APC HT1000 - Manual
APC HT1000 – Manual, read for free online in PDF format. We hope this helps you resolve any issues you may have. If you have further questions, please contact us through the contact form.
Data Port
BR24BP Battery Pack
User’s Manual
Back-UPS
®
HT1000
1
CONTENTS
2
3
CONNECT BATTERY CARTRIDGE
OPERATING ENVIRONMENT
3
4
CONNECT EQUIPMENT AND POWER
5
Building
Wiring Fault
Building Wiring
Fault Indicator
6a
Phone
Computer
Modem Port
CONNECT PHONE,
6b
CONNECT 10/100 Base-T
Network Jack
Computer
Network Port
8
To Computer USB
Port
CONNECT INTERFACE
Computer
There are four status indicators (lights) on the front
panel of the Back-UPS (On Line, On Battery,
Overload, and Replace Battery).
On Line (green)
- is lit whenever utility power is
powering the Battery Backup outlets.
On Battery (yellow)
- is lit whenever the battery of
the Back-UPS is powering equipment connected to
the Battery Backup Outlets.
Four Beeps Every 30 Seconds
- this alarm is
sounded whenever the Back-UPS is running
On Battery. Consider saving work-in-
progress.
Overload (red)
- is lit whenever power demand has
exceeded the capacity of the Back-UPS.
Continuous Tone
- this alarm is sounded
whenever the Battery Backup outlets are
overloaded.
Circuit Breaker
- the circuit breaker button
located on the rear panel of the Back-UPS will
stick out if an overload condition forces the
Back-UPS to disconnect itself from utility
power. If the button sticks out, disconnect non-
essential equipment. Reset the circuit breaker
by pushing the button inward.
Replace Battery (red)
- is lit whenever the
battery is near the end of its useful life, or if the
battery is not connected (see above). A battery
that is near the end of its useful life has
insufficient run-time and should be replaced.
Chirps for 1 Minute Every 5 Hours
-
this alarm is sounded whenever the
battery has failed the automatic
diagnostic test.
Note: Allow the Back-UPS to charge for a full eight
(8) hours prior to use.
Press the front panel Power ON/OFF switch and
observe that the following events occur after pressing
and releasing the switch:
• The green On Line indicator flashes.
• The yellow On Battery indicator lights while a
Self-Test is being performed.
• When Self-Test has successfully completed, only
the green On Line indicator will be lit.
• If the internal battery cartridge is not connected
(see Step 2 above), the green On Line indicator
and red Replace Battery indicators will light. The
Back-UPS will also emit a chirping sound.
Continuous Beeping
- this alarm is sounded
whenever a low battery condition is reached.
Battery run-time is very low. Promptly save
any work in progress and exit all open appli-
cations. Shutdown the operating system,
computer and the Back-UPS.
If the rear panel Building Wiring
Fault (red) indicator is lit, a potential
shock hazard exists due to one of the
following conditions:
• Open or high resistance ground
• Hot or neutral polarity reversed
• Overloaded neutral circuit
Improper building wiring should be
corrected by a qualified electrician.
Do not use the Back-UPS until the
condition that caused the fault is
corrected.
Note
: Improper building wiring will
not prevent the Back-UPS from
operating, but it will limit its
protection capability.
9
SWITCH ON THE BACK-UPS
On Line
On Battery
Overload
Replace Battery
w
w
w.apc.com
®
RJ-45
USB
STATUS INDICATORS AND ALARMS
For connection of APC’s optional
external 24-volt battery pack
(BR24BP) to the Back-UPS HT 1500.
CABLE
32 - 104
o
F (0 - 40
o
C)
Wall
Outlet
10/100 Base-T/VOIP
Modem/Phone/Fax
Jack
From Cable Provider
(Phone, Internet,
and/or CATV, or
DSS)
To Cable Modem,
VCR, DSS or TV
Cable Box
or VOIP
MODEM, FAX
CABLE IN
CABLE OUT
7
OR
✔
✔
✔
✔
✔
®
RJ-45
USB
RJ-11
RJ-11
✔
✔
✔
RJ-45
RJ-45
Coaxial Cable
User’s Manual
Software CD-ROM
Pedestal
Back-UPS HT
Plasma/
DVR or
CD / DVD Drive
Media PC
High Definition TV
Wall
Outlet
10/100 Base-T/VOIP
Modem/Phone/Fax
10
INSTALL SOFTWARE ON
COMPUTER
If Autoplay is enabled on your computer, the
software on the CD-ROM will automatically start
the installation program.
If Autoplay is not enabled on the computer, proceed
as follows:
1. On the computer desktop of the display, double-
click on My Computer.
2. Double-click on the CD-ROM drive icon and
follow the on-screen instructions.
Follow the
on-screen
instructions.
11
FINAL
ORIENTATION
✘
✔
✔
CONNECT COAXIAL CABLES
(PHONE, INTERNET, and/or
CATV or DSS)
CHECK BUILDING
WIRING FAULT
INDICATOR
To AC Utility
Power
Input: 120V~
12A, 60Hz
Circuit Breaker
Push to Reset
SURGEONLY
BATTERY BACKUP
Input: 120V~
12A, 60Hz
Circuit Breaker
Push to Reset
HT 1500 Rear Panel
HT 1000 Rear Panel
Note:
All outlets on the HT1500 provide
battery backup and surge protection.
and HT 1500
"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.