Thank you for purchasing APC’s Line-R Automatic Voltage Regulator! Please fill out and

mail the product warranty registration form, or fill out an online form at www.apc.com.

The Line-R automatically corrects brownouts (by boosting low voltage) and overvoltages (by

stepping down high voltage) from the power utility service to levels that are safe for computers,

as well as other sensitive equipment. APC’s Line-R provides the highest degree of protection

from line voltage sags and swells, and has been designed for many years of reliable,

maintenance-free service.

Applications

CAUTION:

The total power consumption of all equipment plugged into the Line-R must not

exceed the “Maximum Output Power Capacity” rating listed in the

Specifications

table. A total

load in excess of th

i

s rating will cause the power switch/circuit breaker to “trip”.

The Line-R is designed for use with voltage sensitive equipment such as a

:

computer, monitor,

inkjet printer, scanner or fax. It is also designed for use with home electronics (TVs, stereos,

CD players, etc.).
Appliances not suitable for use with the Line-R are items such as refrigerators, freezers, power

tools, air conditioners, dehumidifiers, blenders, or any device that employs an AC motor for

operation. Not for use with life sustaining equipment and any device with a power requirement

exceeding the “Maximum Output Power Capacity” rating listed in the

Specifications

table.

Features

ON/OFF Power Switch/Circuit Breaker

The Line-R provides an ON/OFF power switch/circuit breaker which functions as the master

power switch for the Line-R and all devices connected to the device. It also functions as a

circuit breaker to protect the unit from being overloaded. If the circuit breaker “trips”, unplug

the last device connected to the unit, turn the power switch/circuit breaker to the OFF position,

place the power switch/circuit breaker to the ON position.

w

w

w.apc.com

®

Line-R

®

Automatic Voltage Regulator

Models LE600 and LE1200

Lights when input voltage is high.

Flashes when input voltage is above rated Input
Voltage Range.

Input voltage is normal.

Lights when input voltage is low.

Flashes when input voltage is below rated Input
Voltage Range.

ON/OFF Power Switch/Circuit Breaker applies and
removes power to/from the Line-R. This switch also
functions as a circuit breaker in the event of an
over-load condition.

ON/OFF

Power Switch/

Circuit Breaker

AC Outlets (4)

(connect equipment here)

Transformer

Block AC

Outlet

AC Plug

(to wall outlet)

Building Wiring

Fault Indicator

(see

Plug the

Line-R into Wall

Outle

t)

User Selectable Voltage Switch

(see

Select Input Voltage

)

Installation

• Placement -

Please install the Line-R in a protected environment free of excessive dust,

mechanical vibration, inflammable gases and explosive or corrosive atmospheres.

Do not block the top or side air vents on the unit. Allow 1 inch (2.5 cm) minimum vent

clearance.

• Select Input Voltage -

The Line-R provides a three-position User Selectable Voltage

Switch for adjusting the input voltage for the region where it is being used (example: Mexico

- 127V, United States - 120V, or Jamaica - 110V). Slide the switch to select the proper

voltage for your location.

• Plug the Line-R into Wall Outlet -

Plug the Line-R into a grounded AC wall outlet. If the

Building Wiring Fault Indicator is lit, the building wiring presents a potential shock hazard

and should be serviced by a qualified electrician before putting this device into service. The

Line-R should only be used in buildings having proper grounding, with conductors protected

by fuses or circuit breakers.

• Connect Your Equipment -

Plug equipment into the Line-R rear-panel outlets and switch

the equipment ON. The equipment will not be powered until the Line-R is switched ON.

CAUTION:

The total power consumption of all equipment plugged into the Line-R must not

exceed the ratings listed in the

Specifications

table below. A total load in excess of the listed

ratings will cause the ON/OFF power switch/circuit breaker to “trip”.

• Switch ON the Line-R

- Press the front panel ON/OFF power switch/circuit breaker to the

ON (

l

) position. This switch may be used as the master ON/OFF switch for the device and all

equipment connected to the unit.

Specifications

Characteristics

Model LE600

Model LE1200

Maximum Output Power

Capacity

600 W or 600 VA

1200 W or 1200 VA

Nominal Output Voltage

110, 120, or 127 (User Selectable)

Nominal Input Current

5 A

10 A

Input Voltage Range

80 - 130V (Selector Switch set to 110V)
85 - 140V (Selector Switch set to 120V)
90 - 150V (Selector Switch set to 127V)

Maximum Input Voltage

250V

Surge Energy

702 Joules

Output Regulation

+6 to -12%

Response Time

< 2 AC Cycles

Efficiency

>93%

Nominal Frequency

50/60 Hz

Number of Outlets

4

Operating Temperature

32 - 104°F (0 - 40°C)

Relative Humidity

0 - 95% Non-condensing

Dimensions

4.6 x 8.4 x 5.5 inches (118 x 214 x 141 mm)

Weight

7.25 lb (3.3 kg)

9.7 lb (4.4 kg)

2.5 cm

(1 inch)

Limited Warranty

American Power Conversion (APC) warrants its products to be free from defects in materials

and workmanship for a period of two years from the date of purchase. Its obligation under this

warranty is limited to repairing or replacing, at its sole option, any such defective products. To

obtain service under warranty you must obtain a Return Material Authorization (RMA)

number from APC or an APC service center. Products must be returned to APC or an APC

service center with transportation charges prepaid and must be accompanied by a brief

description of the problem encountered and proof of date and place of purchase. This warranty

does not apply to equipment which has been damaged by accident, negligence, or

misapplication or has been altered or modified in any way. This warranty applies to the

original purchaser who must have proper registered the product within 10 days of purchase.
EXCEPT AS PROVIDED HEREIN, AMERICAN POWER CONVERSION MAKES NO

WARRANTIES, EXPRESSED OR IMPLIED, INCLUDING WARRANTIES OF

MERCHANTIBILITY AND FITNESS FOR A PARTICULAR PURPOSE. Some countries

do not permit limitation or exclusion of implied warranties; therefore, the aforesaid

limitation(s) or exclusion(s) may not apply to the purchaser.
EXCEPT AS PROVIDED ABOVE, IN NO EVENT SHALL APC BE LIABLE FOR

DIRECT, INDIRECT, SPECIAL, INCIDENTAL, OR CONSEQUENTIAL DAMAGES

ARISING OUT OF THE USE OF THIS PRODUCT, EVEN IF ADVISED OF THE

POSSIBILITY OF SUCH DAMAGE. Specifically, APC is not liable for any costs, such as

lost profits or revenue, loss of equipment, loss of use of equipment, loss of software, loss of

data, costs of substitutes, claims by third parties, or otherwise. This warranty gives you

specific legal rights and you may also have other rights which may vary from location to

location.

Contact Information

990-1286

A

Copyright © 200

3

American Power Conversion All rights reserved.

Technical Support

http://www.apc.com/support

Internet

http://www.apc.com

North America

1.800.800.4APC

Mexico

292.0253 / 292.0255

Worldwide

+1.401.789.5735

APC and Line-R are registered trademarks of American Power Conversion.

All other trademarks are the property of their respective owners.

"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.

Other APC Models

All APC Other