Beckett 7600 - Manual
Beckett 7600 – Manual, read for free online in PDF format. We hope this helps you resolve any issues you may have. If you have further questions, please contact us through the contact form.
Table of Contents:
- Page 2 – Features; Technical Speci; This control must be installed, adjusted and put
- Page 3 – Figure 1 - Getting to know the AquaSmart 7600 Series Control; Temperature Ranges and Differentials; Electrical Ratings; 0A (Reduce to 15A if optional; 4 Vac Thermostat Anticipator Current:; Electrical Shock Hazard
- Page 4 – Mounting; When replacing an OEM-installed; Retro; The AquaSmart can be used to; Sensor/Immersion Well Mounting; – This is the; Surface Mounting; – This is sometimes required; Installation; Figure 3 - Mounting Options
- Page 5 – AquaSmart Models and Cross-Reference Guide; Table 1a - Direct Replacements; Table 1b - Functional Replacement; Replacement of the following controls must be done only by a quali
- Page 6 – Table 1b
- Page 7 – toward; Installing the Temperature Sensor; Figure 4a - Installation of Temperature Sensor in Immersion Well; Removing the Control to be Replaced; Figure 4b - Strain Relief; Electrical shock hazard.; fl; t in most
- Page 8 – “LOCKOUT; Only use Te; Permatex; cations
- Page 9 – Remove the green sensor
- Page 10 – Appliance Surface; Installing the AquaSmart Control; Figure 3; Wiring
- Page 11 – Wiring the AquaSmart Control; Water Flow Symbols Key (Figures 12 through 17); - Pressure Regulator; Reversed polarity could cause erratic cycling of the; IMPORTANT: TO PREVENT DAMAGE TO
- Page 25 – A. Temperature High Limit; “HIGH LIMIT”; B. Temperature Low Limit; OPTION; “LOW LIMIT”; OFF; C. Temperature High Limit Differential; OPTION; “HIGH DIFF”; Programming Basic Functions; Figure 18 - AquaSmart Keypad; Electrical Shock Hazard.
- Page 26 – D. Temperature Low Limit Differential; “LOW DIFF”; LOW; B. Viewing the Boiler Cycle History; Programming Additional Options; not; A. Changing the Heat Manager Settings; “OPTION”
- Page 27 – C. Changing the Circulator Settings; OPTION”
- Page 28 – “OPTION; “OPTION
- Page 29 – RESET; “ENTER; DELAY ON
- Page 30 – AquaSmart Operation; System Action; ed. The above procedure helps to verify; Control Checkout Procedure; These procedures are typical for the default con
- Page 31 – How a Boiler Control Works; Figure 19 - Cold Start Operation (Low Limit
- Page 32 – Troubleshooting; Lockout; HeatManager Technology; If the residence is unattended in severely cold; Display Boiler Status Mode; SENSOR ERR
- Page 33 – The 7600 control has no serviceable internal; Before Leaving the Installation Site, Verify:; Service; AquaSmart Remote Mount Unit Pack • 7600RMU
- Page 34 – Notes Section
- Page 35 – Mounting Template; THIS END UP; Use self-drilling screws supplied in the
- Page 36 – Guelph, Ontario N1G 3X7; ts, products must be installed by a; Limited Warranty Information
PARTS & ACCESSORIES
Description / Applications
The Beckett AquaSmart™ is an advanced boiler control designed for use on
residential and light commercial boiler systems. All models include the option of
enabling Beckett HeatManager™ dynamic temperature reset that, when selected,
provides up to 20% fuel consumption savings. The control includes a backlit LCD
digital display with touch pad to easily program temperature limits, differentials,
and other advanced options. The AquaSmart™ also has memory storage of
system history for help with diagnostics and troubleshooting.
"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.
Summary
2 HeatManager™ dynamic temperature reset for additional energy savings — DOE 2012 Compliant — Meets NR CAN proposed 2012 requirements Advanced microprocessor-based design Backlit LCD digital display with installer programming touch pad Quick access to system cycle history Onboard power disconnect sw...
3 AquaSmart Boiler Control Manual Figure 1 - Getting to know the AquaSmart 7600 Series Control Temperature Ranges and Differentials High Limit Setting Range: 100 to 240°F (37 to 115°C)High Limit Differential Range: 5 to 45°F (2 to 25°C)Low Limit Setting Range: 100 to 220°F (37 to 104°C)Low Limit Dif...
4 Figure 2 - Basic Dimensions (inches) Mounting OEM Installation: When replacing an OEM-installed AquaSmart, consult the appliance manufacturer’s wiring diagrams and instructions for additional information. Retro fi t Installation: The AquaSmart can be used to replace most standard boiler temperatur...