Beckett 7559 - Manual
Beckett 7559 – Manual, read for free online in PDF format. We hope this helps you resolve any issues you may have. If you have further questions, please contact us through the contact form.
Table of Contents:
- Page 2 – Table 1 - Model Guide; Features; Electrical Ratings; Do Not Use This Control; CAUTION; A low or erratic power supply could; Maintain Speci; Special Note: The 7559 Control; WARNING; Environmental Ratings:; NOTICE
- Page 3 – Electrical Shock; fl
- Page 4 – Figure 1 – Getting to know the control
- Page 5 – Starting the System; Priming the Pump; Incorrect Wiring Will; Refer to the steps for; Starting the
- Page 6 – Sequence of Operation; Burner States; Standby; Reset and Service by Quali; Fire Hazard
- Page 7 – tting and fully opening; Resetting From Lockout; Failure to bleed the pump properly could; Heavy Smoke Hazard; Before starting or resetting; Hazard; Checkout
- Page 8 – ts, products must be; Limited Warranty Information
GeniSys
™
24V
Model 7559
Advanced 24 Vdc Burner Control
Description / Applications
The Beckett GeniSys
TM
24V Advanced Burner Control is a
24 Vdc primary safety control for oil burners used in special
applications including, but not limited to, water heaters,
pressure washers, crack sealers and portable heaters having
fi
ring rates less than 5.5 GPH. The GeniSys
TM
24V is used
with a suitable cad cell
fl
ame sensor to control the oil burner
motor, igniter, and optional solenoid valve. It has 24 volt enable
input compatible with mechanical and high limit switches. It
can provide interrupted or intermittent duty ignition, and it has
a 15 second lockout time on
fl
ame failure.
PARTS & ACCESSORIES
"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.
Summary
2 Table 1 - Model Guide Beckett GeniSys 24V Control Part No. Lockout Time Valve-on delay time 1 Motor- off delay time 1 7559A 0000 1 15 sec 0 sec 0 sec 7559P 1530 1 15 sec 15 sec 30 sec 7559P 152M 1 15 sec 15 sec 2 min 7559P 158M 1 15 sec 15 sec 8 min 1 Valve-on delay and motor-off delay timings on ...
3 GeniSys Control 24V Control Installation and Operation Manual Electrical shock can cause severe personal injury or death. Electrical Shock Hazard Disconnect ALL electrical power to the equipment/burner circuit before installing or servicing this control.Provide ground wiring to the equipment, burn...
4 Figure 2 – Typical Wiring for Interrupted Ignition (With or without Valve-on Delay or Motor-off Delay.) Figure 1 – Getting to know the control SK10048 24V POWER MAIN ALARM VALVE GND (VLV) IGNITER GND (IGN) MOTOR GND (MTR) ENABLE CAD CELL ON/OFF/RESET HIGH LIMIT MOTOR IGNITER THERMOSTAT CAD CELL RE...