Page 3 - Store the Axis product in a dry and ventilated environment.; Transportation
EN GL IS H Safeguards Please read through this Installation Guide carefully before installing the Axis product. Keep the Installation Guide for further reference. • Store the Axis product in a dry and ventilated environment. • Avoid exposing the Axis product to vibration, shocks or heavy pressure. D...
Page 5 - GL; AXIS Electrical Safety Kit A/B; Installation steps; Item
AXIS Electrical Safety Kit A/B Page 5 EN GL IS H AXIS Electrical Safety Kit A/B Installation Guide This Installation Guide provides instructions for installing AXIS Electrical Safety Kit A 120 V AC and AXIS Electrical Safety Kit B 230 V AC in AXIS T98A-VE Surveillance Cabinet Series. The purpose of ...
Page 6 - Surge protector 4 A
Page 6 AXIS Electrical Safety Kit A/B Hardware Overview In this document PE, Protective Earth, and Ground are referred to as ground. 1 2 3 4 5 7 6 1 MCB fuse 4 A (Circuit breaker) 2 Surge protector 4 A 3 Terminal block – feed-through (blue) 4 Terminal block – ground (green/yellow) 5 Terminal block –...
Page 7 - Connection Diagram
AXIS Electrical Safety Kit A/B Page 7 EN GL IS H Connection Diagram • If an external protective bonding wire is used it is recom-mended to have a miminum area of 6 mm 2 (AWG 10) for indoor use and a minimum area of 10 mm 2 (AWG 8) for outdoor use. • The circuitry shall be connected to an external do...
Page 8 - Replace the Surge Protector,
Page 8 AXIS Electrical Safety Kit A/B • Check the surge protector after lightning strikes and replace if required. See Replace the Surge Protector, on page 14. • An additional fuse may be required in regions with severe light-ning strikes. To prevent unwanted triggering of the fuse, a higher rated f...
Page 9 - Install the Devices; Snap on the fuse, surge protector and terminal blocks on the DIN
AXIS Electrical Safety Kit A/B Page 9 EN GL IS H Install the Devices • The electrical connections and conduit installations shall be made by a certified electrician and in compliance with local regulations. • Risk of electric shock. The mains supply shall be disconnected during installation. • Keep ...
Page 11 - Example: AXIS Electrical Safety Kit B 230 V AC
AXIS Electrical Safety Kit A/B Page 11 EN GL IS H Example: AXIS Electrical Safety Kit B 230 V AC PE 1 0 L N 4 A 1 6 7 9 8 2 3 4 5 1 Circuit breaker 2 Surge protector 3 Terminal block – feed-through (blue) 4 Terminal block – ground (green/yellow) 5 Terminal block – ground (green/yellow) 6 L Line conn...
Page 12 - Install the Door Switch
Install the Door Switch The door switch included with the electrical safety kit can be connected to the I/O port on a camera or an I/O device. See the camera’s Installation Guide and User Manual for information about connecting and configuring the camera’s I/O port. 1. Connect either of the connecto...
Page 13 - If connecting to the I/O port on a camera, route the door switch
AXIS Electrical Safety Kit A/B Page 13 EN GL IS H 4. If connecting to the I/O port on a camera, route the door switch cable through a cable gasket and attach the cable gasket to one of the cable holes in the cabinet door. 5. Secure the cable to the door using the supplied cable clip.6. Connect the d...
Page 14 - When the entire window is red, pull out the module and replace it.
Page 14 AXIS Electrical Safety Kit A/B Replace the Surge Protector The surge protector gets worn out by surges. The window on the surge protector shows the status of the device. 1. When the entire window is red, pull out the module and replace it. on res alarm on res alarm
Page 15 - Technical Specifications; General
AXIS Electrical Safety Kit A/B Page 15 EN GL IS H Technical Specifications General Function/group Item Specifications General Environment In a casing for indoor or outdoor use Pollution Degree 2 Door switch Approvals EN61058UL1054 Operating conditions -40 ºC to +85 ºC (-40 ºF to 185 ºF)Humidity 15 –...
Page 16 - Rated current
Page 16 AXIS Electrical Safety Kit A/B AXIS Electrical Safety Kit A 120 V AC Function/group Item Specifications Circuit breaker/fuse Rated current 4A at 30°C (86°F) Operating voltage Max 277 V AC Rated frequencey 50/60 Hz Rated short-circuit capacity 10 kA Tripping curve K Approvals IEC/EN 60947-2UL...
Page 17 - AXIS Electrical Safety Kit B 230 V AC
AXIS Electrical Safety Kit A/B Page 17 EN GL IS H AXIS Electrical Safety Kit B 230 V AC Function/group Item Specifications Circuit breaker/fuse Rated current 4A at 30°C (86°F) Operating voltage Max 253 V AC Rated frequencey 50/60 Hz Rated short-circuit capacity 6 kA Tripping curve C Approvals IEC/EN...