TO ELECTROSTATIC DAMAGE OR DECREASE IN RELIABILITY. HANDLING PRECAUTIONS REQUIRED. The FT1 Digital Subscriber Loop (DSL) local loopoperates as an independent subsystem, over a singletwisted pair. The FT1 DP communica...
3 Section 61245207L2-5, Issue 2 61245207L2-5C Switch Function Description SW1-1 ...... Code Select ............................................ SW1-1 On selects B8ZS line code. SW1-1 Off selects AMI. Off .......... AMI On .......... B8ZS SW1-2 ...... Framing ............................................
4 Section 61245207L2-5, Issue 3 61245207L2-5C Table 3. SW2 and SW3 Option Settings (Default settings are indicated in bold typeface) Switch Function Description SW3-4 ........... A/B Signaling for Channel 1 ....... Enables or Disables A/B Robbed Bit Signaling for Channel 1. Off ........ A/B Signalin...