Page 2 - AMX Limited Warranty and Disclaimer; Warranty Repair Policy
AMX Limited Warranty and Disclaimer All products returned to AMX require a Return Material Authorization (RMA) number. The RMA number is obtained from the AMX RMA Department. The RMA number must be clearly marked on the outside of each box. The RMA is valid for a 30-day period. After the 30-day peri...
Page 3 - Table of Contents
Table of Contents i AXB-TC and AXB-TCR Television Controllers (& Receivers) Table of Contents AXB-TC and AXB-TCR Television Controllers ..................................................... 1 Overview ..................................................................................................
Page 5 - AXB-TC and AXB-TCR Television Controllers; Overview
AXB-TC and AXB-TCR Television Controllers 1 AXB-TC and AXB-TCR Television Controllers (& Receivers) AXB-TC and AXB-TCR Television Controllers Overview The AXB-TC and AXB-TCR Television Controllers are intelligent, microprocessor-controlled systems equipped with a lithium battery to protect store...
Page 6 - Specifications
AXB-TC and AXB-TCR Television Controllers 2 AXB-TC and AXB-TCR Television Controllers (& Receivers) Specifications The following table list the product specifications for the television controllers. Other than the IR Input Window (on the AXB-TCR only), the specifications for the TC and TCR are i...
Page 7 - Applications; FIG. 2 shows a sample system configuration.
AXB-TC and AXB-TCR Television Controllers 3 AXB-TC and AXB-TCR Television Controllers (& Receivers) Applications FIG. 2 shows a sample system configuration. AXB-TC/TCR Specifications (Cont.) Mounting options: Flat surface Included accessories: • CC-IR TV Sensor (CC-XPS sensor)• CC-IRC IR Emitter...
Page 9 - Installation and Wiring; Setting the Device DIP Switch; Jumper JP1; sets the input mode for power sensing or power current sensing.; Jumper JP2; sets the IR output mode for IR or serial communication.; Jumper JP3; sets the IR attenuation mode for bypass or adjustment.
Installation and Wiring 5 AXB-TC and AXB-TCR Television Controllers (& Receivers) Installation and Wiring Setting the Device DIP Switch The eight-position Device DIP switch sets the identification number for the television controller. Make sure the device number matches the number assigned in th...
Page 10 - JI jumper settings: TV power sensing/TV power current sensing mode; JI Jumper Settings: TV Power Sensing/TV Power Current Sensing; J2 Jumper Settings: IR Output Mode (IR or Serial Communication)
Installation and Wiring 6 AXB-TC and AXB-TCR Television Controllers (& Receivers) JI jumper settings: TV power sensing/TV power current sensing mode J2 jumper settings: IR output mode (IR or serial communication) J3 jumper settings: IR attenuation mode (bypass or adjustment) JI Jumper Settings: ...
Page 11 - Wiring guidelines; Strip 0.25 inch of wire insulation off all wires.; TV Sensor connections
Installation and Wiring 7 AXB-TC and AXB-TCR Television Controllers (& Receivers) Wiring The TV sensor, IR emitter, AXlink, and 12 VDC power supply connectors are located on the rear panel of the television controller as shown in FIG. 1 on page 1. Wiring guidelines The television controller requ...
Page 12 - IR Emitter connections
Installation and Wiring 8 AXB-TC and AXB-TCR Television Controllers (& Receivers) IR Emitter connections Connect the CC-IRC IR Emitter to the IR Emitter connector, on the rear panel of the television controller (FIG. 3) to transmit IR control signals to the television. Axlink data and power conn...
Page 13 - PCS and Axlink data and power connections
Installation and Wiring 9 AXB-TC and AXB-TCR Television Controllers (& Receivers) PCS and Axlink data and power connections Connect the PCS Power Current Sensor to the TV Sensor connector, on the rear panel of the television controller (FIG. 6) to detect and control the television power status (...
Page 14 - Installation
Installation and Wiring 10 AXB-TC and AXB-TCR Television Controllers (& Receivers) Installation Install the television controller on any flat surface or inside the optional SE-TC Security Enclosure, as described below: 1. Mount the Axcess Central Controller where it will be used. Then, connect t...
Page 15 - Television Power Sensor Adjustment; Turn the television off.; IR Signal Attenuation Adjustment; Refer to
Installation and Wiring 11 AXB-TC and AXB-TCR Television Controllers (& Receivers) Television Power Sensor Adjustment After connecting the CC-IR to the television, the power sensing POT, on the rear of the television controller (see FIG. 1 on page 1), may require adjustment to detect the televis...
Page 16 - Replacing the Lithium Battery
Installation and Wiring 12 AXB-TC and AXB-TCR Television Controllers (& Receivers) 4. Turn the POT screw clockwise one-eighth turn to increase signal saturation. Then, send an IR control signal to the television. If the television performs correctly, go to step 5. If not, repeat this step until ...
Page 19 - Programming Information; Axcess Programming Guide; Channel Setting Commands
Programming Information 15 AXB-TC and AXB-TCR Television Controllers (& Receivers) Programming Information Overview The television controllers are controlled with channel settings, IR functions, and Axcess Send_Commands. You create software programs with the AMX Axcess programming software. Use ...
Page 20 - The following table lists the IR function, in their standard order.
Programming Information 16 AXB-TC and AXB-TCR Television Controllers (& Receivers) IR Functions (Standard Order) The following table lists the IR function, in their standard order. IR Functions (Standard Order) Functio n Description Functio n Description 1 play > 22 channel up or + 2 stop [] ...
Page 21 - Refer to the
Programming Information 17 AXB-TC and AXB-TCR Television Controllers (& Receivers) Send_Commands Use the Send_Commands listed in the following table to program the Axcess Central Controller and television controller. The device number range for the television controller is 1 through 255. Refer t...
Page 25 - Firmware Upgrades; Using SOFTROM; Press F5 to acquire the list of online programmable devices.
Programming Information 21 AXB-TC and AXB-TCR Television Controllers (& Receivers) Firmware Upgrades Firmware upgrades allow you to install the latest available operating system for your AXB-TC or AXB-TCR. The firmware reload is required anytime the unit's LEDs all flash at the same rate as the ...
Page 26 - Using NetLinx Studio
Programming Information 22 AXB-TC and AXB-TCR Television Controllers (& Receivers) 7. Upon completion of the upgrade, press F10 to exit SOFTROM. Firmware can be downloaded to multiple device numbers automatically. If multiple devices are selected, the bottom half of the loading bar will indicate...
Page 27 - Yes; Once it has rebooted, click; OK
Programming Information 23 AXB-TC and AXB-TCR Television Controllers (& Receivers) 9. Once the .TSK file has been downloaded, the program prompts you to reboot the Axcess Master. Click Yes to reboot, and the program initiates the reboot sequence. When the Master has rebooted, the Status LED on t...