Page 2 - Com AirProtect Sensor 5750 Features; Feature
2 3Com AirProtect Sensor 5750 Features Feature Description 1 Antenna Connectors Two RSMA type antenna connectors allow you to connect antennas that operate in 2.4 GHz and 5.0 GHz bands. 2 LEDs The LEDs indicate power and activity. See “Checking the LED Indicators” on page 8 for details. 3 Ethernet P...
Page 4 - Informacje na temat bezpieczeñstwa
4 Informacje na temat bezpieczeñstwa Urz ą dzenie musi by ć zamontowane zgodnie z lokalnymi i krajowymi normami, ustawami i przepisami. W celu zagwarantowania bezpiecze ń stwa osób i urz ą dze ń , instalacj ę Punktu dost ę pow ę go mo ż e przeprowadza ć wy łą cznie wyszkolony fachowiec ds. sieci. Pr...
Page 5 - Installation Item
5 1. Unpacking the Sensor Make sure that you have the following items, which are included in the package: 2. Preparing for Installation It is advisable to connect the power (if using an external PoE supply) and check the Ethernet cables and LEDs before installing the sensor in a hard-to-reach locati...
Page 6 - Mounting the Sensor; Wall, Ceiling, or Electrical Box Mounting; Wall-mounting the cradle
6 4. Mounting the Sensor The sensor can be mounted on the following types of surfaces: • Wall, ceiling, or electrical box (NEMA enclosure) • Tabletop Wall, Ceiling, or Electrical Box Mounting Use the included mounting bracket to install the sensor on a wall, ceiling, or electrical box. To wall-mount...
Page 7 - Connecting Power and the Network; Power Over Ethernet from a PoE Injector; Sensor
7 5. Connecting Power and the Network The sensor connects to your network through its Ethernet port. This is also how the unit receives power. The sensor can be powered by the following methods: • By Power Over Ethernet (PoE) supplied through the LAN by a 802.3af PoE compliant device such as a switc...
Page 8 - Checking the LED Indicators; Troubleshooting; LED; Power
8 6. Checking the LED Indicators When the sensor is connected to power, LEDs indicate activity as follows: Troubleshooting Refer to the 3Com AirProtect Engine 6100 Configuration Guide for more details on the product. Or visit www.3Com.com. LED Color Indicates Power Steady green Power on, system OK. ...
Page 9 - US — R
9 R EGULATORY I NFORMATION The 3Com AirProtect Sensor 5750, Model WL-548A (3CRWX5750GS) must be installed and used in strict accordance with the manufacturer’s instructions as described in the user documentation that comes with the product. This product contains encryption. It is unlawful to export ...
Page 10 - US M; — RF C
10 The user may find the following booklet prepared by the Federal Communications Commission helpful: The Interference Handbook . This booklet is available from the U.S. Government Printing Office, Washington, DC 20402. Stock No. 004-000-0034504. 3Com is not responsible for any radio or television i...
Page 11 - EU C
11 I NDUSTRY C ANADA - E MISSIONS C OMPLIANCE S TATEMENT This Class B digital apparatus complies with Canadian ICES-003. Avis de Conformité à la Réglementation d'Industrie Canada Cet appareil numérique de la classe B est conform à la norme NMB-003 du Canada. S AFETY C OMPLIANCE N OTICE This device h...