Bosch 17e - Manual
Bosch 17e – Manual, read for free online in PDF format. We hope this helps you resolve any issues you may have. If you have further questions, please contact us through the contact form.
Table of Contents:
- Page 2 – Page Number; INDEX; Installation/Operating Instructions
- Page 5 – TECHNICAL DATA; DATA PLATE; DO NOT OPERATE WITH ANY OTHER GAS TYPE.; WARNING LABELS
- Page 6 – POSITION FOR INSTALLATION; This water heater is approved for outdoor installation only.
- Page 7 – COMPONENT DETAILS
- Page 9 – GAS CONNECTION; thread diameter is 20 mm.; THIS DOES NOT INDICATE THE SIZE OF THE GAS SUPPLY.; COLD WATER CONNECTION TO WATER HEATER; STOP TAPS OR COMBINATION STOP TAPS AND NON-RETURN VALVES ARE
- Page 10 – If the power cord is damaged and; COLD
- Page 11 – TEMPERATURE SELECTOR PAD INSTALLATION DETAILS; Only one of each type can be connected to the appliance.
- Page 12 – TEMPERATURE CONTROL OPERATION; Connect the other end of the cable to the terminals on the PCB.
- Page 13 – SETTING THE TEMPERATURE; Remote controller less
- Page 14 – Step 4: Turn power back on; PCB
- Page 15 – USER SAFETY INSTRUCTIONS; PLEASE CAREFULLY READ THIS USER INSTRUCTION BEFORE USE.; IN CASE OF DIFFICULTIES
- Page 16 – WATER QUALITY; WATER QUALITY TABLE
- Page 17 – consequential losses or other expenses; Warranty conditions
- Page 18 – How to lodge a warranty claim and warranty procedure; will not be accepted for payment by Bosch.; Purpose
1
Installation/Operating Instructions
Invented for life
MODELS
Bosch 17e
Bosch 21e
Bosch 25e
Bosch 26e
(YS1770RA series, YS2170RA series, YS2670RABZ, YS2670RA series)
INSTALLATION MANUAL
This appliance must be installed in accordance with the manufacturer’s installation instructions, AS5601,
AS/NZS3500.4, AS3000 wiring regulations and all Local Building, Water and Gas fitting regulations.
To be installed and serviced only by an authorised person
This appliance is not suitable for use as a pool heater
The “authorised installing person” is responsible for :
1.
Correct commissioning of this appliance.
2.
Ensure unit performs to the specifications stated on the rating label.
3.
Demonstrate operation of unit to customer before leaving.
4.
Hand these instructions to customer.
Failure to install this appliance in accordance with these installation instructions may void warranty
SAR8512-7
Rev. 10/11
*SAR8512 C*
"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.
Summary
2 Page Number INTRODUCTION 3 DIMENSIONS 4 TECHNICAL DATA 5 APPLIANCE LOCATION 6 COMPONENT DETAILS 7 GAS CONNECTION 9 COLD WATER CONNECTION 9 HOT WATER CONNECTION 10 ELECTRICAL CONNECTION 10 PRE-SET TEMPERATURE 10 TEMPERATURE SELECTOR PAD INSTALLATION 11 TEMPERATURE SELECTOR PAD WIRING 11 TEMPERATURE...
5 Installation/Operating Instructions Invented for life TECHNICAL DATA Nominal hourly gas consumption by proportional gas control: 17e 21e 26e 135 Mj/hr 170 Mj/hr 200 Mj/hr 135 Mj/hr 170 Mj/hr 200 Mj/hr Natural Gas LP Gas Test Point Pressure: Maximum Inlet Water Pressure 1000 kPa Input voltage singl...
6 Use as a guide only. Refer to AS5601 or local gas fitting rules for specific locations T=Flue terminalI=Mechanical air inlet M=Gas meter W=Window Shaded area indicates prohibited area P=Electricity meter or fuse box f c n k k j j j h h e T e h T g P W d b d T g c a M door I Ref Item Minimum Clea...