Aiphone LEF-3L - Manual

Aiphone LEF-3L

Aiphone LEF-3L – Manual, read for free online in PDF format. We hope this helps you resolve any issues you may have. If you have further questions, please contact us through the contact form.

1 Page 1
2 Page 2
3 Page 3
4 Page 4
5 Page 5
6 Page 6
7 Page 7
8 Page 8
9 Page 9
10 Page 10
11 Page 11
12 Page 12
Page: / 12

Table of Contents:

  • Page 2 – Wire Reference Chart (North America only); Offi ces; VOICE
  • Page 3 – SYSTEM OUTLINE & COMPONENTS; System outline; White; Package contents
  • Page 4 – Precautions on Installation & Wiring
  • Page 5 – To access the inside of the unit for making wire connections:; Carefully lift front of intercom up and off the back chassis.; PUSH; Directory card
  • Page 7 – MOUNTING; Back wiring; Surface wiring
  • Page 8 – WIRING DIAGRAMS - Most Common Applications; WIth Selective Door Release; Optional Remote station:
  • Page 9 – WIRING DIAGRAMS - Multiple Masters for Door Answering; One door station with the ability to activate a separate doorbell; Shown with external signaling and door release relays; POWER
  • Page 10 – OPERATIONS & SPECIFICATIONS; Calling a master or sub:
  • Page 11 – RESTRICTIONS; TROUBLESHOOTING GUIDE; POSSIBLE CAUSE; Wire
  • Page 12 – WARRANTY
Loading the manual

– 1 –

- SUPPLEMENT TO LEF INSTRUCTIONS -

The LEF-3L is a compact, wall or desk mount master station able to selectively release a door or call up a camera.

Used with any LE-(except LEF-3,5 and 10) or LS-series (North America only) remote station, communication can be

established with each station by selecting the channel on the master station. While the channel is selected, pressing

the door release button (left of TALK button) will release only the associated door. When used for camera call-up, a relay

closure will be maintained as long as a station is selected. The system can have up to four stations, in any combination of

masters or door stations (e.g. 2 masters and 2 doors). Master-to-master communication is also a standard feature.

(If communication between masters is not required, multiple LEF-3L's can be used to talk to 3 door stations.)

PRECAUTIONS

WARNING

(Negligence could result in death or serious injury.)

1. Do not dismantle or alter the unit. Fire or electric shock could result.
2. Do not connect any non-specifi ed power source to the +, - terminals, and do not install two power supplies in

parallel to a single input. Fire, damage to the unit, or system malfunction could result.

3. Keep the unit away from water or any other liquid. Fire or electric shock could result.
4. When existing chime wires are used, it is possible that they contain AC voltage. Electric shock or unit damage

could result. Ask a qualifi ed technician.

5. Do not use DC power supply with a voltage other than specifi ed. Fire or electric shock could result

.

CAUTION

(Negligence could result in injury or damage to property.)

1. Before turning on the power, make sure wires are not crossed or shorted. Fire or electric shock could result.
2. When mounting the unit on wall, install the unit in a convenient location, but not where it could be jarred or

bumped. Injury could result.

3. For DC powered systems, use Aiphone power supply model specifi ed with system. If non-specifi ed product is

used, fi re or malfunction could result.

4. Do not install or make any wire terminations while power supply is plugged in. It can cause electrical shock or

damage to the unit.

5. In case of electrical storms, unplug the unit from AC outlet. If not, fi re or electric shock could result.
6. Do not install the unit in any of the following locations. Fire, electric shock, or unit trouble could result.

* Places under direct sunlight, or near heating equipment that varies in temperature.

* Places subject to dust, oil, chemicals, hydrogen sulfi de (hot spring).

* Places subject to moisture and humidity extremes, such as bathroom, cellar, greenhouse, etc.

* Places where the temperature is quite low, such as inside a refrigerated area or in front of air-conditioner.

* Places subject to steam or smoke (near heating or cooking surfaces).

* Where noise generating devices such as dimmer switches, invertor electrical appliances, are closeby.

7. Do not install the unit in a location subject to constant vibration or impact. If dropped, injury or unit damage

could result.

GENERAL PRECAUTIONS

1. Keep the unit more than 1 m (3.3') away from Radio or TV set.
2. In areas where broadcasting station antennas are close by, the intercom system may be affected by radio

frequency interference.

3. The unit will be inoperative during a power outage.
4. This unit is for indoor use only. Do not use outdoors.

LEF-3L

3-Call Master Station with Selective Control Capability (Door Release or Camera Call-up)

Used with LE-D, LE-DA, LE-DL, LS-NVP/C Door Stations

P0015311

A

0109Y

General Prohibitions

Prohibition on Subjecting the Unit to Water

Prohibition to Dismantle the Unit

General Precautions

aiphone̲e.indd   1

09.2.17, 2:13:51 PM

"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.

Summary

Page 2 - Wire Reference Chart (North America only); Offi ces; VOICE

– 2 – Wire Reference Chart (North America only) Standard Communication With selective door release and/ or camera call-up Model # # of Conductors Wire # (22AWG) Wire # (18AWG) # of Conductors Wire # (22AWG) LEF-3L 9 822210 x 12 822212 LE-A 3 822203 821803 x x LE-D 3 822203 821803 x x LE-DA 3 822203 ...

Page 3 - SYSTEM OUTLINE & COMPONENTS; System outline; White; Package contents

– 3 – 2  SYSTEM OUTLINE & COMPONENTS ■   System outline Individual Components for LEF-3L System: * : North America only *LS-NVP/C    Vandal and weather resistant sub station, white powder coated (optional SBX-NVP surface box) *LE-SS     Stainless Steel 2-Gang sub station *LE-SSR     Stainless St...

Page 4 - Precautions on Installation & Wiring

– 4 – 2  SYSTEM OUTLINE & COMPONENTS (Cont.) LE-D/LE-DA TERMINAL DEFINITIONS: 1   Station number E   Common communication −   Negative *LS-NVP/C TERMINAL DEFINITIONS: Red   Station number Black   Common communication Green   Negative *LE-SS(R)/LE-SS-1G COLOR CODE: Red    Station number Black    ...

Other Aiphone Models

All Aiphone Other