Page 2 - Copyright; Acknowledgements
EKI-2525M & 2526M User Manual-V2.1-051507 ii Copyright The documentation and the software included with this product are copyrighted 2007 by Advantech Co., Ltd. All rights are reserved. Advantech Co., Ltd. reserves the right to make improvements in the products described in this manual at any ti...
Page 4 - Declaration of Conformity
EKI-2525M & 2526M User Manual-V2.1-051507 iv Declaration of Conformity CE This product has passed the CE test for environmental specifications. Test conditions for passing included the equipment being operated within an industrial enclosure. In order to protect the product from being damaged by ...
Page 5 - Safety Instructions
v Safety Instructions 1. Read these safety instructions carefully. 2. Keep this User's Manual for later reference. 3. Disconnect this equipment from any AC outlet before cleaning. Use a damp cloth. Do not use liquid or spray detergents for cleaning. 4. For plug-in equipment, the power outlet socket ...
Page 6 - Safety Precaution - Static Electricity
EKI-2525M & 2526M User Manual-V2.1-051507 vi Safety Precaution - Static Electricity Follow these simple precautions to protect yourself from harm and the products from damage. 1. To avoid electrical shock, always disconnect the power from your PC chassis before you work on it. Don't touch any co...
Page 7 - Contents
vii Contents Contents Chapter 1 Overview ........................................... 2 1.1 Introduction ........................................................ 2 1.1.1 High-Speed Transmissions ....................... 2 1.1.2 Dual Power Input ...................................... 2 1.1.3 Flexible M...
Page 9 - Overview; Introduction
1 Chapter1 Overview Sections include: Introduction Features Specifications Packing List Safety Precaution C H A P TE R
Page 10 - Chapter 1 Overview
EKI-2525M & 2526M User Manual-V2.1-051507 2 Chapter 1 Overview 1.1 Introduction The EKI-2525M/2526M is a cost-effective solution and meets the high reliability requirements demanded by industrial applications. 1.1.1 High-Speed Transmissions The EKI-2525M/2526M is an industrial switch which provi...
Page 13 - Certifications
5 Chapter1 -10~60 Operating Humidity 5%~95% (non-condensing) Storage Temperature -40~85 Certifications Safety UL, 60950-1, CAN/CSA-C22.2 No.60950 EMC U.S.A.: FCC Part 15 CISPR 22 EU: EN55011, EN61000-6-4 EN55022, Class A, EN61000-3-2/3 EN55024 IEC61000-4-2/3/4/5/6/8/11/12 EN61000-6-2 Free Fall IEC60...
Page 14 - Safety Precaution
EKI-2525M & 2526M User Manual-V2.1-051507 6 1.4 Packing List • 1 x EKI-2525M or 1 x EKI-2526M Industrial Ethernet Switch • 1 x eAutomation Industrial Communication CD-ROM with software, and User manual • 2 x Wall Mounting Bracket and Screws • 1 x DIN-rail Mounting Bracket and Screws • 1 x EKI-25...
Page 15 - Installation; LED Indicators
7 Chapter2 Installation Sections include: LED Indicators Dimensions Mounting Network Connection Power Connection C H A P TE R
Page 16 - Chapter 2 Installation
EKI-2525M & 2526M User Manual-V2.1-051507 8 Chapter 2 Installation In this chapter, you will be given an overview of the EKI-2525M/2526M hardware installation procedures. 2.1 LED Indicators There are few LEDs display the power status and network status located on the front panel of EKI-2525M/252...
Page 21 - Wall mounting
13 Chapter2 2.3 Mounting The EKI-2525M/2526M supports two mounting methods: DIN-rail & Wall. 2.3.1 Wall mounting EKI-2525M/2526M can be wall-mounted by using the included mounting kit. Then, hang on the EKI-2525M/2526M to the nails on the wall. First, use the screws included in the package to co...
Page 24 - Network Connection
EKI-2525M & 2526M User Manual-V2.1-051507 16 2.4 Network Connection The EKI-2525M or EKI-2526M has the SC type fiber port in multi mode (2Km). When you connect the fiber port to another one, please follow the below figure to connect it. Wrong connection will not allow the port to work normally. ...
Page 25 - Power Connection
17 Chapter2 2.5 Power Connection The EKI-2525M/2526M supports dual +12 ~ 48 V DC power inputs and power-fail relay output. Figure 2.9: Pin Assignment of the Power Connector You can connect an alarm indicator, buzzer or other signaling equipment through the relay output. The relay opens if power inpu...
Page 27 - Troubleshooting
Page 28 - Chapter 3 Troubleshooting
EKI-2525M & 2526M User Manual-V2.1-051507 20 Chapter 3 Troubleshooting 1. Power Input Verify that is using the right power cord/adapter (+12~48 V DC ), please don’t use the power adaptor with DC output voltage higher than 48V, or it will burn this converter down. 2. Cable Select the proper UTP c...
Page 29 - Pin Assignment & Wiring; IX
21 Chapter2 Pin Assignment & Wiring A P P E N D IX
Page 30 - Appendix A Pin Assignment & Wiring
EKI-2525M & 2526M User Manual-V2.1-051507 22 Appendix A Pin Assignment & Wiring It is suggested to adopt ELA/TIA as the wiring of the RJ-45. Figure A.1: RJ-45 Pin Assignment Figure A.2: EIA/TIA-568B Figure A.2: EIA/TIA-568A