American Standard M968498 - Manual

American Standard M968498

American Standard M968498 – Manual, read for free online in PDF format. We hope this helps you resolve any issues you may have. If you have further questions, please contact us through the contact form.

1 Page 1
2 Page 2
3 Page 3
4 Page 4
5 Page 5
6 Page 6
7 Page 7
8 Page 8
9 Page 9
10 Page 10
11 Page 11
12 Page 12
Page: / 12

Table of Contents:

  • Page 2 – How to order the Selectronic Product; In; Specifications; Roughing-in Dimensions; INSTALL SPOUT ASSEMBLY; INSTALLATION; CAUTION; Figure 2; For installations on drywall or tiled walls; CONNECT SPOUT HOSE TO; Key for vandal resistant aerator; UNPACKING
  • Page 7 – RED
  • Page 9 – Note: Keep water flowing out of faucet while shutting off.; Note: It is recommended to clean strainer every 6; supplied with faucet.; Rinse Clean with water. Reassemble and install into; spout end. Be sure black seal washer is in place.; HOW TO CLEAN AND REMOVE; I N N S B R O O K w i t h; L AVAT O R Y FA U C E T S; PRODUCT NUMBERS
Loading the manual

(In Toronto Area only: 1-905-3061093)

Innsbrook Lavatory Faucet

with SELECTRONIC™ Technology

To learn more about American Standard Faucets visit our website at:

www.us.amstd.com

or U.S.

customer's e-mail us at:

[email protected]

For Parts, Service, Warranty or other Assistance,
please call

1-800-442-1902 (In Canada: 1-800-387-0369)

NOTE TO INSTALLER: Please give this manual to the customer after installation.

(In Toronto Area only: 1-905-3061093)

1

605XTMV

6055.202

6055.205

PRODUCT No.s

6056.202

6056.205

6057.202

6057.205

1

8

3

2

7

4

Mixing Valve

B
a
s
e

P
r
o
d
u
c
t

How to order the Selectronic Product

1. Choose Power Supply

2. Choose Desired Spout

• Single Hole Sink

• Single Inlet

• 1 and 3 Hole Sinks

• Hot and Cold Inlets

Base Product

Mixing Valve (optional)

In

s

ta

ll

a

ti

o

n

I

n

s

tr

u

c

ti

o

n

s

© 2005 American Standard

Product No.'s & Options

Specifications

How to Install

Electrical Hook-up

Maintenance

FAQ,s

Replacement Parts

1

2

2-3

4-6

7-8

9

10

M968498 Rev.1.2

Certified to comply with ASME A112.18.1M

TOOLS REQUIRED; Fig. 2

Fig. 2

Fig. 1

1

Channel Locks

2

Adjustable Wrench

3

Plumbers' Putty or Caulking

4

Phillips Screwdriver

5

Flat Blade Screwdriver

6

Electric Drill & 1/4" Drill Bit

7

Tape Measure

1

2

3

4

5

6

7

MOUNTING

SURFACE

Roughing-in Dimensions

10'

GENERAL DESCRIPTION:

Electronic faucet with proximity operation. Vandal resistant

solid brass construction 4" center to center mounting.

Operates on DC (battery) or AC permanent power. In-line

strainer for solenoid is integral. Single inlet 3/8 compression,

built-in checks, and flexible stainless steel 15" reach inlet

hose for spout connection.

INSTALL SPOUT ASSEMBLY;

Fig. 3

INSTALLATION

CAUTION

Turn off hot and cold water

supplies before beginning

1.

Make sure PUTTY PLATE

(1)

is installed on

FAUCET BODY

(2)

.

Fig. 1a.

2.

Insert WIRES

(3)

, FLEX HOSE

(4)

and STUDS

(5)

through holes of mounting surface.

Fig. 1a.

3.

From under side of mounting surface install SPIN

NUTS

(6)

onto MOUNTING STUDS

(5)

.

Fig. 1b.

4.

Align FAUCET

(2)

and hand tighten SPIN NUTS

(6)

to secure faucet to mounting surface.

Fig. 1b.

Fig. 1a

1

2

114mm

(4-1/2)

508mm

(20)

1524mm

(60)

381mm

(15)

3/8" COMP.

125mm

(4-7/8)

81mm

(3-3/16)

175mm

(6-7/8)

162mm

(6-3/8)

155mm

(6-1/8)

102mm

(4)

35mm

(1-3/8)

DIA.

3 HOLES

38mm

(1-1/2)

MAX.

124mm

(4-7/8)

108mm

(4-1/4)

57mm

(2-1/4)

1

6

5

2
4

3

6

5

5

Fig. 1b

Fig. 2

1.

Determine location of ENCLOSURE

(1)

. It must be

located with-in the 14" (356mm) by 21" (533mm)
shaded area shown in

Figure 2

in order for electrical

connections from the spout assembly to be made.

NOTE: ENCLOSURE SUPPLY HOSE is 20". Distance
between wall supply and ENCLOSURE (1) must be
taken into consideration.

2.

Remove 4 screws from COVER

(2)

and pull off

COVER

(2)

. Hold the ENCLOSURE

(1)

in desired

location and mark the four mounting hole locations as
shown.

Fig. 2.

3.

The ENCLOSURE

(1)

works best if secured to a wall

stud or cross brace within the wall, using the SCREWS

(3)

supplied. If the ENCLOSURE

(1)

is to be installed on

a tile or plaster wall the ANCHORS

(4)

and SCREWS

(3)

should be used.

4.

For installations on drywall or tiled walls;

use

ANCHORS

(4)

and SCREWS

(3)

for securing

ENCLOSURE

(1)

to finished wall. Drill four 1/4" dia.

holes a minimum of 1-3/4" deep. Insert the four
ANCHORS

(4)

flush with face of the finished wall.

Align the ENCLOSURE

(1)

and Install the MOUNTING

SCREWS

(3)

. Tighten to secure ENCLOSURE

(1)

to

mounting surface.

1524mm

(60)

14"

(356mm)

3-3/4"

(96mm)

2-3/4"

(71mm)

3"

(76mm)

21"

(mm)

2

4

3

1

1

1

20"

(500mm)

MOUNTING HOLES

SUPPLIES

WASTE

ENCLOSURE

MOUNTING

HOLES

LAVATORY RIM OR

MOUNTING SURFACE

3

NOTE: If using Mixing Valve (optional) See Sheet
#M968808 for installation instructions.

MOUNT ENCLOSURE; Fig. 2

2

1.

Connect SUPPLY NUT

(1)

from spout assembly to

nipple on top of ENCLOSURE

(2)

. Tighten with

adjustable wrench to make a water tight connection.

Fig. 3.

NOTE; If using the optional Mixing Valve See Sheet
#M968808 for installation instructions.

CONNECT SPOUT HOSE TO

ENCLOSURE; Fig. 3

CONNECT WATER SUPPLY TO

ENCLOSURE AND WALL SUPPLY;

Fig. 4

3

Fig. 3

4

1

2

1

3

3

Fig. 4

2

1.

Insert FIBER WASHER

(4)

into SUPPLY NUT

(1)

on

ENCLOSURE

(2)

.

2.

Connect SUPPLY NUT

(1)

on ENCLOSURE

(2)

to

FLEXIBLE SUPPLY HOSE

(3)

. Tighten to make a

water tight connection. Use two wrenches to tighten if
necessary.

Fig. 4.

3.

Connect FLEXIBLE SUPPLY

(3)

directly to wall

supply. Connection on FLEXIBLE SUPPLY

(3)

is 3/8"

compression. Use adjustable wrench to tighten

connection. Do not over tighten.

Fig. 4a.

Note:

FLEXIBLE SUPPLY

(3)

measures 20" from the

bottom of the ENCLOSURE

(1)

base. If additional

supply length is required, installer must purchase parts

separately.

Important:

If FLEXIBLE SUPPLY

(3)

is too long, loop to

avoid kinking.

COLD WATER OR

TEMPERED

WALL SUPPLY

Fig. 4a

4

5b. AC Power Supply (for 6056 series)
5c. 10 ft. Extension Wire (for 6057 series)
6. Circuit board
7. Mixing Valve (

optional must be ordered separately

)

8. Key for vandal resistant aerator

1. Selectronic Spout Assembly
2. Mounting Kit
3. Electrical Enclosure
4. Supply Hose
5a. DC Power Supply (for 6055 series)

All American Standard Faucets Are Water Tested At Our Factory.
Some Residual Water May Remain In The Faucet During Shipping.

Thank you for selecting American-Standard...the benchmark of fine quality for over 100 years. To
ensure that your installation proceeds smoothly--please read these instructions carefully before you
begin.

UNPACKING

1. Remove the fitting and loose items from the carton. The illustration below shows the fitting and all loose items

after they have been removed from the carton. Some items may be packaged partially assembled to other items.

5a

5b

6

5c

"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.

Summary

Page 2 - How to order the Selectronic Product; In; Specifications; Roughing-in Dimensions; INSTALL SPOUT ASSEMBLY; INSTALLATION; CAUTION; Figure 2; For installations on drywall or tiled walls; CONNECT SPOUT HOSE TO; Key for vandal resistant aerator; UNPACKING

(In Toronto Area only: 1-905-3061093) Innsbrook Lavatory Faucet with SELECTRONIC™ Technology To learn more about American Standard Faucets visit our website at: www.us.amstd.com or U.S. customer's e-mail us at: [email protected] For Parts, Service, Warranty or other Assistance, please call 1-8...

Page 7 - RED

'03"$7&34*0/ .6-5*)00,61'JH 6OJU 6OJU 6OJU 4FF"$7FSTJPO&MFDUSJDBM)PPLVQGPSGJSTUVOJUPG UIF.VMUJIPPLVQ 3FNPWF&/$-0463&$07&34GSPNBMM &/$-0463&4 3FNPWF40-*%#-"$,*/4&35 GSPNSJHIUTJEF PG&/$-0463&BOESFQMBDFXJUIHSBZ1*&$& (30..&5 3FQMBDFTPMJECMB...

Page 9 - Note: Keep water flowing out of faucet while shutting off.; Note: It is recommended to clean strainer every 6; supplied with faucet.; Rinse Clean with water. Reassemble and install into; spout end. Be sure black seal washer is in place.; HOW TO CLEAN AND REMOVE; I N N S B R O O K w i t h; L AVAT O R Y FA U C E T S; PRODUCT NUMBERS

FAQ'S Q: How will I know if battery needs to be replaced?A: Valve does not open and sensor blinks 2 times interrupted by pause for up to 7 days. Q: Why has the flow rate of the faucet reduced significantly?A: Check and clean aerator and strainer. Q: There is no flow out of faucet when I'm in the sen...

Other American Standard Models

All American Standard Other