ADTRAN QFO-C - Manual
ADTRAN QFO-C – Manual, read for free online in PDF format. We hope this helps you resolve any issues you may have. If you have further questions, please contact us through the contact form.
Table of Contents:
- Page 2 – C A U T I O N !; Table 2. QFO-only Populated Total Access Chassis; Warranty and Customer Service; Compliance Codes; Table 1. Compliance Codes; Wiring
- Page 4 – N O T E
- Page 5 – Figure 2. Total Access 3000 CO Chassis
- Page 6 – Figure 3. Fiber Optic Receiver Cabling; Fiber Optic Transceiver
- Page 9 – Figure 4
- Page 11 – Laser degrade signal
- Page 12 – Entering the Fiber Main Menu Screen; Figure 5. Fiber Main Menu Screen
- Page 13 – Accessing the QFO-C Provisioning Screen
- Page 14 – Figure 10. Provisioning of All Ports Screen; Port 0 is the QFO-C access module itself.; Changing the Port Service State; Figure 9. Port Service Status Screen
- Page 15 – Figure 11. DSX Equalization Screen
- Page 17 – Restore Factory Default Settings
- Page 18 – Figure 18. Status of All Ports Screen; Viewing the Status of a Single Port; Figure 17. Port Status Screen
- Page 19 – Figure 20. Alarm Reporting Screen; Accessing the Alarms Screen; Figure 19. Alarms Screen
- Page 20 – Changing Alarm Settings and Thresholds; number of desired setting and press Enter.; Figure 21. Alarm Provisioning Screen; Alarm Provisioning
- Page 21 – Type number of desired setting and press Enter.
- Page 22 – number of the desired setting and press Enter.
- Page 23 – Figure 28. Test Screen; Setting Up Loopbacks for a Test
- Page 24 – Figure 29. Port Test Screen; Loopback RT: Disabled; Figure 30. Loopback RT Screen; Performing Loopback Testing; displays the Loopback
- Page 25 – Figure 32. Performance Monitoring Screen; shows the Loopback DSX Screen. Type; Loopback DSX: Disabled; Figure 31. Loopback DSX Screen
- Page 26 – Figure 34. Protection Switch Screen; Viewing Performance Monitoring Screens; Figure 33. Port Performance Monitoring Screen
- Page 27 – Figure 36. Circuit ID Screen; Setting the Port Circuit ID; Figure 35. Protection Switch Activate Screen
- Page 28 – WARRANTY AND CUSTOMER SERVICE; document; ADTRAN Sales; Figure 37. Port Current Circuit ID Screen
- Page 29 – ANSI X3T9.5 Fiber Distributed Data Interface
61181300L1-5C
Section 61181300L1-5C, Issue 3
1
Section 61181300L1-5C
Issue 3, October 2000
CLEI Code # M3O1CD0C_ _
Total Access
TM
QFO-C
Installation and Maintenance
1. GENERAL
This practice is an installation and maintenance guide
for the ADTRAN Total Access QFO-C, P/N
1181300L1, illustrated in
Figure 1
. See Table 5 for a
description of QFO-C front panel indicators.
Revision History
This is the third issue of this practice. This issue includes
the removal of the four-character display (FCD)
five-minute time out feature.
Features
The Total Access QFO-C carries up to four
asynchronous DS1 circuits over a single-mode fiber
pair with an optical budget of 22 dB (minimum). The
Total Access QFO-C has the following features:
CONTENTS
1. GENERAL ............................................................................ 1
2. INSTALLATION .................................................................. 2
3. OPERATION ........................................................................ 5
4. MAINTENANCE ................................................................ 28
5. WARRANTY AND CUSTOMER SERVICE ................... 28
FIGURES
Figure 1.
Total Access QFO-C .............................................. 1
Figure 2.
Total Access 3000 CO Mounting Shelf ................. 5
Figure 3.
Fiber Optic Receiver Cabling ................................. 6
Figure 4.
QFO-C FCD Menu Tree ....................................... 10
Figure 5.
Fiber Main Menu Screen ...................................... 12
Figure 6.
QFO-C Configuration Screen ............................... 12
Figure 7.
Provisioning Screen .............................................. 13
Figure 8.
Service State Screen ............................................. 13
Figure 9.
Port Service Status Screen .................................... 14
Figure 10.
Provisioning of All Ports Screen .......................... 14
Figure 11.
DSX Equalization Screen ..................................... 15
Figure 12.
Loopback Timeout Screen .................................... 15
Figure 13.
AIS to DSX (Loss of T1) Screen ......................... 16
Figure 14.
AIS to DSX (FLOS) Screen ................................. 16
Figure 15.
Restore Factory Defaults Screen .......................... 17
Figure 16.
Status Screen ......................................................... 17
Figure 17.
Port Status Screen ................................................. 18
Figure 18.
Status of All Ports Screen ..................................... 18
Figure 19.
Alarms Screen ....................................................... 19
Figure 20.
Alarm Reporting Screen ....................................... 19
Figure 21.
Alarm Provisioning Screen .................................. 20
Figure 22.
ES Threshold (15-Minutes) Screen ...................... 20
Figure 23.
SES Threshold (15-Minutes) Screen .................... 21
Figure 24.
UAS Threshold (15-Minutes) Screen .................. 21
Figure 25.
ES Threshold (24-Hours) Screen ......................... 22
Figure 26.
SES Threshold (24-Hours) Screen ....................... 22
Figure 27.
UAS Threshold (24-Hours) Screen ...................... 23
Figure 28.
Test Screen ............................................................ 23
Figure 29.
Port Test Screen .................................................... 24
Figure 30.
Loopback RT Screen ............................................ 24
Figure 31.
Loopback DSX Screen ......................................... 25
Figure 32.
Performance Monitoring Screen .......................... 25
Figure 33.
Port Performance Monitoring Screen .................. 26
Figure 34.
Protection Switch Screen ..................................... 26
Figure 35.
Protection Switch Activate Screen ....................... 27
Figure 36.
Circuit ID Screen .................................................. 27
Figure 37.
Port Current Circuit ID Screen ............................. 28
TABLES
T
able 1.
Compliance Codes .................................................. 2
Table 2.
QFO-only Populated Total Access Chassis ........... 2
Table 3.
Pin-out for Pair 5 and 7 on TA 3000 ...................... 3
Table 4.
Pin-out for Pair 6 and 8 on TA 3000 ...................... 3
Table 5.
Pin-out for Pair 5 and 7 on TA 3010 ...................... 4
Table 6.
Pin-out for Pair 6 and 8 on TA 3010 ...................... 4
Table 7.
QFO-C Front Panel Indicators ............................... 7
Trademarks: Any brand names and product names included in this document are
trademarks, registered trademarks, or trade names of their respective holders.
Figure 1. Total Access QFO-C
QF0-C
DSX
PWR
DSX
DSX
TST
ALM
ACT
A
P
S
GRN = NORM
YEL = MAN
1181300L1
DSX
#2
#3
#4
#1
Table 8.
QFO-C Provisioning Options ................................. 8
Table 9.
QFO-C Menu Hierarchy ....................................... 11
Table 10.
QFO-C Specifications .......................................... 29
"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.
Summary
2 Section 61181300L1-5C, Issue 3 61181300L1-5C • Installs in both the Total Access 3000 (23-inch) and the Total Access (19-inch) chassis. • End-to-end transmission for one to four DS1 circuits • Operating wavelength 1310 nm • Single mode fiber operation • Power budget of 25dB (typical) • Launch powe...
4 Section 61181300L1-5C, Issue 3 61181300L1-5C If the system is configured with only QFO-Cs, all fourDSX-1 connections are made. The connections aremade via four Amphenol connectors to Pair 5 throughPair 8 on the backplane. Table 5. Pin-out For Pair 5 and 7 on TA 3010 r o l o C p u o r G r e d n i B...
61181300L1-5C Section 61181300L1-5C, Issue 3 5 If no protection switching is provided, the Main unitplugs into any odd-numbered slot. The next highereven-numbered slot may contain a blank card or canbe left empty. See Figure 2 . Installing the QFO-C 1. Set the right switch segment S2-2 to Working “o...