Page 2 - C A U T I O N !; Electrical cable compliance; shows the Compliance Codes for HFAC. The; N O T E; Shelf Address Select Switches; Figure 2. Configuration and Shelf Address Switches; Code; IC
2 61221051L1-5, Issue 1 61221051L1-5A C A U T I O N ! SUBJECT TO ELECTROSTATIC DAMAGE OR DECREASE IN RELIABILITY. HANDLING PRECAUTIONS REQUIRED. Electrical cable compliance Table 1 shows the Compliance Codes for HFAC. The HFAC complies with the requirements covered underUL 1950 third edition and is ...
Page 3 - Table 2. S1 Switch Options (arrow indicates default setting); Switch; REAR VIEW; Figure 3. SW3 Location and Options; indicated in Figure 2.; Unit Options; The locations shown in; Figure 4; are monitored for
3 61221051L1-5, Issue 1 61221051L1-5A Table 2. S1 Switch Options (arrow indicates default setting) Switch Function S1-1 .................................. Errored SecondsDown ................................ Minor AlarmUp (open) ......................... Major Alarm S1-2 ...............................
Page 4 - NOTE: Only one of the S3 Switches should be in the down position.
4 61221051L1-5, Issue 1 61221051L1-5A Table 3. S2 Switch Options (arrow indicates default setting) Switch Function S2-1 ........... S2-2 ............. ES Alarm ThresholdDown ......... Down ............ No AlarmUp (open) .. Down ............ 15Down ......... Up (open) ..... 30Up (open) .. Up (open) ....
Page 5 - Errored Seconds Monitor Locations; HRE
5 61221051L1-5, Issue 1 61221051L1-5A Severely Errored Seconds (SES) Alarm The locations shown in Figure 4 are monitored forSeverely Errored Seconds and counts are maintainedfor each location. If any of these counts exceed theSES programmed threshold (see Tables 1 and 2) analarm will be generated. T...
Page 6 - Function; Disabled
6 61221051L1-5, Issue 1 61221051L1-5A resulting from blown fuses in the HFAC, HTU-C, orHCOT units, or from communications failure betweenany HTU-C and the HFAC. Alarm severity andthreshold value can be provisioned for the erroredsecond, severely errored second, and unavailablesecond parameters. An o...
Page 7 - Figure 6. Control Port Pin Assignments; DTR; FACEPLATE FEATURES; Table 6. HFAC Faceplate Features; Indicators; HFAC
7 61221051L1-5, Issue 1 61221051L1-5A Figure 6. Control Port Pin Assignments (DCE Configuration) 6 7 8 9 1 2 3 4 5 TXD (TXD to DTE) RXD (TXD from DTE) DTR SGN GND DSR RTS CTS interconnect subsequent shelves. Each shelf controllershould be assigned unique sequential shelf addresses.No connection shou...
Page 8 - From the Main Menu select:; HDSL Loops; Figure 7; . This screen includes ADTRAN
8 61221051L1-5, Issue 1 61221051L1-5A technical support phone numbers along with serialnumbers, CLEI codes, date of manufactureinformation for each active HDSL / HDSL2 systemelement, and if the circuit has an installed HDSL /HDSL2 range extender (HRE / H2R). N O T E The command keys valid for each s...
Page 9 - Figure 8. Main Menu Screen; Figure 7. Introductory Menu
9 61221051L1-5, Issue 1 61221051L1-5A Figure 8. Main Menu Screen 08/08/70 17:57:06 SHELF ADDRESS = 00 HFAC MAIN MENU 1: SHELF STATUS SUMMARY 2: PERFORMANCE DATA 3: ALARM STATUS 4: LOOPBACK CONTROL 5: ADTRAN INFORMATION 6: TROUBLESHOOTING 7: SELF-TEST OPTIONS 8: PROVISIONING 9: PROTECTION SWITCHING C...
Page 10 - Shelf Status Summary Screen; The Shelf Status Summary Screen shown in; Figure 9; access Slot 6 information, type; Figure; . This screen gives both local and remote
10 61221051L1-5, Issue 1 61221051L1-5A Shelf Status Summary Screen The Shelf Status Summary Screen shown in Figure 9 provides a top-level look at the alarm andprovisioning of data for the shelf and each circuitwithin the shelf. HDSL / HDSL2 Status Screen From the Shelf Status Summary Screen, detaile...
Page 12 - Figure 11. Shelf Options Setup Screen
12 61221051L1-5, Issue 1 61221051L1-5A Shelf Controller Options From the Shelf Status Summary Screen, all shelfcontroller options may be reviewed. By typing O atthe Shelf Status Summary Screen, the Shelf OptionsSetup Screen may be accessed. This screen isillustrated in Figure 11 . External DSX-1 or ...
Page 13 - Performance History Screen; Slot Specific Performance Data Screen. Performance; Figure 13. Slot Specific Performance Data Screen
13 61221051L1-5, Issue 1 61221051L1-5A Performance History Screen Detailed information concerning 15-minuteperformance history and 24-hour performance historyfor any given slot may be viewed by typing the slotnumber and S from the slot specific Performance DataScreen. The resulting screen is shown i...
Page 14 - Figure 14. Alarm Status Summary Screen
14 61221051L1-5, Issue 1 61221051L1-5A Alarm Status Screen Selection of item 3 from the Main Menu presents theAlarm Status Screen, Figure 14 . This screen is a composite display of all current alarms for each of the13 slots. Alarm types are indicated by the number 1for Critical, 2 for Major, and 3 f...
Page 15 - Loopback Status Summary Screen; illustrates the Loopback; Loopback Options; By pressing a slot number followed by an S from the
15 61221051L1-5, Issue 1 61221051L1-5A Loopback Status Summary Screen Item selection 4, Loopback Control, from the MainMenu displays the loopback status information for allof the HTU-C, HRE, and HTU-R units monitored bythe HFAC. Loopback Status (On, Off, or Notavailable) is presented for loopbacks t...
Page 16 - Troubleshooting Screen; shows the Troubleshooting
16 61221051L1-5, Issue 1 61221051L1-5A Troubleshooting Screen The Troubleshooting Screen (Main Menu, Item 6)provides a graphical presentation of trouble areas.Different parts of the diagram will be highlighted (onterminals that support reverse video) to indicate thetrouble locations. In addition, in...
Page 18 - Provisioning Summary Screen; Enable All; Figure 20. Provisioning Screen
18 61221051L1-5, Issue 1 61221051L1-5A Provisioning Summary Screen Selection of item 8 from the Main Menu suppliesprovisioning information on individual circuits beingaccessed by the HFAC. Figure 20 is a slot-specific provisioning screen showing the provision optionitem, current settings, and hardwa...
Page 19 - Protection Configuration Screen; The protection configuration screens
19 61221051L1-5, Issue 1 61221051L1-5A Protection Configuration Screen The protection configuration screens (Figure 21 and 22) provides status and control details for fault protected circuits. N O T E The screens provided below are typical andmay vary slightly depending on the hardwareinstalled. For...
Page 20 - Table 8. E220 HFAC Specifications; Table 8 lists E220 HFAC specifications.; WARRANTY AND CUSTOMER SERVICE; Carrier Network Equipment; Part Number
20 61221051L1-5, Issue 1 61221051L1-5A Power -48 VDC @ 60 mA (maximum) Physical Dimensions: ............. 5.6" high x 1.25" wide x 10.1" deepWeight: ..................... < 1 pound Temperature Operating: ................ -40 ° C to +70 ° C Storage: .................... -40 ° C to +85 ...