1 Page 1
2 Page 2
3 Page 3
4 Page 4
Page: / 4
Loading the manual

TI034-3W

400-034-001-D 13/3/07 1/2

The TI034-3W switch can be used in a single-pole or 3-way installation with the fol-
lowing types of lighting:

• Incandescent
• Halogen
• Low-voltage halogen with transformer
• Fluorescent

The TI034-3W switch cannot be used with a load below 40 W or above 500 W.

n

Cut power at the circuit breaker to avoid electric shock.

o

Remove the existing switch. (For a 3-way installation, identify and label the
wire that is connected to the “common” screw.)

p

Install the new switch (refer to the appropriate section below).

q

Apply power at the circuit breaker.

SINGLE-POLE INSTALLATION

Connect wires "2" and "C" of TI034-3W to the line (120 V) wire.

EXISTING 3-WAY INSTALLATION

Connect wire "C" on the TI034-3W to the "common" wire, identified when removing the
old switch. Connect the other two TI034-3W wires to the two remaining wires.
At the other 3-way switch, connect the jumper wire between the "common" screw and the
screw where wire "1" of the TI034-3W is connected.

NEW 3-WAY INSTALLATION

The jumper wire is not required in this installation. A single-pole switch can be used as
the other switch in a 3-way installation.

n

Pry the switch door open from the bottom
using a small screwdriver.

o

Ensure the

ON/OFF

selector is set to ON.

p

Reset the switch using a paper clip.

0:00

will

flash.

If the display is blank:

Ensure the

ON/OFF

selector is properly

engaged in the

ON

position. Push it to the right

using a small screwdriver.

If the programmable switch controls a lamp equipped with a built-in On/Off switch,
ensure the lamp switch is set to On.

Ensure the light bulb is not burned out and is tightly screwed in its socket..

EXISTING 3-WAY INSTALLATION

If either switch does not work properly, rewire the jumper between the "common"
screw and the other screw.

WARNING

: Before replacing the light bulb, place the

ON/OFF

selector in the

OFF

position. Failure to do so might damage the switch.

The programmable switch has 2 operating modes: manual (

MAN

) and automatic

(

AUTO

). To switch mode, press the switch for 3 seconds.

Manual Mode

The programmable switch operates as a regular switch. Briefly
press the switch door to turn the lights On or Off. The mode
(

MAN

)

and state (

ON

or

OFF

) are displayed.

Automatic Mode

The programmable switch follows the programmed schedule.
The mode (

AUTO

), state (

ON

or

OFF

) and current program

number are displayed.
To temporarily override the programmed schedule, briefly
press the switch door. The new state (

ON

or

OFF

) will flash to

show that the state is temporary. The override remains in effect
until you press the switch door again or until the beginning of
the next program.

NOTE

: The switch displays the time in 24-hour format by default or following a

reset.

n

To switch between 12-hour format and 24-hour format, proceed as follows:
a)

Press one of the control buttons to ensure the

MAN

or

AUTO

indicator is dis-

played.

b)

Press the

MIN

and

HOUR

buttons simultaneously and brieftly (

0:00

display =

24-hour;

12:00

display = 12-hour ).

o

Set the time using the

HOUR

and

MIN

buttons. For the 12-hour time format, if you

are setting an afternoon time, ensure

PM

appears on the screen.

p

Press one of the control buttons or close the switch door to return to normal opera-
tion.

This procedure configures the switch in daylight savings time or in normal/standard
time.

n

Press the

CODE

button four times.

o

Press the

MIN

button to switch between

nor

and

Ad

.

p

Press one of the control buttons or close the switch door to return to normal opera-
tion.

n

Applications

1.

o

Installation

2.

NOTE A : The white wire is not the neutral wire but the wire going to the load.

Line

Neutral

See NOTE A

120 VAC

Line

Neutral

120 VAC

Red

Jumper

Red

3-wire cable

See NOTE A

120 VAC

120 VAC

See NOTE A

p

Power-on

3.

q

Selecting the Operating Mode

4.

r

Setting the Clock

5.

s

Daylight Savings Time

6.

nor

Standard time / Normal time / Winter time

Ad

Daylight savings time / Advanced time / Summer time

Control (4)

Reset

On/Off
selector

TI034-3W

Installation and User Guide

Programmable Wall Switch

"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.

Other Aube Models

All Aube Other