Page 3 - Table of Contents
Quick Installation Guide Contents Version 5.0 3 September 2007 Table of Contents 1 Introduction ................................................................................................................. 7 2 Quick Start .............................................................................
Page 5 - © Copyright 2007 AudioCodes Ltd. All rights reserved.
Quick Installation Guide Notices Version 5.0 5 September 2007 Notices Notice This Quick Installation Guide describes the installation and configuration of AudioCodes’ Media Pack MP-11x FXO SIP analog media gateways for integration with Microsoft ® Office Communications Server 2007. Information conta...
Page 6 - Related Documentation; Manual Name; FXO; receive
MP-11x & Microsoft Office Communications Server 2007 Quick Installation Guide 6 Document #: LTRT-26301 Related Documentation Document # Manual Name LTRT-656xx (e.g., LTRT-65601 MP-11x & MP-124 SIP Release Notes LTRT-654xx MP-11x & MP-124 SIP User's Manual Warning: Ensure that you connect...
Page 7 - Introduction; Figure
Quick Installation Guide 1. Introduction Version 5.0 7 September 2007 1 Introduction This guide provides step-by-step instructions for quickly setting up AudioCodes' MediaPack (MP-118 and MP-114) Session Initiation Protocol (SIP) voice-over-IP (VoIP) gateways for intermediating between third-party, ...
Page 9 - Quick
Quick Installation Guide 2. Quick Start Version 5.0 9 September 2007 2 Quick Start This Quick Installation Guide helps you setup the MediaPack gateways for interoperability with either third-party PBXs or various PSTN interfaces, and Office Communications Server 2007. Prior knowledge of IP networks ...
Page 10 - Configuring; Embedded Web Server Management Tool; the; To access the Embedded Web Server, take these 4 steps:; OK
MP-11x & Microsoft Office Communications Server 2007 Quick Installation Guide 10 Document #: LTRT-26301 3 Configuring the MediaPack The gateway is supplied with the application software residing on its flash memory (set to factory default parameters). Note: This guide assumes that the gateway is...
Page 11 - Navigating the Embedded Web Server
Quick Installation Guide 3. Configuring the MediaPack Version 5.0 11 September 2007 3.1.2 Navigating the Embedded Web Server The main areas of the Web interface are shown in the figure below. Figure 3-2: MediaPack Web Interface Areas
Page 12 - Changing Login Username and Password; To change the user name and password, take these 3 steps:
MP-11x & Microsoft Office Communications Server 2007 Quick Installation Guide 12 Document #: LTRT-26301 3.1.3 Changing Login Username and Password It's recommended that you change the default user name and password of the Web user account initially used to access the Embedded Web Server. ¾ To ch...
Page 13 - for; ini file Parameters; Search
Quick Installation Guide 3. Configuring the MediaPack Version 5.0 13 September 2007 3.1.4 Searching for ini file Parameters The Embedded Web Server provides a search engine that allows you to search any ini file parameter that is configurable using the Embedded Web Server. The search result provides...
Page 14 - Assigning an IP Address to the MediaPack; an; To assign an IP address using BootP, take these 3 steps:
MP-11x & Microsoft Office Communications Server 2007 Quick Installation Guide 14 Document #: LTRT-26301 3.2 Assigning an IP Address to the MediaPack If the gateway's default IP address (refer to Table 3-1 ) doesn't correspond to the network in which Office Communications Server 2007 is installed...
Page 15 - Assigning an IP Address Using CLI via RS-232; To assign an IP address using CLI via RS-232, take these 5 steps:; conf; GCP IP; SCP IP
Quick Installation Guide 3. Configuring the MediaPack Version 5.0 15 September 2007 Table 3-2: Adding a BootP Client 3. Use the gateway's chassis reset button to physically reset the gateway, causing it to use BootP; the gateway changes its network parameters to the values provided by BootP. 3.2.2 A...
Page 16 - Assigning an IP Address using HTTP; To assign an IP address to the gateway using HTTP, take these 5 steps:; Quick Setup
MP-11x & Microsoft Office Communications Server 2007 Quick Installation Guide 16 Document #: LTRT-26301 3.2.3 Assigning an IP Address using HTTP You can assign an IP address to the gateway using the gateway's Embedded Web Server (based on HTTP), by connecting the gateway to a PC with a direct, l...
Page 17 - Reset; Configuration; ini File; ini File from the Web
Quick Installation Guide 3. Configuring the MediaPack Version 5.0 17 September 2007 3. Configure the gateway's ‘IP Address’, ‘Subnet Mask’, and ‘Default Gateway IP Address’ fields to correspond with your network IP settings of Office Communications Server 2007. 4. Click the Reset button, and then at...
Page 18 - To download the ini file to your PC, take these 4 steps:; ini File to the Gateway; To upload the ini file to the gateway, take these 6 steps:
MP-11x & Microsoft Office Communications Server 2007 Quick Installation Guide 18 Document #: LTRT-26301 Notes: • Ensure that you download the correct ini file so that your gateway is configured correctly for interoperability with the deployed PBX / PSTN. • The gateway configuration for the PBX-S...
Page 19 - Parameters
Quick Installation Guide 3. Configuring the MediaPack Version 5.0 19 September 2007 Figure 3-8: Configuration File Screen 4. Click the Browse button, and then navigate to the folder that contains the ini file you want to upload. 5. Select the file, and then click the Open button; the name and path o...
Page 20 - Mediation Server's IP Address
MP-11x & Microsoft Office Communications Server 2007 Quick Installation Guide 20 Document #: LTRT-26301 3.3.2 Using the Embedded Web Server You can use the gateway's user-friendly, Web interface (described in Section 3.1 on page 10 ) to configure the advanced parameters listed below: IP addres...
Page 21 - To define Mediation Server's IP address, take these 4 steps:
Quick Installation Guide 3. Configuring the MediaPack Version 5.0 21 September 2007 ¾ To define Mediation Server's IP address, take these 4 steps: 1. Open the ‘Proxy & Registration' screen ( Protocol Management menu > Protocol Definition > Proxy & Registration ). Figure 3-9: Proxy &...
Page 22 - Protocol Management; Submit
MP-11x & Microsoft Office Communications Server 2007 Quick Installation Guide 22 Document #: LTRT-26301 3.3.2.2 Defining Number of FXO Ports Connected to PBX The gateway's FXO port (located on the rear panel), interfaces with the PBX. By default, all the gateway's FXO ports (eight for the MP-118...
Page 23 - To define the coder, take these 3 steps:; PBX/PSTN Connectivity
Quick Installation Guide 3. Configuring the MediaPack Version 5.0 23 September 2007 3.3.2.3 Defining Voice Coders The gateway communicates with Mediation Server using either the G.711 A-law or G.711 µ -law coder. You can change the default coder using the gateway's Embedded Web Server. ¾ To define t...
Page 24 - To configure the Number Manipulation tables, take these 4 steps:
MP-11x & Microsoft Office Communications Server 2007 Quick Installation Guide 24 Document #: LTRT-26301 ¾ To configure the Number Manipulation tables, take these 4 steps: 1. Open the Number Manipulation screen you want to configure ( Protocol Management menu > Manipulation Tables ); the relev...
Page 28 - To define the Answer Supervision, take these 3 steps:
MP-11x & Microsoft Office Communications Server 2007 Quick Installation Guide 28 Document #: LTRT-26301 3.3.2.5 Defining Answer Supervision When there is a call from Office Communications Server 2007 to the gateway, the gateway behavior depends on whether or not the Answer Supervision feature is...
Page 29 - Automatic
Quick Installation Guide 3. Configuring the MediaPack Version 5.0 29 September 2007 3.3.2.6 Defining Automatic Dialing When using the One-to-One option, each PBX line that is connected to an FXO port serves one OCS client. You must define automatic dialing for each FXO port connected to the OCS clie...
Page 30 - To enable Caller ID, take these 3 steps:
MP-11x & Microsoft Office Communications Server 2007 Quick Installation Guide 30 Document #: LTRT-26301 3.3.2.7 Enabling Caller ID If the Caller ID service is enabled, the gateway detects the Caller ID signal from the Tel side (PBX / PSTN) and sends it to Mediation Server over IP in the SIP INVI...
Page 31 - To define the SIP transport type, take these 3 steps:
Quick Installation Guide 3. Configuring the MediaPack Version 5.0 31 September 2007 3.3.2.8 Defining SIP Transport Type The procedure below describes how to configure the SIP transport type. You may need to change the gateway's SIP transport type from UDP (default) to TCP, since this is the transpor...
Page 32 - Disconnect on Broken Connection
MP-11x & Microsoft Office Communications Server 2007 Quick Installation Guide 32 Document #: LTRT-26301 3.3.2.9 Defining Disconnect on Broken Connection The procedure below describes how to configure the Disconnect on Broken Connection parameter. Since Mediation Server uses Silence Suppression, ...
Page 33 - To define the DTMF payload type, take these 3 steps:
Quick Installation Guide 3. Configuring the MediaPack Version 5.0 33 September 2007 3.3.2.10 Defining DTMF Payload Type The procedure below describes how to define the dual-tone multi-frequency (DTMF) payload type. The DTMF payload type used by Mediation Server is 101. You may need to set this value...
Page 35 - To define the Channel Select mode, take these 3 steps:
Quick Installation Guide 3. Configuring the MediaPack Version 5.0 35 September 2007 3.3.2.12 Defining Channel Select Mode Channel select modes determine the method in which new IP-to-Tel calls (i.e., calls from OCS clients to PBX/PSTN phones) are assigned to gateway ports (i.e., channels). It is rec...
Page 36 - To disable the RTCP attribute, take these 5 steps:; ini Parameters; Apply New Value
MP-11x & Microsoft Office Communications Server 2007 Quick Installation Guide 36 Document #: LTRT-26301 3.3.2.13 Disabling RTCP Attribute By default, the RTP Control Protocol (RTCP) attribute (EnableRTCPAttribute) is enabled. However, you need to disable it by using the AdminPage of the Embedded...
Page 37 - Backing Up Configuration Settings; To save the ini file on your PC, take these 6 steps:
Quick Installation Guide 4. Backing Up Configuration Settings Version 5.0 37 September 2007 4 Backing Up Configuration Settings Once you have modified configuration settings, it is recommended you make a backup of the modified configuration file. This is done by saving the modified ini configuration...
Page 38 - Monitoring; LEDs
MP-11x & Microsoft Office Communications Server 2007 Quick Installation Guide 38 Document #: LTRT-26301 5 Monitoring the Gateway The gateway provides several methods to monitor various operating statuses: Monitoring the gateway's front-panel chassis LEDs (refer to Section 5.1 ). Monitoring t...
Page 39 - Monitoring the Channels; To monitor the status of the channels, take this step:
Quick Installation Guide 5. Monitoring the Gateway Version 5.0 39 September 2007 5.2 Monitoring the Channels You can monitor channels using the gateway's Embedded Web Server. ¾ To monitor the status of the channels, take this step: Open the 'Channel Status' screen, by clicking the Home icon on the...
Page 40 - Troubleshooting; To restore factory default settings, take these 3 steps:; Debugging using a Syslog Server
MP-11x & Microsoft Office Communications Server 2007 Quick Installation Guide 40 Document #: LTRT-26301 6 Troubleshooting 6.1 General Troubleshooting The table below lists general troubleshooting that may arise with your gateway. Table 6-1: General Troubleshooting Problem Possible Cause Solution...
Page 41 - To configure the Syslog parameters, take these 7 steps:
Quick Installation Guide 6. Troubleshooting Version 5.0 41 September 2007 ¾ To configure the Syslog parameters, take these 7 steps: 1. Open the ‘Management Settings’ screen ( Advanced Configuration menu > Management Settings ); the ‘Management Settings’ screen is displayed. Figure 6-1: Management...
Page 42 - Regulatory; Declaration of Conformity
MP-11x & Microsoft Office Communications Server 2007 Quick Installation Guide 42 Document #: LTRT-26301 7 Regulatory Information Declaration of Conformity Application of Council Directives: 73/23/EEC (including amendments) 89/336/EEC (including amendments) 1999/5/EC Annex-II of the Directive Sta...
Page 43 - Safety; FCC Statement
Quick Installation Guide 7. Regulatory Information Version 5.0 43 September 2007 Safety Notices • Installation and service of this unit must only be performed by authorized, qualified service personnel. • The MediaPack FXO Output Tones and DTMF level should not exceed -9 dBm (AudioCodes setting #23)...
Page 44 - MediaPack
™ MediaPack MP-118 & MP-114 Quick Installation Guide Integration with Microsoft ® Office Communications Server 2007 www.audiocodes.com