Aube TH146-P-2H1C - Manual
Aube TH146-P-2H1C – Manual, read for free online in PDF format. We hope this helps you resolve any issues you may have. If you have further questions, please contact us through the contact form.
Table of Contents:
- Page 2 – Heating/Cooling System
- Page 3 – New Installation; Principles of Operation; Automatic Heating/Cooling Changeover
- Page 4 – Wiring Tables
- Page 5 – Wiring Diagram: 2H1C Heat Pump — New Installation
- Page 6 – Wiring Diagram: 2H1C Heat Pump — Add-on Installation
- Page 7 – Wiring Diagram: 1H1C HVAC
- Page 8 – Configuration Menu
- Page 9 – User’s Guide; Programmable H/C Controller; Clock and Day Setting; Temperature Setting; Display
- Page 10 – Temperature Adjustment; Unoccupied Mode
- Page 11 – Technical Specifications
TH146-P-2H1C
400-280-014-A 5/23/07 1/11
TH146-P-2H1C
Installation Guide
Programmable 2H1C Controller
The TH146-P-2H1C programmable controller can be used with any
of the following heating/cooling systems:
Heat pump - 1H1C, 2H1C
HVAC - 1H, 1C, 1H1C
The following devices can be connected to the controller:
air recirculation fan
humidifier
dual-register meter (dual energy)
remote control device (for the unoccupied mode)
• CT280-2H1C control module
• TH146-P console with two wall anchors and mounting screws
• AC144-03 outdoor temperature sensor (3 m or 10 ft) with mount-
ing clip (see section 2.6)
• RC845 relay (see section 2.4)
• AC146-410 plenum temperature sensor (see section 2.7)
• CT241 telephone controller (see section 2.9)
• AC130-12 wall plate
Configure the control module according to your type of heating/cool-
ing system using DIP switches on the back of the module.
Install the control module near the heating/cooling system, away
from any heat source.
Install the console in a central location. Avoid locations with air
drafts (e.g., top of staircase or air outlet) or stagnant air (behind a
door). Do not install the console on a wall hiding air ducts nor
expose it to direct sunlight.
NOTE: If this controller replaces an old thermostat, any two of the
wires that were connected to the thermostat can be used to connect
the user console to the control module. The maximum wiring length
is 30 m (100 ft).
CT280-2H1C Control Module
TH146-P User Console
AC144-03 Outdoor
Temperature Sensor
Removable
Connector *
Removable
Connector *
* To remove a connector from the control module, pry with a screwdriver.
1. Introduction
1.1
Applications
1.2
Supplied Parts
1.3
Accessories
2. Installation
2.1
Control Module (CT280-2H1C)
2.2
User Console (TH146-P)
400-280-014-A (TH146-P-2H1C) ENG.fm Page 1 Wednesday, May 23, 2007 4:12 PM
"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.
Summary
TH146-P-2H1C 400-280-014-A 5/23/07 2/11 n Choose a location about 1.5 m (5 ft) above the floor on an inside wall. o Loosen the captive screw under the console. p Detach the console from its base by pulling the bottom section. q Secure the base using the wall anchors and screws. r Connect the console...
TH146-P-2H1C 400-280-014-A 5/23/07 3/11 With automatic heating/cooling mode changeover, there’s no needto adjust the controller at every change of season or weather condi-tion. The controller switches automatically between heating modeand cooling mode to maintain the desired temperature. Manual Mode...
TH146-P-2H1C 400-280-014-A 5/23/07 4/11 Wiring Tables Heat Pump Terminal Device 1H1C 2H1C TH Console Connect the console between the TH terminals (no polarity) TH PS Plenum sensor Connect the plenum sensor between the PS and CS terminals (no polarity) CS Common S Common terminal for the plenum senso...