  • Page 3 – SpeedDome; Installation Guide–Continuation; To the Installer; Tamperproof; Purchase or Supply Separately; Male BNC connector; Tools Required; Torx bit
  • Page 4 – Warnings and Cautions; Warnings; North America power requirements:; Cautions; Lightning Protection Reference
  • Page 5 – Preventing Condensation; Exploded view
  • Page 6 – Connector Pin Assignments; Manchester; Cable Requirements; Data Cable; Data cable requirements; Power Cable
  • Page 7 – Leave the dome camera set; Unterminating the Outdoor Housing; TB5 Pin Designations
  • Page 8 – Keep the cover and use it to protect
  • Page 9 – Troubleshooting; Dome Does Not Respond to Commands; Connector P7 pin outs
  • Page 10 – SensorNet Data Connections; Blowers Do Not Turn
  • Page 11 – Ice Forms On Bubble; Specifications; Environmental
  • Page 12 – Declarations; Regulatory Compliance; Other Declarations
Loading the manual

-

IMPORTANT!

This housing meets IP66/Nema 4 ratings

provided it is used with a properly installed ROENDC End
Cap Assembly and one of the following mounts: RHOTR
Over-the-Roof Mount, RHOSW Short Wall Mount, or
RHOLW Long Wall Mount.

ADSDUHOC, ADSDUHOS, ADSDUHOVRC, ADSDUHOVRS

SpeedDome

®

Ultra Outdoor Housing Installation Guide

Before performing these steps, read additional
information attached for important details and
warnings!

At end of pipe.

Ensure black foam plug is around
cable and press-fit into pipe.

Ensure seal and sleeve are
properly set.

See A, B, C.

Line up.

Push to line and

maintain

compression.

Tighten.

Thread cables through end
cap assembly and attach
housing to mounting
structure.

Keep cables from
twisting while turning
housing.

Turn until no threads
are exposed.

Attach cable
connectors.

Make connections,
insert cables into end
cap assembly, and
attach cover.

Check o-ring is
properly set.

Page 1 of 12 8200-0492-02, Rev. C

Seal

Sleeve

1

B

A

2

A

3

B

C

= Step Prevents

Water Intrusion.

Green 3-Pin Connector (Power)

Pin 1 - Black (24Vac)
Pin 2 - Red (Common)
Pin 3 - White (24Vac)

Green 2-Pin Connector (Twisted Pair Video)

Pin 1 - + (video high)
Pin 2 - – (video ground)

Gray 5-Pin Connector
(Relay)

Pin 1 - Blue (NC)*
Pin 2 - Purple (Common)*
Pin 3 - Gray (NO)*
Pin 4 - White/Red (Alarm Return)
Pin 5 - White/Black (Alarm 1)
* Relay contact not to exceed 1A @

30Vdc or 0.3A @ 125Vac.

Black Connector (Data)

Manchester

Pin 1-4 - Not used
Pin 5 - White/Orange (Manchester W)
Pin 6 - White/Yellow (Manchester B)

RS-422

Pin 1 – Orange (Rx +)
Pin 2 – Green (Rx –)
Pin 3 – Yellow (Tx +)
Pin 4 – Brown (Tx –)
Pins 5-6 - Not used

SensorNet

Pin 1-4 - Not used
Pin 5 - White/Orange (SensorNet Hi)
Pin 6 - White/Yellow (SensorNet Lo)

Blue 4-Pin Connector
(Alarm)

Pin 1 - White/Blue (Alarm 2)
Pin 2 - White/Brown (Alarm 3)
Pin 3 - White/Purple (Alarm 4)
Pin 4 - White/Red (Alarm Return)

"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.

Summary

Page 3 - SpeedDome; Installation Guide–Continuation; To the Installer; Tamperproof; Purchase or Supply Separately; Male BNC connector; Tools Required; Torx bit

SPEEDDOME ULTRA OUTDOOR HOUSING 8200-0492-02, REV. C INSTALLATION GUIDE - CONTINUATION 3 of 12 SpeedDome ® Ultra Outdoor Housing Installation Guide–Continuation ADSDUHOC ADSDUHOS ADSDUHOVRC ADSDUHOVRS Contents: To the Installer....................................................... 3 About the Produ...

Page 4 - Warnings and Cautions; Warnings; North America power requirements:; Cautions; Lightning Protection Reference

SPEEDDOME ULTRA OUTDOOR HOUSING 8200-0492-02, REV. C INSTALLATION GUIDE - CONTINUATION 4 of 12 Warnings and Cautions Please review the following warnings and cautions before you begin installation or service. Warnings WARNING! Always use proper lift and safety equipment for the location and type of ...

Page 5 - Preventing Condensation; Exploded view

SPEEDDOME ULTRA OUTDOOR HOUSING 8200-0492-02, REV. C INSTALLATION GUIDE - CONTINUATION 5 of 12 Preventing Condensation Damage, missing parts, or procedures that most often allow water to enter the housing are as follows (refer to figures opposite): † Missing O-ring on cover, or missing sleeve or sea...

Other American Dynamics Models

All American Dynamics Other