Page 2 - SAFETY PRECAUTIONS; Important Safeguards; Danger
Dinion XF | Installation Manual Bosch Security Systems | 2004-01 | V1.0 EN | 2 SAFETY PRECAUTIONS Important Safeguards 1. Read these instructions.2. Keep these instructions.3. Comply with all warnings.4. Follow all instructions.5. Do not use this equipment near water.6. Clean only with dry cloth.7. ...
Page 3 - Warning
Dinion XF | Installation Manual Bosch Security Systems | 2004-01 | V1.0 EN | 3 9. Do not defeat the safety purpose of the polarized or grounding-type plug. A polarized plug has two blades with one wider than the other. A grounding type plug has two blades and a third grounding prong. Both the wide b...
Page 4 - FCC Information
Dinion XF | Installation Manual Bosch Security Systems | 2004-01 | V1.0 EN | 4 FCC Information This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against har...
Page 5 - Introduction; Type number overview
Dinion XF | Installation Manual Bosch Security Systems | 2004-01 | V1.0 EN | 5 Introduction The Dinion XF Day/Night is a high-performance smart surveillance color camera. It incorporates 15-bit digital signal processing for outstanding picture performance under all lighting conditions. The Dinion XF...
Page 6 - Unpacking
Dinion XF | Installation Manual Bosch Security Systems | 2004-01 | V1.0 EN | 6 Unpacking Unpack carefully and handle the equipment with care. The packaging contains:• DinionXF Day/Night camera • CS to C lens mount adapter • CCD protection cap • Spare lens connector (male) • These instructions Note I...
Page 7 - Connections; Power; Composite video
Dinion XF | Installation Manual Bosch Security Systems | 2004-01 | V1.0 EN | 7 Connections Power Low voltage versions High voltage versions For low voltage cameras:• push in the tabs to open the quick-connectors (these connections are not polarity sensitive). • use AWG16 to 22 stranded wire or AWG16...
Page 8 - Sync
Dinion XF | Installation Manual Bosch Security Systems | 2004-01 | V1.0 EN | 8 Sync Y/C VIDEO SVHS SYNC DC 12VAC 24V ALARM VIDEO SVHS SYNC ALARM VIDEO SVHS SYNC DC 12VAC 24V ALARM VIDEO SVHS SYNC ALARM 1 2 4 3 Pin Y/C socket 1 G ND Y 2 GND C 3 Y 4 C DinionXFD_Nv1_0.book Page 8 Friday, January 7, 200...
Page 9 - Alarm connector; Lens mounting; Alarm
Dinion XF | Installation Manual Bosch Security Systems | 2004-01 | V1.0 EN | 9 Alarm connector • Max. wire diameter AWG 22-28 for both stranded and solid • Default relay position n.o. (normally open), no alarm • Alarm output relay switching capability: Max voltage 30VAC or +40VDC. Max 0.5 A continuo...
Page 11 - Back focus adjustment
Dinion XF | Installation Manual Bosch Security Systems | 2004-01 | V1.0 EN | 11 Back focus adjustment To optimize picture sharpness in both bright and low-level lighting, adjust the back focus. Use the camera's unique Lens Wizard (see Advanced Set- up) . This ensures that the object of interest alwa...
Page 12 - Mounting the camera; Caution
Dinion XF | Installation Manual Bosch Security Systems | 2004-01 | V1.0 EN | 12 Mounting the camera The camera can be mounted from the top or bottom. The bottom mounting is isolated from ground. With outdoor scenes, a DC-iris lens is recommended. Day/Night switching The Dinion XF Day/Night Camera is...
Page 13 - Accessing and navigating menus
Dinion XF | Installation Manual Bosch Security Systems | 2004-01 | V1.0 EN | 13 Advanced Set-up The Dinion XF Day/Night normally provides an optimal picture without the need for further adjustments. However, advanced set-up options are available for getting the best results from the camera under spe...
Page 14 - Menu Structure
Dinion XF | Installation Manual Bosch Security Systems | 2004-01 | V1.0 EN | 14 Menu Structure Mode ModeALCEnhanceColorBLCVMDMode I DDefaultsExit ALC ALC levelShut/GainPeak / averageALC speed Shut/Gain ShutterDefshutSens upGainMax. gainDay/Night ENHANCE AutoblackBlacklevelContourDNRXF-dynamic Day/Ni...
Page 16 - Hints for menu navigation; How to use the 5 keys
Dinion XF | Installation Manual Bosch Security Systems | 2004-01 | V1.0 EN | 16 Hints for menu navigation How to use the 5 keys • Press the menu/select key to access the menus or to move to the next or previous menu. • Press the menu/select key for approximately 1.5 seconds to open the Installer men...
Page 17 - Mode menu; ALC submenu
Dinion XF | Installation Manual Bosch Security Systems | 2004-01 | V1.0 EN | 17 Mode menu ALC submenu Function Selection Description MODE 1, 2, 3 Select operating mode ALC Select submenu Select to access the video level control menu ENHANCE Select submenu Select to access the picture enhancement men...
Page 19 - Enhance submenu
Dinion XF | Installation Manual Bosch Security Systems | 2004-01 | V1.0 EN | 19 Day/Night submenu Enhance submenu Function Selection Description DAY/NIGHT COLOR, MONO, AUTO • In COLOR mode the camera will always give a color image.• In MONO mode the IR filter is removed, giving full IR sensitivity i...
Page 20 - Color submenu
Dinion XF | Installation Manual Bosch Security Systems | 2004-01 | V1.0 EN | 20 Color submenu Back Light Compensation (BLC) submenu Selecting an area To set-up an area for BLC (or VMD), access the area menu by selecting the AREA option from the BLC (or VMD) menu. Upon entering the AREA Function Sele...
Page 21 - Defaults submenu
Dinion XF | Installation Manual Bosch Security Systems | 2004-01 | V1.0 EN | 21 menu, the current area is displayed with the upper left corner f lashing. The f lashing corner of the image can be moved with the Up, Down, Left, Right arrow keys. Pressing the Select key moves the f lashing cursor to th...
Page 22 - Installer Settings; Install menu; Install lens wizard submenu
Dinion XF | Installation Manual Bosch Security Systems | 2004-01 | V1.0 EN | 22 Installer Settings Install menu Install lens wizard submenu Adjustment procedure DC-iris Lens: 1. Unlock the back focus locking button. 2. Access the Lens Wizard menu. 3. SET BACK FOCUS NOW is highlighted in the menu. 4....
Page 24 - Install sync submenu
Dinion XF | Installation Manual Bosch Security Systems | 2004-01 | V1.0 EN | 24 Install I/O --> Alarm submenu Install sync submenu Note VPHASE, HPHASE and SUB-PHASE cannot be accessed if there is no valid locking signal. Function Selection Description ACTIVE NONE, HIGH, LOW Selects active_HIGH or...
Page 25 - Install ID submenu
Dinion XF | Installation Manual Bosch Security Systems | 2004-01 | V1.0 EN | 25 Install ID submenu Defaults submenu Camera Control Communication This camera is equipped with a coaxial communications transceiver. In combination with VP-CFGSFT, the camera can be adjusted from the head-end side of the ...
Page 26 - Technical specification
Dinion XF | Installation Manual Bosch Security Systems | 2004-01 | V1.0 EN | 26 Technical specification 1/2" CCD versions Type number LTC 0620/11 LTC 0620/21 LTC 0620/51 LTC 0620/61 Standard PAL NTSC PAL NTSC Active pixels 752x582 768x492 752x582 768x492 Rated supply voltage 24 VAC or 12 VDC12-2...
Page 28 - Accessories; Power transformers; Recommended lenses
Dinion XF | Installation Manual Bosch Security Systems | 2004-01 | V1.0 EN | 28 Accessories Power transformers • TC1334 120VAC, 60Hz - 24VAC, 30VA • TC120PS 120VAC, 60Hz - 15VDC, 9VA • TC220PSX-24 220-240VAC, 50/60Hz - 24VAC, 30VA • TC220PS 220-240VAC, 50/60Hz - 15VDC, 9VA Interface box: • VP-CFGSFT...