Page 2 - Copyright; nd Edition
MIC-3043 User Manual ii Copyright The documentation and the software included with this product are copy-righted 2006 by Advantech Co., Ltd. All rights are reserved. Advantech Co., Ltd. reserves the right to make improvements in the products described in this manual at any time without notice. No pa...
Page 4 - FCC Class A
MIC-3043 User Manual iv Declaration of ConformityCE This product has passed the CE test for environmental specifications when shielded cables are used for external wiring. We recommend the use of shielded cables. This kind of cable is available from Advantech. Please contact your local supplier for ...
Page 5 - Technical Support and Assistance; Step 1. If you have any technical questions about the MIC-3043 or any; Document Feedback
v Technical Support and Assistance Step 1. If you have any technical questions about the MIC-3043 or any other Advantech products, please visit our support website at: www.advantech.com.tw/support Step 2. Contact your distributor, sales representative, or Advantech's cus- tomer service center for te...
Page 6 - Safety Instructions
MIC-3043 User Manual vi Safety Instructions 1. Read these safety instructions carefully. 2. Keep this User's Manual for later reference. 3. Disconnect this equipment from any AC outlet before cleaning. Use a damp cloth. Do not use liquid or spray detergents for clean- ing. 4. For plug-in equipment, ...
Page 7 - Wichtige Sicherheishinweise
vii 16. CAUTION: DANGER OF EXPLOSION IF BATTERY IS INCORRECTLY REPLACED. REPLACE ONLY WITH THE SAME OR EQUIVALENT TYPE RECOMMENDED BY THE MANUFACTURER, DISCARD USED BATTERIES ACCORD- ING TO THE MANUFACTURER'S INSTRUCTIONS. The sound pressure level at the operator's position according to IEC 704-1:19...
Page 8 - Safety Precaution - Static Electricity
MIC-3043 User Manual viii zu trennen und von einer qualifizierten Servicestelle zu überprüfen: a - Netzkabel oder Netzstecker sind beschädigt.b - Flüssigkeit ist in das Gerät eingedrungen.c - Das Gerät war Feuchtigkeit ausgesetzt.d - Wenn das Gerät nicht der Bedienungsanleitung entsprechend funk- ti...
Page 9 - Contents; Chapter
ix Table of Contents Contents Chapter 1 Hardware Configuration ................................ 2 1.1 Introduction ....................................................................... 2 1.2 Features ............................................................................. 3 1.3 Specifications...
Page 11 - Hardware Configuration
Page 12 - Chapter 1 Hardware Configuration
MIC-3043 User Manual 2 Chapter 1 Hardware Configuration 1.1 Introduction The MIC-3043 is a 4U-high enclosure designed as a high availability platform that supplies six CompactPCI slots for rack mounting. At the same height as a typical 4U platform, the MIC-3043 offers the equivalent capacity of 6U s...
Page 13 - power supplies; Construction; : Aluminum frame and galvanized sheet steel
3 Chapter 1 • MIC-3043D : A 4U-high CompactPCI enclosure with 6-slot backplane with CT bus support, removable/ hot-swappable SATA device bay, hot-swappable cooling fan modules. Power supply not included. • MIC-3043D-B : identical to MIC-3043D chassis including 1+1 (250W+250W) redundant AC cPCI power...
Page 15 - Dimensions and Appearance
5 Chapter 1 1.4 Dimensions and Appearance Figure 1.1: MIC-3043 functional block diagram Figure 1.2: Appearance of MIC-3043
Page 17 - Installation
Page 18 - Chapter 2 Installation; Initial Inspection
MIC-3043 User Manual 8 Chapter 2 Installation 2.1 Initial Inspection We have carefully inspected the MIC-3043 mechanically and electrically before shipping. It should be free of marks and scratches and in perfect working order upon receipt. As you unpack the MIC-3043, check it for signs of shipping ...
Page 19 - Installation Procedures; To install a card
9 Chapter 2 Figure 2.2: Front view of MIC-3043 2.3 Installation Procedures 2.3.1 Card Installation and Removal The CompactPCI connectors are firm and rigid, and require careful han-dling. Improper installation of a card can easily damage the backplane of the chassis.The system card can be installed ...
Page 21 - To remove a card; Slide the HDD with mobile rack back into the tray.
11 Chapter 2 To remove a card : 1. Unscrew the screws on the card front panel. Release the locking latches on the handles. 2. Lift the upper handle up and press the lower handle down to release the card from the backplane. 3. Slide the card out. 2.3.2 Before Operating the System Before operating you...
Page 23 - Seagate
13 Chapter 2 2.3.6 Configuring the built-in IDE for the RIO module (MIC-3043A and IC-3043B series) The MIC-3043A and MIC-3043B have IDE versions that support a removable HDD (not hot-swappable). Since there are many different HDD connectors on the market, please refer to the combination list "HD...
Page 24 - Figure 2.6: The location of jumper switch
MIC-3043 User Manual 14 Figure 2.5:IDE adaptor (type B 2.3.7 Configuring the built-in SATA for the RIO module (MIC-3043D series) MIC-3043D has SATA versions that support a removable or hot-swappa-ble HDD which depends on RIO module type. Hot-swappable mode must use RIO module supporting SATA interfa...
Page 25 - Unfasten the fan holder.
15 Chapter 2 2.3.8 Replacing the Hot-swap Fan The MIC-3043 provides one hot-swap fan. Please refer to Figure 2-1 and 2-2. The fan can be removed without turning off the system power or interrupting the system operation.Follow these steps to replace a fan:1. Unfasten the fan holder. 2. Slide the fan ...
Page 27 - Backplane
Page 28 - Chapter 3 Backplane; General Information; pactPCI power supplies
MIC-3043 User Manual 18 Chapter 3 Backplane 3.1 General Information There are two backplanes models that are compatible with the MIC-3043 series. MIC-3043A, MIC-3043C and MIC-3043D support the H.110 CT bus backplane, the MIC-3811. The MIC-3043B supports a non-CT back-plane MIC-3812. Both backplanes ...
Page 29 - • Complies with CompactPCI Front-Access Power Connectors PICMG; Slot Assignments
19 Chapter 3 • Complies with CompactPCI Front-Access Power Connectors PICMG 2.11, R3.0. • Complies with CompactPCI Computer Telephony PICMG2.5, R1.0 (optional) • Dimensions: 440 x 177 x 320 mm (17.3" x 7" x 12.6")• Operating temperature: 0° C ~ 45° C 3.4 Slot Assignments The CompactPCI s...
Page 30 - Table 3.1: System to peripheral slot signal assignment
MIC-3043 User Manual 20 Table 3.1: System to peripheral slot signal assignment System Slot (Logical Slot 5) Peripheral Slot (Logical Slot 6) CLK4 P1:D6 CLK P1:D6 AD31 P1:E6 IDSEL P1:B9 REQ0# P1:A6 REQ# P1:A6 GNT0# P1:E5 GNT# P1:E5 System Slot (Logical Slot 5) Peripheral Slot (Logical Slot 4) CLK1 P2...
Page 31 - Connector and Jumper Locations; Table 3.2: Backplane connector and jumper description
21 Chapter 3 Figure 3.1: MIC-3811 and MIC-3812 slot numbering 3.5 Connector and Jumper Locations The backplane provides connectors and jumpers for users to configure the backplane for specific applications. Table 3-2 gives a brief description of each connector on the backplane. Figures 3-3 to 3-6 il...
Page 33 - These connectors accept the separate AC/DC power input.
23 Chapter 3 3.5.1 AC/DC Power Connector (CN3, CN17) These connectors accept the separate AC/DC power input. 3.5.2 Power Switch This connector provides power control over the plug-in power module. If the CompactPCI chassis provides a 2-pin power switch cord, connect this cord to the CN15 connector t...
Page 34 - Figure 3.6: Location of alert indicators; Clock Routing Configuration; The fan4 is reserved as factory default.
MIC-3043 User Manual 24 3.5.4 Fan Module Connector The FAN connectors provide +12 V power for fan operation and relay the tachometer output from the fans. 3.5.5 Alert indicators The MIC-3043 series alarm module (MIC-3924L-A) provides two alert signals to the chassis front panel, close to the HDD bay...
Page 35 - APPENDIX; Pin Assignments
Page 36 - Appendix A Pin Assignments; Pin
MIC-3043 User Manual 26 Appendix A Pin Assignments A.1 MIC-3812 and MIC-3811 System Slot P1 Connector #: Low activity Table A.1: MIC-3812 and MIC-3811 system slot P1 connector Pin Z A B C D E F 25 GND +5V REQ64# ENUM# +3.3V +5V GND 24 GND AD[1] +5V V(I/O) AD[0] ACK64# GND 23 GND +3.3V AD[4] AD[3] +5...
Page 44 - A.9 MIC-3812 Peripheral Slot P4 Connector
MIC-3043 User Manual 34 A.9 MIC-3812 Peripheral Slot P4 Connector #: Low activity Table A.9: MIC-3812 Peripheral System Slot P4 Connector Pin Z A B C D E F 25 GND NC NC NC NC NC GND 24 GND NC NC NC NC NC GND 23 GND NC NC NC NC NC GND 22 GND NC NC NC NC NC GND 21 GND NC NC NC NC NC GND 20 GND NC NC N...
Page 55 - Ordering Information
Page 56 - Appendix B Ordering Information; : A 4U-high CompactPCI enclosure with removable IDE
MIC-3043 User Manual 46 Appendix B Ordering Information • MIC-3043A : A 4U-high CompactPCI enclosure with removable IDE device bay, hot swappable cooling fan modules, and a 6-slot backplane that provides H.110 CT bus support (MIC-3811). Power supply is not inlcuded. • MIC-3043A-B : A 4U-high Compact...
Page 57 - Default Alarm Module; • MIC-3924L-A: Chassis management module without remote control; Upgradeable Alarm Module; • MIC-3924A-B: Chassis management module with remote control for
47 Appendix B For the recommended 6U CompactPCI SBC, please refer to the table below: Default Alarm Module : • MIC-3924L-A: Chassis management module without remote control for general purpose chassis and single SBC applications. Upgradeable Alarm Module • MIC-3924A-B: Chassis management module with...