American Standard M968641 - Manual
American Standard M968641 – Manual, read for free online in PDF format. We hope this helps you resolve any issues you may have. If you have further questions, please contact us through the contact form.
Table of Contents:
- Page 3 – Important: If SUPPLY HOSES
- Page 4 – CAUTION
- Page 5 – Speed ConnectTM Drain; Troubleshooting Guide; CABLE ADJUSTMENT PROCEDURE; If Stopper does not raise up fully or sink drains too slowly:; STOPPER REMOVAL PROCEDURE
- Page 6 – STOPPER INSTALLATION PROCEDURE; rear; “Locked”; front; “Unlocked”; Unlocked Mode
6
4
COLLAR ON
MOUNTING NUT
7
5
Figure B
M 9 6 8 6 4 1
Certified to comply with ANSI A112.18.1
Installation
Instr uctions
M O N O B L O C K L AVAT O R Y F A U C E T w i t h
Speed Connect™ Drain
Adjustable Wrench
Screwdriver
Channel Locks
Recommended tools
Tubing Cutter
1
INSTALL FAUCET
Turn off hot and cold water
supplies before beginning.
CAUTION
7430.101
1
BERWICK
™
1
2
5
4
GROOVE
(FAUCET
BASE)
MOUNTING
SURFACE
3
8
Seat SEAL
(1)
into under side of ESCUTCHEON RING
(2)
.
Feed FAUCET SUPPLIES
(3)
, MOUNTING STUD
(4)
and DRAIN
CABLE ASSEMBLY
(8)
through ESCUTCHEON RING
(2)
and the
mounting hole of lavatory or mounting surface.
Figure A.
Seat ESCUTCHEON RING
(2)
with collar facing up into groove in
faucet base.
From below, push GASKET
(7)
and RETAINING WASHER
(5)
onto
MOUNTING STUD
(4)
. Secure Faucet with MOUNTING NUT
(6)
,
pulling faucet to front of sink, so SUPPLIES
(3)
rests against
mounting hole. Before final tightening, make sure collar on
MOUNTING NUT
(6)
is seated into RETAINING WASHER
(5)
.
Figure B.
Adjust Faucet so that it is centered. Tighten MOUNTING NUT
(6)
to complete faucet mounting.
Figure A
To ensure that your installation proceeds smoothly-please read these instructions carefully before you begin.
Congratulations on purchasing your American Standard
faucet with Speed Connect drain, a feature found only on
American Standard faucets.
*Your new American Standard faucet is designed to work only with the Speed Connect drain.
Speed Connect Drain*
• Fewer parts, installs in less time
• Never needs adjustment
• Guaranteed to seal properly the first time, every time.
"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.
Summary
M 9 6 8 6 4 1 Operate LIFT KNOB (1) to verify that STOPPER (2) opens and closes. Note: If STOPPER (2) does not open and close properly then refer to the “troubleshooting section” of these instructions. CHECK OPERATION OF POP-UP 8 2 MAKE WATER SUPPLY AND WASTE CONNECTIONS 9 Thread CABLE CONNECTOR (1)...
1 2 4 5 6 2.5mm HEX KEY REMOVE INSTALL 7 8 M 9 6 8 6 4 1 1 4 10 TEST INSTALLED FITTING With HANDLE (1) in OFF position, turn on WATER SUPPLIES (2) and check all connections for leaks. Remove AERATOR (3) . Operate HANDLE (1) to flush water lines thoroughly. Replace AERATOR (3) . 3 CHECK DRAIN CONNECT...
M 9 6 8 6 4 1 Speed Connect™ Drain Troubleshooting Guide Disconnect the Cable from the Drain by threading the Cable Connector (1) counter-clockwise. Fig. A. Look at the area on the Drain Body where the Cable was attached and locate the component labeled as “Cam” and “Cam Cap” in the illustration. Fi...