Page 3 - Safety; Contact Information
Australia/New Zealand This digital equipment fulfills the requirementsfor RF emission according to the Class B limit ofAS/NZS CISPR 22. The product shall be connectedusing a shielded network cable (STP) that is properlygrounded. Korea 이 기기는 가정용(B급) 전자파적합기기로서 주로 가정에서 사용하는 것을 목적으로 하며, 모든 지역에서 사용할 수 있습...
Page 5 - AXIS T90B Series; Safety Information; Hazard Levels; DANGER; NOTICE; Other Message Levels; Important
AXIS T90B Series Safety Information Read through this Installation Guide carefully before installing the product.Keep the Installation Guide for future reference. Hazard Levels DANGER Indicates a hazardous situation which, if notavoided, will result in death or serious injury. WARNING Indicates a ha...
Page 6 - Safety Instructions; WARNING; Transportation
AXIS T90B Series Safety Instructions WARNING • The Axis product shall be installed by a trained professional. NO NO NOTICE TICE TICE • The Axis product shall be used in compliance with local laws and regulations. • Store the Axis product in a dry and ventilated environment. • Avoid exposing the Axis...
Page 7 - Installation Guide; Installation Steps
AXIS T90B Series Installation Guide This Installation Guide provides instructions for installing AXIS T90B Series. Installation Steps 1. Make sure the package contents, tools and other materialsnecessary for the installation are in order. See page 7 . 2. Study the hardware overview. See page 8 . 3. ...
Page 8 - Hardware Overview; Illuminator; Photocell
AXIS T90B Series Hardware Overview Illuminator 1 2 3 1 Photocell 2 Cable 3 Breather gland 8
Page 10 - Red LED indicator
AXIS T90B Series 1 2 3 4 5 1 Red LED indicator 2 Amber LED indicator 3 Green LED indicator 4 Remote control receiver 5 Mounting bracket (pre-mounted) 10
Page 11 - Cables; Optional Accessories; Remote Control; For information how to use the remote control, see
AXIS T90B Series AXIS T90B40 IR-LED 1 2 3 1 Cables 2 Mounting bracket (pre-mounted) 3 Bolt Optional Accessories Remote Control For information how to use the remote control, see Access the Product . 11 E N G L IS H
Page 12 - Mounting Brackets
AXIS T90B Series 1 2 3 4 5 6 7 8 9 1 POWER ADJUST buttons 2 PHOTOCELL ADJUST buttons 3 TIMER buttons 4 Photocell disable button 5 DIM button 6 RESET button 7 STATUS button 8 Disable remote control setup button 9 TELEMETRY button Mounting Brackets To install the product using a compatible bracket fro...
Page 13 - LED Indicators; Programming Mode; Normal Operating Mode; LED Indicator
AXIS T90B Series LED Indicators There are three colored LED indicators on the base of the illuminator whichprovide operating and status information. The color status depends on the current operating mode: • Programming Mode • Normal Operating Mode Programming Mode LED Indicator Indicated Behavior So...
Page 14 - Connectors and Buttons; Power Connector; Specifications; Operating Conditions; Power Consumption; Product
AXIS T90B Series Normal Operating Mode (Continued) Solid Amber Input voltage level error* Solid Red Internal LED error *Once the voltage error has been corrected, disable the remote controlsetup or restart the illuminator to turn the status LED off. Connectors and Buttons For specifications and oper...
Page 15 - For more information about power consumption, see; Install the Hardware
AXIS T90B Series AXIS T90B25 W-LED 12–24 V AC/DC, max 24 W AXIS T90B30 IR-LED 12–24 V AC/DC, max 48 W AXIS T90B35 W-LED 12–24 V AC/DC, max 48 W AXIS T90B40 IR-LED 12–24 V AC/DC, max 96 W For more information about power consumption, see Technical Specifications on page 29 Install the Hardware To ins...
Page 16 - CAUTION; IR emitted from this product. Avoid prolonged eye exposure or
AXIS T90B Series CAUTION IR emitted from this product. Avoid prolonged eye exposure or use appropriate shielding or eye protection at distances of lessthan 1.5 m. Follow these installation procedures: 1. If required, remove the screws and move the standard bracketto the top of the illuminator. 2. If...
Page 17 - Technical
AXIS T90B Series 3. If required, loosen the screws and change to a diverginglens with the desired angle of illumination. The angle ofillumination should be adjusted according to the camera fieldof view to light the whole scene adequately. See Technical Specifications . 17 E N G L IS H
Page 18 - Screws
AXIS T90B Series 2 1 1 Screws 2 Diverging lens Note Adjust the vertical position of the illuminator to ensure that thefield of view of the camera is illuminated. 18
Page 19 - Position the illuminator adjacent to the camera and point the; Mount the power supply.
AXIS T90B Series 4. Position the illuminator adjacent to the camera and point the illuminator towards the scene. CAUTION Red cable = +ve, Black cable = - ve (polarity sensitive) 5. Mount the power supply. 6. Connect the illuminator to the power supply. 19 E N G L IS H
Page 20 - Access the Product; The illuminator has the following default settings:
AXIS T90B Series 2 3 1 1 Illuminator 2 Power cable 3 Power supply 7. Set photocell following output (White & Yellow) Volt freeoutput — normally open (day) to normally closed (night).Connect direct to camera if required to control switchoverof day/night cameras. Access the Product Programming Mod...
Page 22 - Power Adjust; Note
AXIS T90B Series Power Adjust The power output of the illuminator can be adjusted between five pre-setlevels. Select the required light intensity by using the buttons below. 1 2 3 4 5 1 20% of maximum 2 40% of maximum 3 60% of maximum 4 80% of maximum 5 100% of maximum Photocell Sensitivity Note Whe...
Page 23 - Photocell disabled; Telemetry Input
AXIS T90B Series There are three pre-defined levels to set the lux level threshold at which the photocell turns the illuminator on or off. Select the required sensitivitylevel by using the buttons below. 1 2 3 4 1 Photocell disabled 2 5 Lux On, 15 Lux Off 3 10 Lux On, 30 Lux Off 4 25 Lux On, 50 Lux ...
Page 24 - The mode of operation is selected by using the remote control.
AXIS T90B Series Volt-free input: Non polarity sensitiveShort circuit = Light on TTL input: Orange = TTL +vePurple = TTL - ve (GND) 0 V = Light on3 V = Light off The telemetry input wires (orange and purple) are soldered togetherwhen shipped from the factory to simulate a volt-free input so that the...
Page 25 - Turn the light on and off from a remote switch or input.; Timer
AXIS T90B Series 1. Turn the light on (night) and off (day) automatically via the photocell. This is the standard factory setting, no furtheraction is required. 2. Turn the light on and off from a remote switch or input. 3. Used in conjunction with the Timer Function to turn the lighton for a pre-de...
Page 26 - under standard telemetry conditions, press Timer Disabled.; LED Status Indicators
AXIS T90B Series If you wish to cancel the timer period and have the illuminator operate under standard telemetry conditions, press Timer Disabled. 1 2 3 4 5 6 1 Timer disabled 2 1 minute 3 3 minutes 4 10 minutes 5 30 minutes 6 TEL button LED Status Indicators This status indicator function can be s...
Page 27 - Factory Default; Disable Remote Control Setup; Troubleshooting; Ensure all tests are undertaken by a qualified, trained engineer.
AXIS T90B Series Factory Default Note To activate this feature the button must be pressed continuouslyfor 4 seconds. This is to avoid the possibility of activating thisfeature accidentally. Once the illuminator has been programmed, the settings will be stored in anon-volatile (stored) memory. These ...
Page 28 - Basics; Check the LED status indicator. See; Lamp Test; Set up Camera, Lens and Illumination; Make sure the power is set to maximum.
AXIS T90B Series • Basics - Check the LED status indicator. See LED Indicators . - Check polarity of lamp connection: red = +ve,black = -ve - Ensure power is 12-24 V AC or DC - Ensure telemetry wires are shorted out or closedcontact input (zero volt) is applied - Check photocell is working. Cover ph...
Page 29 - Technical Specifications; Models
AXIS T90B Series • Remote Control (optional accessory) - Press the STATUS button to check the status of theremote control, see LED Status Indicators . - Programming may be disabled. Turn the illuminatorpower off for at least 10 seconds and then turn thepower on to enter Programming Mode. - In bright...
Page 30 - Power
AXIS T90B Series Power Input Voltage: 12-24 V AC/DCAC Frequenzy: 50-60 HzCable length 2.5 m (8 ft) Power Consumption maximum light / 20% ofmaximum light / Standby mode:AXIS T90B15 W-LED: 12 W / 3 W / 0.15 WAXIS T90B25 W-LED: 24 W / 6 W / 0.15 WAXIS T90B35 W-LED: 48 W / 12 W / 0.15 WAXIS T90B20 IR-LE...
Page 31 - Distance
AXIS T90B Series Distance AXIS T90B20 IR-LED 10°x10° - 120 m (394 ft)*35°x10° - 65 m (213 ft)60°x25° - 45 m (148 ft) 80°x30° - 30 m (98 ft)120°x50° - 20 m (66 ft)** AXIS T90B30 IR-LED 10°x10° - 220 m (722 ft)*35°x10° - 120 m (394 ft)60°x25° - 65 m (213 ft)80°x30° - 45 m (148 ft)120°x50° - 30 m (98 f...
Page 32 - LED indicators
AXIS T90B Series 80°x30° - 30 m (98 ft) 120°x50° - 20 m (66 ft)** *No diverging lens**Optional accessory Casing Material: PolycarbonateIR-LED: BlackW-LED: White and silver Display and indicators LED indicators Environment Outdoor Mounting WallCeilingColumnCamera housing Approvals EN 55022 Class B, E...
Page 33 - Weight; Further Information; Visit Axis learning center
AXIS T90B Series Dimensions (HxWxL) The size of the product shall be maximum(WxHxL):AXIS T90B15 W-LED: 75 x 100 x 64 mm (3 x4 x 2.5 in) AXIS T90B25 W-LED: 100 x 135 x 66 mm (4 x5 x 2.5 in)AXIS T90B35 W-LED: 135 x 180 x 68,2 mm (5 x7 x3.2 in)AXIS T90B20 IR-LED: 100 x 135 x 66 mm (4 x5 x 2.5 in)AXIS T...
Page 34 - Warranty Information
AXIS T90B Series Warranty Information For information about Axis’ product warranty and thereto relatedinformation, see www.axis.com/warranty/ 34