Page 2 - SPECIFICATION; GENERAL
1-2 (No.PA019) SPECIFICATION GENERAL OPTIC ELECTRIC OUTPUT TERMINAL INPUT CONNECTORS TypeDimensions(W × H × D) Mass D-ILA HOME THEATER PROJECTORApprox. 298 mm × 134 mm × 360 mm (Approx. 11-7/8" × 5-3/10" × 14-1/5") (Excluding handle, lens and protrusions) Approx. 6.2kg (Approx....
Page 3 - Power cord
(No.PA019)1-3 SECTION 1 PRECAUTION 1.1 SAFTY PRECAUTIONS Prior to shipment from the factory, JVC products are strictly in- spected to conform with the recognized product safety and elec- trical codes of the countries in which they are to be sold.However,in order to maintain such compliance, it is eq...
Page 5 - avoid electric shock.; WARNING; Class
(No.PA019)1-5 1.1.3 Warning and caution labels • Labels advising of warning and caution are affixed on and in various locations of the product. • Take careful notice of these during service and inspection. 1.1.4 Additional cautionary items • High voltage is applied for lighting the lamp. During adju...
Page 6 - INSTALLATIONS
1-6 (No.PA019) 1.2 INSTALLATIONS 1.2.1 Installation method The D-ILA system (reflecting type active matrix liquid crystal system) does not require convergence adjustment. Note the followingwhen placed on a floor (refer to OPERATING INSTRUCTIONS for actual operating method). (1) Place the projector a...
Page 7 - FUNCTIONS; RIGHT SIDE; POWER INPUT
(No.PA019)1-7 SECTION 2 SPECIFIC SERVICE INSTRUCTIONS 2.1 FUNCTIONS 2.1.1 LED indications The LED operations are as follows. OPERATE LED STAND-BY LED TEMP LED LAMP LED NOTE : Please refer to troubleshooting about the warning display byLED. 2.1.2 Operation button & LED location 2.1.3 Inpu...
Page 10 - Use the following buttons to operate the service menu.; Option SCREEN; SERVICE MENU; SETTING NENU
1-10 (No.PA019) 2.7 SERVICE MENU The service menu contains items not ordinarily needed by the us-er. Use these as necessary during service. 2.7.1 Enter (1) No menu shown.(2) Press the [ ] button. (3) Within press the [ ] button. (4) Within press the [ ] button. (5) Within press the [ ] button. (6) W...
Page 12 - FACTORY SHIPPING SETTING; Lamp time
1-12 (No.PA019) 2.8 FACTORY SHIPPING SETTING SET (PROJECTOR) / REMOTE CONTROL UNIT MAIN POWERVIDEOHIDE Switch / Item OFFVIDEOOFF (display) Position Image adjust Item GammaColor temp. Color temp. RED GREEN BLUETest pattern Menu PositionMaskSource 2.2 D65000 CENTEROff60p Position Item Position ENTER E...
Page 13 - LENS COVER
(No.PA019)1-13 SECTION 3 DISASSEMBLY Notes: • Confirm that the power cord is unplugged from the AC outlet before proceeding.• The lamp remains quite hot after turning the power off. Allow sufficient time to cool before starting work. 3.1 LENS COVER (1) Rotate the LENS COVER on the front of the main ...
Page 14 - TERMINAL BOARD AND SHIELD SHEET
1-14 (No.PA019) 3.6 TERMINAL PWB ASS'Y AND MAIN PWB ASS'Y • Remove the LENS COVER.• Remove the LAMP UNIT COVER.• Remove the TOP COVER. (1) Remove the 6 screws marked J fixing the MAIN PWB ASS'Y. (Fig.3) (2) Remove the harness from the connectors CN710 and CN711 . (3) Remove the cord wire from the co...
Page 15 - fixing the LAMP UNIT UP-; LAMP UNIT UPPER BRACKET
(No.PA019)1-15 3.9 LAMP UNIT UPPER BRACKET • Remove the LENS COVER.• Remove the LAMP UNIT.• Remove the TOP COVER.• Remove the MAIN PWB ASS'Y. (1) Remove the 2 screws marked M fixing the LAMP UNIT UP- PER BRACKET. (Fig.4) (2) Pull out the LAMP UNIT UPPER BRACKET in the direction of the arrow. 3.10 PO...
Page 16 - POWER SUPPLY CONTROL MODULE PWB ASS'Y
1-16 (No.PA019) 3.11 POWER SUPPLY PWB ASS'Y • Remove the LENS COVER.• Remove the LAMP UNIT.• Remove the TOP COVER.• Remove the MAIN PWB ASS'Y.• Remove the LAMP UNIT UPPER BRACKET.• Remove the POWER SUPPLY SHIELD CASE(1). (1) Remove the 4 screws marked P fixing the POWER SUP- PLY PWB ASS'Y. (Fig.5) (...
Page 18 - BEFORE STARTING ADJUSTMENT
1-18 (No.PA019) SECTION 4 ADJUSTMENT 4.1 BEFORE STARTING ADJUSTMENT (1) Adjustment items utilize a personal computer. This instruction is for HD2 PSA CONTROL PROGRAMProgram. Use the latest version program. (2) Data back up is required before adjustments.(3) Allow the equipment and test instruments a...
Page 20 - Instruments
1-20 (No.PA019) 4.4 ADJUSTMENT PROCEDURE 4.4.1 D-ILA COMMON DC adjustment Note : Large deviation of this adjustment can cause image flicker.Residual image or element burn can occur when out of adjustment. PREPARATION (1) Connect the PC and the Projector with an RS 232C cable and turn the projector...
Page 21 - ADJUSTMENT; Adjust here
(No.PA019)1-21 ADJUSTMENT (9) On the [DDIC Control][Flat Field] tag, set the Flat Field Level value for a color to be adjusted to 512 and the rest to 0, respectively. Refer to Fig.3. Fig.3 (10) In the [DDIC Control][EVR] tag, find the point by sliding a CC slider (CC_R for red, CC_G for green and ...
Page 22 - Set these parameters to ON
1-22 (No.PA019) 4.4.2 DC adjustment PREPARATION (1) Connect the PC and Projector, PC and CL200 with RS-232C cables and then turn the Projector ON.(2) Boot the SPA software.(3) Click [Connect] on the Menu Bar and select [Auto Connect] in the pull-down menu. Refer to Fig.1. Fig.1 Fig.2 (4) When the ...
Page 23 - PREPARATION
(No.PA019)1-23 4.4.3 GAMMA adjustment PREPARATION (1) Open the Black (GAMMAOFF) sheet in the GAMMA adjustment file and click [CONNECT] in the same way as the DC adjustment. Refer to Fig.1. (2) On completion of the connection, click [MEASURE]. Refer to Fig.1.(3) On completion of the measurement, cl...
Page 26 - LUM DYN STC Vcom button
1-26 (No.PA019) 4.4.4 SHADING adjustment PREPARATION (1) When the reverse shading function is used, open Menu [DDIC] [FPGA], and set [Left side Right] and [Up SideDown] to [Off]. (2) Open Menu [Area Shading] and, after clicking [LUM]. Set each [R], [G] and [B] to [Default] respectively, then click...
Page 28 - MEASUREMENT; through to the 16th phase.
1-28 (No.PA019) MEASUREMENT (1) Open the previously renamed Excel file and select the [PHS_Rch] sheet.(2) Set the values of the [R[, [G] and [B] scroll bars to [0] in the [DDIC Control][Flat Field] tag in the [DDIC Control] screen. (3) Set the slide switch to [FORWARD] on the Phase Deviation Measu...
Page 29 - Enlarged
(No.PA019)1-29 4.4.6 GHOST adjustment PREPARATION (1) Connect the PC and Projector with a RS-232C cable and turn the Projector ON.(2) Boot the PSA software.(3) Click [Connect] on the menu bar and select [Auto Connect] in the pull-down menu. Refer to Fig.1. Fig.1 Fig.2 (4) When the connection is co...
Page 33 - Click
(No.PA019)1-33 5.3 ERROR LOG (SELF-DIAGONOSIS RECORD AND INDICATION) 5.3.1 Outline By using the special setting and adjustment software, data related to abnormal operation (history) stored in the projector can be load.On the basis of contents "LED (INDICATOR) WARNING INDICATONS" set and lamp...