Page 3 - CONTENTS
© Adam Equipment Company 2010 1 CONTENTS 1.0 INTRODUCTION ...................................................................................................... 3 2.0 SPECIFICATIONS .................................................................................................... 4 3.0 INSTALLATIO...
Page 6 - SPECIFICATIONS
© Adam Equipment Company 2010 4 2.0 SPECIFICATIONS CBK 4 CBK 8H CBK 8 CBK 16 CBK 32 CBK 48 Kilograms Maximum Capacity 4 kg 8 kg 8 kg 16 kg 32 kg 48 kg Tare Range -4 kg -8 kg -8 kg -9.9995 kg -32 kg -48 kg Readability 0.0001 kg 0.0001 kg 0.0002 kg 0.0005 kg 0.001 kg 0.002 kg Repeatability (S.D.) 0.00...
Page 10 - PRIMARY FUNCTION; None
© Adam Equipment Company 2010 8 4.0 KEYPAD KEYS PRIMARY FUNCTION SECONDARY FUNCTION [Zero] Sets the zero point for all subsequent weighing. The display shows zero. Escape from any setting menus [Tare] It tares the scale and stores the current weight in memory as a tare value, subtracts the tare valu...
Page 11 - SYMBOLS AND INDICATORS; Net; pcs
© Adam Equipment Company 2010 9 5.0 DISPLAY 6.0 SYMBOLS AND INDICATORS The LCD has unique symbols to indicate the following: 0 The display is at Zero The scale is Stable Net Net weight- The scale has been tared kg / g / lb / oz / lb:oz Symbols shown for the units Capacity Tracker- A bar graph indi...
Page 12 - S3 AoF
© Adam Equipment Company 2010 10 7.0 BATTERY • The scales can be operated from the battery, if desired. The battery life is approximately 90 hours. • When the battery needs charging a symbol on the display will turn on. The battery should be charged when the symbol is on. The scale will still operat...
Page 13 - You can press the [Zero] key at any time to set the zero point; The scale has an automatic re-zeroing function to account for; Manual tare; Place a container on the pan and its weight will be displayed.; Press [Tare] when the reading is stable. The weight that was; As a product is added only the weight of the product will be
© Adam Equipment Company 2010 11 10.0 OPERATIONS 10.1 ZEROING • You can press the [Zero] key at any time to set the zero point from which all other weighing and counting is measured. This will usually be necessary when the platform is empty. When the zero point is obtained the display will show the ...
Page 14 - Preset Tare; Enter a value using the numeric keys.; Press [Tare] to tare the scale. The value that was entered is
© Adam Equipment Company 2010 12 NOTE: When the container is removed a negative value will be shown. If the scale was tared just before removing the container, this value is the gross weight of the container plus all products which were removed. The zero indicator will also be on as the platform is ...
Page 16 - used to change the limits or recall other limits from memory.; Mass on the balance is above the high limit
© Adam Equipment Company 2010 14 • To count a different sample quantity, press the [Count] key. The display will show the last used sample size. Either use this sample size with a different part or enter a new sample size as above. • To return to weighing, press [Unit]. 10.5 CHECK-WEIGHING Check-wei...
Page 17 - Setting up check-weighing while weighing; Setting up check-weighing while parts counting or % weighing
© Adam Equipment Company 2010 15 3. If Limit Password is enabled then enter the password which will allow you to change the limits or the operation of the beeper or bargraph. 10.5.1 Setting up check-weighing while weighing • Press the [Low Limit] key. It will show the current low limit. The “LO” sym...
Page 18 - LIMITS STORING AND RECALLING
© Adam Equipment Company 2010 16 press [CE] to clear the settings, enter zero and then press [Tare] to store the zero values. 10.6 LIMITS STORING AND RECALLING The scale can store up to 10 sets of high and low limits in memory along with the weighing units in use (including pcs for parts counting an...
Page 19 - PERCENT WEIGHING
© Adam Equipment Company 2010 17 NOTE: 1. If the recalled limit is for parts counting, the display will show the last sample value used, ready for a new sample to be counted. 2. If the recalled unit is a percent weighing limit, the display will show the last sample value used, ready for a new sample...
Page 20 - The number of decimal points will depend on the weight used. A; ACCUMULATED TOTAL
© Adam Equipment Company 2010 18 if 3500g is placed on the scale and percent weighing is selected, the display will show 100.00%. Remove the 3500g weight and place a 3000g weight. The display will show 85.7% as 3000g is 85.7% of 3500g. • The number of decimal points will depend on the weight used. A...
Page 21 - Manual Accumulation; ACC 2
© Adam Equipment Company 2010 19 NOTE: 1. The accumulation function is available only during weighing. It is disabled during parts counting or percent weighing. 2. The accumulated weights will be stored in either kg (for g or kg) or lb (for lb, oz or lb:oz). 3. If at any time the weighing units are ...
Page 22 - ACC xx; Automatic Accumulation; ACC x
© Adam Equipment Company 2010 20 • To view the total in memory press the [Print] key when the scale is at zero. The display will show the total number of accumulation " ACC xx " and the total weight before returning to zero. • To print the total, press [Print] to recall and then immediately ...
Page 23 - SERIAL INTERFACE; USB
© Adam Equipment Company 2010 21 11.0 SERIAL INTERFACE The CBK Series are supplied with bi-directional RS-232 interface and an optional USB serial interface as standard. Both interfaces send and receive identical information. See samples below. Specifications: Connector: RS-232 9 pin D-subminiature ...
Page 24 - User ID
© Adam Equipment Company 2010 22 Data Format-Parts Counting Output: Weight, Unit weight and number of parts are printed. Data Format- Memory Recall Output: Data Format- Continuous Output- Normal weighing: Data Format- Continuous Output- Parts Counting: Date 12/09/2006 <cr><lf> Time 14:56...
Page 25 - g for metric and lb for pounds
© Adam Equipment Company 2010 23 LABEL FORMAT = OFF The Output will be what is shown on the display at the time. For example: Data Format-Normal Output: Only weight value along with the weighing unit is printed. If Percent weighing is used then % is shown in place of weighing units. Data Format-Part...
Page 26 - The accumulated total will not be sent to the RS-232 when the; Description; Net weight
© Adam Equipment Company 2010 24 Data Format- Continuous Output- Normal weighing: Data Format- Continuous Output- Parts Counting: NOTE: 1. The accumulated total will not be sent to the RS-232 when the continuous print is turned on. 2. The continuous print will only be for the current weight and the ...
Page 27 - INPUT COMMANDS FORMAT
© Adam Equipment Company 2010 25 11.1 INPUT COMMANDS FORMAT The scale can be controlled with the following commands. Press the [Enter] key of the PC after each command. T<cr><lf> Tares the scale to display the net weight. This is the same as pressing [Tare]. Z<cr><lf> Sets th...
Page 29 - PARAMETER SETTINGS; FUnC 1; CHECK WEIGHING PARAMETERS; F4 bEP
© Adam Equipment Company 2010 27 13.0 PARAMETER SETTINGS Pressing the [Func] key allows the user to access the parameters for customising the scale. The parameters are split into 3 groups- 1. Check weighing parameters, 2. Serial Interface parameters and 3. Scale parameters • When [Func] is pressed, ...
Page 30 - Parameter
© Adam Equipment Company 2010 28 Parameter Description Options Default setting F1 PCt This parameter allows the user to enter the Percent weighing Function. See Section 10.7. None Enabled always F2 LLk This parameter prevents the normal user from changing the limits with the help of a Limit Lock. W ...
Page 32 - CCUMULATION; SCALE PARAMETERS; seconds. The display will go directly to “; Press [Tare] to confirm the change and then advance to the next
© Adam Equipment Company 2010 30 Scale will perform the following, depending on the Accumulation and Print Settings: A CCUMULATION SETTINGS PRINT SETTINGS AC on AC Off AUto Accumulate and print automatically Print again when [Print] key pressed, Print automatically, Do not accumulate Print again whe...
Page 33 - Parameter Description; Calibration
© Adam Equipment Company 2010 31 This group of parameters are used to control the operation of the scale. Parameter Description Options Default setting S1 Un Enable or disable weighing units, will not allow to disable all units, at least one has to be enabled. kg g lb oz lb:oz kg S2 bL Backlight set...
Page 34 - PARAMETER LAYOUT for CBK SCALES; FUNC 1
© Adam Equipment Company 2010 32 14.0 PARAMETER LAYOUT for CBK SCALES Press the [Func] key to enter Functions mode. Key functions while in this section [Tare] enter a parameter or accept the changes [Func] move to next parameter or option [Zero] return to previous parameter or return to weighing FUN...
Page 35 - DESCRIPTION
© Adam Equipment Company 2010 33 15.0 ERROR MESSAGES During the initial power-on testing or during operation, the scale may show an error message. The meaning of the error messages is described below. If an error message is shown, repeat the step that caused the message. If the error message is stil...
Page 36 - REPLACEMENT PARTS AND ACCESSORIES; Main Power cord; SERVICE INFORMATION
© Adam Equipment Company 2010 34 16.0 REPLACEMENT PARTS AND ACCESSORIES If you need to order any spare parts and accessories, contact your supplier or Adam Equipment. A partial list of such items is as follows- • Main Power cord • Replacement Battery • • Stainless Steel Pan • In use cover • Printer,...
Page 37 - WARRANTY INFORMATION
© Adam Equipment Company 2010 35 18.0 WARRANTY INFORMATION Adam Equipment offers Limited Warranty (Parts and Labour) for the components failed due to defects in materials or workmanship. Warranty starts from the date of delivery. During the warranty period, should any repairs be necessary, the purch...
Page 38 - Manufacturer’s Declaration of Conformity; Electro Magnetic Compatibility Directive 2004/108/EC
© Adam Equipment Company 2010 Manufacturer’s Declaration of Conformity This product has been manufactured in accordance with the harmonised European standards, following the provisions of the below stated directives: Electro Magnetic Compatibility Directive 2004/108/EC Low Voltage Directive 2006/95/...