American Standard 2305.100 - Manual

American Standard 2305.100

American Standard 2305.100 – Manual, read for free online in PDF format. We hope this helps you resolve any issues you may have. If you have further questions, please contact us through the contact form.

1 Page 1
Page: / 1
Loading the manual

© 2003 American Standard Inc.

CI-6

MADERA™16-1/8” HEIGHT

ELONGATED FLUSH VALVE TOILET

VITREOUS CHINA

MADERA™ 16-1/8” HEIGHT 10” ROUGH TOILET

• Vitreous china

• Low-consumption (6.0 Lpf/1.6 gpf)

• Elongated bowl

• Fully glazed 2” ballpass trapway

• 10” x 12” water surface area

• Direct-fed siphon jet action

• 10” Rough-in

• 1-1/2" inlet spud

• 2 bolt caps

• 100% factory flush tested

2305.100 Top spud

2305.156 Top spud with slotted rim for

bedpan holding

Compliance Certifications -
Meets or Exceeds the Following Specifications:
• ASME A112.19.2M (and 19.6M) for Vitreous

China Fixtures - includes Flush Performance,
Ball Pass Diameter, Trap Seal Depth and
all Dimensions

Nominal Dimensions: 778 x 381 x 409mm
(30-1/2" x 15" x 16-1/8")

Fixture only, seat and flush valve by others.

Recommended working pressure--between
25 psi at valve when flushing and 80 psi static

To Be Specified

Color:

White

Bone

Silver

Shell

Black

Seat: Olsonite #95 open front seat less cover

Seat: Church #9500C open front seat less cover

Flush Valve: Sloan Royal #111 or equal

1 - 1/2
SPUD

121mm

(4-3/4)

702mm

(27-5/8)

235mm

(9-1/4)

410mm

(16-1/8)

470mm

(18-1/2)

394mm

(15-1/2)

356mm

(14)

127mm

(5

254mm

(10)

13mm
(1/2)

3 8 m m
( 1 - 1 / 2 )

1 0 2 m m
( 4 )

7 7 5 m m

( 3 0 - 1 / 2 )

C/L OF SEAT POST HOLES
( 5 - 1/2 CENTERS)

FINISHED WALL

FINISHED FLOOR

C/L OF OUTLET

1" N.P.T. OR 1" C.W.T. SUPPLY
TO FLUSH VALVE

When installed so top of seat is 432 to 483mm (17" to 19") from the

finished floor.

MEETS THE AMERICAN DISABILITIES ACT GUIDELINES AND ANSI A117.1
REQUIREMENTS FOR ACCESSIBLE AND USEABLE BUILDING FACILITIES-
CHECK LOCAL CODES.

NOTES:
TO COMPLY WITH AREA CODE GOVERNING THE HEIGHT OF VACUUM BREAKER ON THE
FLUSH VALVE, THE PLUMBER MUST VERIFY DIMENSIONS SHOWN FOR SUPPLY ROUGH-
ING.
THIS TOILET DESIGNED TO ROUGH-IN AT A MINIMUM DIMENSION OF 254MM (10”) FROM
FINISHED WALL TO C/L OF OUTLET.
FLUSH VALVE NOT INCLUDED WITH FIXTURE AND MUST BE ORDERED SEPARATELY.
IMPORTANT: Dimensions of fixtures are nominal and may vary within the range of tolerance
established by ANSI Standard A112.19.2
These measurements are subject to change or cancellation. No responsibility is assumed for use
of superseded or voided pages.

Revised 5/03

BARRIER FREE

"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.