Table of Contents:

  • Page 2 – INSTAllATION; locked out and only the heat pump will be used to
  • Page 3 – Do not mount remote sensor:; Remote temperature sensor should be mounted:; . Pull wires through the opening on the back of the; pOwER & RESET OpTIONS; system fault and emergency heat indicators to operate .
  • Page 4 – wIRINg TERMINAl; 8-24 gauge thermostat wire; – Fan; O and B terminals are both de-energized when system mode is; CONVENTIONAl HEAT/COOl
  • Page 5 – HEAT pUMp; “O” is active in cooling and “B” is active in heating.; INSTAllER SETUp MENU; to adjust the setting.
  • Page 6 – bold; . Some settings are; INSTAllER SYSTEM SETTINgS TAblE
  • Page 8 – Cooling equipment test; press; to change to the next test
  • Page 9 – SYSTEM TEST TAblES; Heating Equipment Test
  • Page 10 – HEAT pUMp MODE ONlY; QUICK REfERENCE TO CONTROlS & DISplAY; HOME SCREEN
  • Page 11 – Error code
  • Page 12 – Thermal; SpECIfICATIONS; Electrical; THERMOSTAT fEATURES; © 2010 Aprilaire – A division of Research Products Corporation
Loading the manual

READ AND SAVE THESE INSTRUCTIONS

Safety &

Installation

Instructions

Model 8600 Universal

Touch Screen Thermostat

Installation location recommendations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2
Outdoor temperature sensor (optional) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2
Remote temperature sensor (optional) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3
Thermostat mounting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3
Power & reset options . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3
Wiring terminal . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4
Wiring diagrams . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-5

TAblE Of CONTENTS

INSTAllATION

SETUp & TESTINg

REfERENCES

Equipment type selection switch (SW1) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5
Installer setup menu . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5
System test menu . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .8

Quick reference to controls & display . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .10
Troubleshooting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .11
Error codes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .11
Thermostat features . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .12
Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .12

61000729A 8600 Tstat Install.indd 1

10/8/10 10:32:26 AM

"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.

Summary

Page 2 - INSTAllATION; locked out and only the heat pump will be used to

2 INSTAllATION INSTAllATION lOCATION RECOMMENDATIONS Thermostat should be mounted: • On an interior wall, in a frequently occupied space.• Approximately 5‘ above floor.• At least 18” from outside wall.• Thermostat can be mounted to a vertical junction box. Do not mount thermostat: • Behind doors, in...

Page 3 - Do not mount remote sensor:; Remote temperature sensor should be mounted:; . Pull wires through the opening on the back of the; pOwER & RESET OpTIONS; system fault and emergency heat indicators to operate .

3 REMOTE TEMpERATURE SENSOR (OpTIONAl) A remote temperature sensor can be used if the thermostat has to be mounted in a concealed location. A 8051 flush mount or 8053 surface mount remote temperature sensor can be attached to the T1 and T2 terminals and mounted in a recommended area . The remote sen...

Page 4 - wIRINg TERMINAl; 8-24 gauge thermostat wire; – Fan; O and B terminals are both de-energized when system mode is; CONVENTIONAl HEAT/COOl

4 wIRINg TERMINAl wire specifications: 18-24 gauge thermostat wire Installation notes: • Ensure power at the HVAC equipment is off. • Loosen screw terminals, insert stripped wire and re-tighten . • Push the excess wire back into the opening and plug the wall opening to prevent drafts. INSTAllATION C...