1 Page 1
2 Page 2
3 Page 3
4 Page 4
5 Page 5
6 Page 6
7 Page 7
8 Page 8
Page: / 8

Table of Contents:

  • Page 3 – station. One SA-1 is required for every two wires connected to; WIRING DIAGRAMS
  • Page 4 – c. THREE MASTER STATIONS WITH SUBS WIRED TO DIFFERENT MASTERS
  • Page 5 – e. SINGLE MASTER SYSTEM WITH ALL CALL; is wired to a standard sub station.
  • Page 6 – Shielded cable is recommended.; OPERATIONS & SPECIFICATIONS; Receiving a call from a sub station:; ss; Calling a sub or master station:; ss; Receiving a call from another master station:; ss
  • Page 7 – TROUBLESHOOTING GUIDE; PROBLEM; No call tone or LED when sub calls master.; SOLUTION
  • Page 8 – PRECAUTIONS & WARRANTY; CAUTION; Toll Free Technical Support; WARRANTY
Loading the manual

- INSTRUCTIONS -

The LAF-C Console Master system is a loudspeaker type, single talkpath open voice system. Multiple masters
can be used, along with a large variety of sub station models to create a communication system tailored to the
user's needs. Master stations are available in 20-and 40-station sizes, with or without a handset. For greater
capacity, include a 20- or 40-station add-on selector. Any "LE-" or "LS-" series sub station can be used.
All Call and/or Background Music are optional features requiring additional equipment (BG-10C, PS-12F).

LAF-C LAF-CA

LAF-C Console Master Loudspeaker Intercom System

LAF-20C

LAF-40C

LAF-20CA

LAF-40CA

Special
Order
Products

Pg. 1

1

NAMES & FEATURES

FEATURES:

· Single or multi-master capability
· Commercial grade, durable master station for heavier usage
· Master stations available with our without a handset
· Single talkpath, with push-to-talk operation or handset at master, and hands free communication
at sub station
· Large variety of sub stations available

- Surface or flush mount, with or without privacy (LE-A, LE-AN, LE-B, LE-BN)
- Weather resistant door stations (LE-D, LE-DA, LE-DL)
- Vandal proof sub station (LS-NVP, LS-NVP-W (weatherized), SBX-DGV surface mt. box)

· Selective calling to sub stations, and master-to-master communication
· Subs call in with momentary tone and LED, remaining lit for approximately 20 seconds
· Optional All Call (additional equipment required) to call all stations simultaneously
· Equipment used for All Call also allows for background music to be heard through master and subs
· Master is desk or wall mountable, and LAF-20CA can be rack mounted with RMK-01 rack mount kit
· 20- and 40-call add-on selectors available, with LA-40AS rack mountable with RMK-02.

NAMES & FUNCTIONS:

1. Handset
2. Power indicator
3. Microphone
4. Speaker
5. Terminal Block
6. OFF button
7. Selector button
8. Power switch
9. Voice volume control
10. Call tone volume control
11. All Call button
12. TALK button
13. Occupied LED
14. OFF LED
15. Directory card
16. Station selector LED

LAF-20CA (pictured)

Type E

92101 1198

"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.

Summary

Page 3 - station. One SA-1 is required for every two wires connected to; WIRING DIAGRAMS

3a. SINGLE MASTER SYSTEM, NO ALL CALL 12345 ~ 20 EEEE - CR Y P1P2P3 + - LAF-20C + - PS-12C LE-A 1 E - LE-A LE-D Pg. 3 3b. DUAL MASTER SYSTEM WITH MASTER-TO-MASTER COMMUNICATION 1 E - 1 E - LE-D 1 E - NOTES:Two wiring method can be used: 1. 2 conductor homerun to each sub station from the master. (Si...

Page 4 - c. THREE MASTER STATIONS WITH SUBS WIRED TO DIFFERENT MASTERS

3 WIRING DIAGRAMS 3c. THREE MASTER STATIONS WITH SUBS WIRED TO DIFFERENT MASTERS + - PS-12C LS-NVP Red Blk Grn LAF-40CA 123 ~ 37 E - C 3940 R Y P1P2P3 + - LAF-40CA 123 ~ 37 E - 38 C 40 R Y P1P2P3 + - 123 ~ 37 E - 3839 CR Y P1P2P3 + - LAF-40CA NOTE: When wiring LS-NVPsubs with two wires,black and gre...

Page 5 - e. SINGLE MASTER SYSTEM WITH ALL CALL; is wired to a standard sub station.

Pg. 5 3 WIRING DIAGRAMS + - PS-12F 3e. SINGLE MASTER SYSTEM WITH ALL CALL 1 2 3 ~ 10 11 12 ~ 20 C E - + R Y P1 P2 P3 LAF-20CA LE-BN 1 E - LE-BN LE-BN 1 E - 1 E - LE-BN 1 E - BG-10C #1 BG-10C #2 1 2 ~ 10 E - + R Y P1 P2 P3 + - R E L E NP-25V NP-25V + - PS-12F LE-BN 1 E - LE-BN 1 E - DC IN NOTES: 1. A...

Other Aiphone Models