  • Page 2 – Agency Approvals; ed at time of order.; ed service agency for use in profes-; Do NOT operate the burner beyond speci; cations and agency approvals for veri; Contents
  • Page 3 – Section: General Information; General Information; Failure to follow these instructions could result in
  • Page 4 – Pre-installation Checklist; Combustion Air Supply; Figure 1 – Typical Nameplate; Clearances; If fuel supply is level with or higher than fuel unit —; Figure; When fuel supply is below the burner fuel unit —; cannot; Do not install valves in return line.; Model “XX”; MFR’S SETTINGS
  • Page 5 – Electrical Supply; Verify Burner Components; Verify Firing Rate; Incorrect nozzles and
  • Page 6 – Figure 3a - Firebox Pressure: CF2500A with no Reserve Air; Figure 3b - Firebox Pressure: CF3500 with no Reserve Air; Verify Air Tube; Table 2
  • Page 7 – Table 2 - Air Tube Capacity Versus Firebox Pressure; Maximum Firing Rate GPH; Dust and Moisture; Mount the Burner; Figure 4; Stray Light; Wet, dusty environments could lead to blocked air; Section: Mount the Burner; Overheating could cause damage to the air tube and
  • Page 8 – Install Nozzle Line Assembly; Z Dimensions; cations; Failure to properly maintain these speci
  • Page 9 – Set Dimension Z; do not; Insert Burner; with length 11 inches less
  • Page 10 – Connect Fuel Lines; Fuel Unit By-pass Plug; Section: Connect Fuel Lines
  • Page 11 – Figure 9 – One-pipe Oil Flow; Nozzle Pressure; – The fuel unit nozzle port; to
  • Page 12 – Wire the Burner; Electrical Shock Hazard; Electrical shock can cause severe personal injury or death.; Operation; Section: Wire the Burner
  • Page 13 – Standby; Figure 12 - GeniSys 7505 Control with Optional Components; Flame Detection Range; Limited = 1600 ohms to lockout; Optional Components; Figure 11 - Typical Burner Sequence of Operation - 7505; Cad Cell Resistance Measurement:
  • Page 15 – Initiate
  • Page 16 – Prepare the Burner for; ed service technician who is trained; These covers must be securely in place to prevent
  • Page 17 – Figure 16 – Adjusting Plate Initial Setting, Typical; Z Dimension; Table 6; Dimension Z; ‘Set Z
  • Page 18 – Initial Air Settings
  • Page 19 – Start the Burner; Set Appliance Limit Controls; ‘Start the Burner’; Start Burner and Vent Air from Oil Line; re hold; ‘Initial Air Settings’; use of this burner could result in severe; Explosion and Fire Hazard; Failure to follow these instructions could lead
  • Page 20 – re Air’; re; re Air; Table 4
  • Page 21 – Annual Service; — by quali; Perform Regular Maintenance; Monthly Maintenance; — by owner; Section: Perform Regular Maintenance; Tampering with or making incorrect
  • Page 22 – Replacement Parts; For best performance specify genuine; Beckett; replacement parts; Item Description; Figure 2
  • Page 23 – Figure 18 - Burner Replacement Parts; Flange A
  • Page 24 – Guelph, Ontario N1G 3X7; ts, products must be installed by a; Limited Warranty Information
Loading the manual

COMMERCIAL PRODUCTS

Potential for Fire, Smoke and Asphyxiation Hazards

To the Homeowner or Equipment Owner:

Please read and carefully follow all instructions
provided in this manual regarding your
responsibilities in caring for your heating
equipment.
Contact a professional, quali

fi

ed service agency for

installation, start-up or service work.
Save this manual for future reference.

y

y

y

Incorrect installation, adjustment, or misuse of this burner could result in death, severe

personal injury, or substantial property damage.

To the Professional, Quali

fi

ed Installer or Service Agency:

Please read and carefully follow all instructions provided
in this manual before installing, starting, or servicing this
burner or heating system.
The Installation must be made in accordance with all state
and local codes having jurisdiction.

y

y

"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.

Summary

Page 2 - Agency Approvals; ed at time of order.; ed service agency for use in profes-; Do NOT operate the burner beyond speci; cations and agency approvals for veri; Contents

2 Agency Approvals UL listed to comply with ANSI/UL296 and certi fi ed to CSA B140.0. Accepted by N.Y.C. M.E.A.Other approvals may be available and must be speci fi ed at time of order. ○ ○○ To the Owner: Thank you for purchasing a Beckett burner for use with your heating appliance. Please pay atten...

Page 3 - Section: General Information; General Information; Failure to follow these instructions could result in

3 CF2500/CF3500 Burner Manual Hazard De fi nitions Owner’s Responsibility: Service Agency Responsibility: Section: General Information Indicates a hazardous situation which, if not avoided, will result in death or serious injury. Used with the safety alert symbol, indicates a hazardous situation, wh...

Page 4 - Pre-installation Checklist; Combustion Air Supply; Figure 1 – Typical Nameplate; Clearances; If fuel supply is level with or higher than fuel unit —; Figure; When fuel supply is below the burner fuel unit —; cannot; Do not install valves in return line.; Model “XX”; MFR’S SETTINGS

4 Pre-installation Checklist Combustion Air Supply Fuel Supply Figure 1 – Typical Nameplate The burner requires combustion air and ventilation air for reliable operation. Assure that the building and/or combustion air openings comply with National Fire Protection Standard for Oil-Burning Equipment, ...

Other Beckett Models