Page 2 - Trademarks; 01 Explorer Boulevard
Trademarks TRACER 6000 Series Integrated System Manual 2 Copyright © 2005 ADTRAN, Inc. 612806420L1-1F Trademarks Any brand names and product names included in this manual are trademarks, registered trademarks, or trade names of their respective holders. To the Holder of the Manual The contents of th...
Page 3 - Revision History; Document; Added new real-time power reporting and support for new; Notes provide additional useful information.
TRACER 6000 Series Integrated System Manual Revision History 612806420L1-1F Copyright © 2005 ADTRAN, Inc. 3 Revision History Document Revision Date Description of Changes A December 2004 Initial release of manual to include the TRACER 6420 (5.8 GHz integrated system) and the Quad T1 and Ethernet Swi...
Page 4 - Safety Instructions; risk of shock from lightning.; Save These Important Safety Instructions
Safety Instructions TRACER 6000 Series Integrated System Manual 4 Copyright © 2005 ADTRAN, Inc. 612806420L1-1F Safety Instructions When using your telephone equipment, please follow these basic safety precautions to reduce the risk of fire, electrical shock, or personal injury: 1. Do not use this pr...
Page 5 - FCC-Required Information; Radio Frequency Interface Statement; Consult the dealer or an experienced radio/TV technician for help.
TRACER 6000 Series Integrated System Manual FCC-Required Information 612806420L1-1F Copyright © 2005 ADTRAN, Inc. 5 FCC-Required Information Federal Communications Commission Radio Frequency Interference Statement This equipment has been tested and found to comply with the limits for a Class A digit...
Page 6 - FCC Output Power Restrictions; This device must be professionally installed; Exposure to Radio Frequency Fields; The following precautions must be taken
FCC-Required Information TRACER 6000 Series Integrated System Manual 6 Copyright © 2005 ADTRAN, Inc. 612806420L1-1F FCC Output Power Restrictions The FCC does not require licensing to implement this device. License-free operation in the industrial, scientific, and medical band is documented in FCC R...
Page 7 - Repair and Return; CaPS Department
TRACER 6000 Series Integrated System Manual Warranty and Customer Service Information 612806420L1-1F Copyright © 2005 ADTRAN, Inc. 7 Warranty, Customer Service, Product Support Information, and Training ADTRAN will repair and return this product within the warranty period if it does not meet its pub...
Page 8 - Training
Warranty and Customer Service Information TRACER 6000 Series Integrated System Manual 8 Copyright © 2005 ADTRAN, Inc. 612806420L1-1F Post-Sale Support Your reseller should serve as the first point of contact for support. If additional support is needed, the ADTRAN Support website provides a variety ...
Page 9 - Table of Contents; TRACER 64x0. This section also lists traps supported for each MIB.
TRACER 6000 Series Integrated System Manual Table of Contents 612806420L1-1F Copyright © 2005 ADTRAN, Inc. 9 Table of Contents Section 1 System Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11 This section of ADTRAN’s TRACER 6000 Series Integrated System...
Page 11 - SYSTEM DESCRIPTION; Engineering Guidelines; ONTENTS; E1 Network Module with 75
612806420L1-1F Copyright © 2005 ADTRAN, Inc. 11 SYSTEM DESCRIPTION This section of ADTRAN’s TRACER 6000 Series Integrated System Manual is designed for use by network engineers, planners, and designers for overview information about the TRACER 64x0 systems. It contains general information and descri...
Page 12 - SYSTEM OVERVIEW; port). SNMP traps are implemented for all RF link and; CRAFT; FEATURES AND BENEFITS; No license required per FCC Rules Part 15.247
Section 1 System Description TRACER 6000 Series Integrated System Manual 12 Copyright © 2005 ADTRAN, Inc. 612806420L1-1F 1. SYSTEM OVERVIEW The TRACER 64x0 provides license-free scalable connectivity for service providers and corporate networks. These radios feature two modular network interface por...
Page 15 - MICROWAVE PATH ENGINEERING BASICS
612806420L1-1F Copyright © 2005 ADTRAN, Inc. 15 MICROWAVE PATH ENGINEERING BASICS Explains the basics of analyzing a wireless microwave link or path. Defines significant parameters and makes several installation recommendations. C ONTENTS Line-of-Sight . . . . . . . . . . . . . . . . . . . . . . . ....
Page 16 - Terminology; is a power level (in watts), the decibel equivalent is defined as; CALCULATING THE FADE MARGIN; d B
Section 2 Microwave Path Engineering Basics TRACER 6000 Series Integrated System Manual 16 Copyright © 2005 ADTRAN, Inc. 612806420L1-1F 1. LINE-OF-SIGHT The TRACER 6410 and TRACER 6420 systems are designed for operation in the license-free 2.400 to 2.483 GHz and 5.725 GHz to 5.850 GHz industrial, sc...
Page 17 - RECEIVER POWER; where the variables in the equations are defined as
TRACER 6000 Series Integrated System Manual Section 2 Microwave Path Engineering Basics 612806420L1-1F Copyright © 2005 ADTRAN, Inc. 17 where the variables in the equations are defined as P R received power (dBm) P sens receiver sensitivity (dBm) P T transmitted power (adjustable up to 20, 24, or 27...
Page 18 - Figure 1. Example Microwave Path with Parameters; Antenna Gain; where
Section 2 Microwave Path Engineering Basics TRACER 6000 Series Integrated System Manual 18 Copyright © 2005 ADTRAN, Inc. 612806420L1-1F Figure 1 illustrates a wireless link configuration containing all the parameters necessary for the power budget analysis. Figure 1. Example Microwave Path with Para...
Page 19 - Dish Diameter
TRACER 6000 Series Integrated System Manual Section 2 Microwave Path Engineering Basics 612806420L1-1F Copyright © 2005 ADTRAN, Inc. 19 Table 1. Antenna Gain for Given Dish Diameters with k = 0.55 (Standard) Dish Diameter (in feet) Gain at 2.4 GHz (in dBi) Gain at 5.8 GHz (in dBi) 2 21.1 28.8 4 27.2...
Page 20 - Table 5. Transmit Power Reduction for Various Antennae Gains
Section 2 Microwave Path Engineering Basics TRACER 6000 Series Integrated System Manual 20 Copyright © 2005 ADTRAN, Inc. 612806420L1-1F Transmitted Power (P T ) The FCC specifies the maximum transmitter power used for antennae of a given gain. FCC Rules Part 15, Subpart 247 allow for a maximum power...
Page 21 - Table 6. Typical Coaxial Loss for Common Cable Types; Cable Type
TRACER 6000 Series Integrated System Manual Section 2 Microwave Path Engineering Basics 612806420L1-1F Copyright © 2005 ADTRAN, Inc. 21 Path Distance (d) The path distance is the physical distance between the transmit and receive antennas. For the TRACER 64x0, these distances can range up to 30 mile...
Page 22 - Path Length
Section 2 Microwave Path Engineering Basics TRACER 6000 Series Integrated System Manual 22 Copyright © 2005 ADTRAN, Inc. 612806420L1-1F Path Loss (L P ) Path loss is the estimated attenuation between the transmit and receive antennas caused by signal separation and scattering. The path loss is consi...
Page 23 - RECEIVER SENSITIVITY; xE1 or 8 Mbps Ethernet
TRACER 6000 Series Integrated System Manual Section 2 Microwave Path Engineering Basics 612806420L1-1F Copyright © 2005 ADTRAN, Inc. 23 5. RECEIVER SENSITIVITY Receiver sensitivity is a value expressed in decibels referenced to one milliwatt (dBm) that corresponds to the minimum amount of signal pow...
Page 24 - ANTENNA INFORMATION; GND; Real-time Signal Values; The TRACER 64x0 system displays real-time signal values for
Section 2 Microwave Path Engineering Basics TRACER 6000 Series Integrated System Manual 24 Copyright © 2005 ADTRAN, Inc. 612806420L1-1F 6. ANTENNA INFORMATION The overall wireless system is directly affected by the antenna selection and installation, discussed in the following sections. Antenna Alig...
Page 25 - Antenna Beam Patterns; Figure 2. Typical Antenna Beam Pattern; Fresnel Zones, Earth Curvature, and Antenna Heights; main lobe
TRACER 6000 Series Integrated System Manual Section 2 Microwave Path Engineering Basics 612806420L1-1F Copyright © 2005 ADTRAN, Inc. 25 Antenna Beam Patterns Antennas used with the TRACER 64x0 system have a particular beam shape, determined in part by the physical construction and geometry of the an...
Page 27 - OTHER CONSIDERATIONS; where the parameters are; Table 11. Minimum Antenna Height for Given Path Lengths (km and m); a b f d
TRACER 6000 Series Integrated System Manual Section 2 Microwave Path Engineering Basics 612806420L1-1F Copyright © 2005 ADTRAN, Inc. 27 7. OTHER CONSIDERATIONS Path Availability The path availability of a wireless link is a metric that expresses the fractional amount of time a link is available over...
Page 29 - ENGINEERING GUIDELINES
612806420L1-1F Copyright © 2005 ADTRAN, Inc. 29 ENGINEERING GUIDELINES Provides information to assist network designers with incorporating the TRACER 64x0 system into their networks. C ONTENTS Equipment Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ...
Page 30 - EQUIPMENT DIMENSIONS; The front panel contains an; RSSI; monitoring interface, a; interface for reference with RSSI, a; TEST; for management and configuration, an
Section 3 Engineering Guidelines TRACER 6000 Series Integrated System Manual 30 Copyright © 2005 ADTRAN, Inc. 612806420L1-1F 1. EQUIPMENT DIMENSIONS The TRACER 64x0 integrated radio is 17.2 inch (43.7 cm) W, 11.4 inch (28.9 cm) D, and 1.7 inch (4.4 cm) H, weighs 7 pounds (3.18 kg), and can be used i...
Page 31 - Table 1. TRACER 64x0 Front Panel Description; PWR; TEMP; TST
TRACER 6000 Series Integrated System Manual Section 3 Engineering Guidelines 612806420L1-1F Copyright © 2005 ADTRAN, Inc. 31 RSSI Monitoring Interface The RSSI voltage is a function of the signal strength at the receiver and is used to measure the received signal strength. RSSI varies from approxima...
Page 32 - The; STATUS; Table 3. AUX RS232 Pinout
Section 3 Engineering Guidelines TRACER 6000 Series Integrated System Manual 32 Copyright © 2005 ADTRAN, Inc. 612806420L1-1F AUX RS232 Interface (RJ-45) The AUX RS232 interface provides a female RJ-45 terminal connection (wired as a DCE interface), used for a 9600 bps point-to-point connection betwe...
Page 33 - REVIEWING THE TRACER 64X0 REAR PANEL DESIGN; Name
TRACER 6000 Series Integrated System Manual Section 3 Engineering Guidelines 612806420L1-1F Copyright © 2005 ADTRAN, Inc. 33 CRAFT Port (DB-9) The CRAFT connector provides a female DB-9 terminal connection (wired as a DCE interface), used for terminal access to the TRACER system. Table 4 shows the p...
Page 35 - Fuse; NC; Microwave Path Engineering Basics
TRACER 6000 Series Integrated System Manual Section 3 Engineering Guidelines 612806420L1-1F Copyright © 2005 ADTRAN, Inc. 35 DC Power Connection (Plug-In Terminal Block) The TRACER 64x0 can operate from a supply between 21 and 60 VDC, with either polarity referenced to ground, and consumes less than...
Page 36 - Applying power to the radio without a 50
Section 3 Engineering Guidelines TRACER 6000 Series Integrated System Manual 36 Copyright © 2005 ADTRAN, Inc. 612806420L1-1F loss factors. Applying power to the radio without a 50 Ω load attached to the antenna interface can damage the system. Verify the 50 Ω load is attached before powering the rad...
Page 38 - Interface RJ-45 Connector Pinout
Section 3 Engineering Guidelines TRACER 6000 Series Integrated System Manual 38 Copyright © 2005 ADTRAN, Inc. 612806420L1-1F 4xE1 Module with 120 Ω Interface The 4xE1 network module provides four E1 interfaces (through four RJ-45 connectors) that provide the following functions: • AMI or HDB3 coding...
Page 40 - Figure 4. E1 Breakout Panel; Hardware; Receiver
Section 3 Engineering Guidelines TRACER 6000 Series Integrated System Manual 40 Copyright © 2005 ADTRAN, Inc. 612806420L1-1F Figure 4. E1 Breakout Panel 6. AT-A-GLANCE SPECIFICATIONS Table 15 on page 40 contains a list of specifications for the TRACER 64x0 system. Table 15. At-A-Glance Specification...
Page 43 - NETWORK TURNUP PROCEDURE
612806420L1-1F Copyright © 2005 ADTRAN, Inc. 43 NETWORK TURNUP PROCEDURE Provides shipment contents list, grounding instructions, mounting options, and specifics of supplying power to the unit. C ONTENTS Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ....
Page 44 - INTRODUCTION; Customer Service, Product Support Information, and Training; Contents of Shipment
Section 4 Network Turnup Procedure TRACER 6000 Series Integrated System Manual 44 Copyright © 2005 ADTRAN, Inc. 612806420L1-1F 1. INTRODUCTION This section discusses TRACER 64x0 system installation. 2. TOOLS REQUIRED The tools required for TRACER 64x0 installation are: • VT100 terminal or PC with te...
Page 45 - Customer Provides; Base System
TRACER 6000 Series Integrated System Manual Section 4 Network Turnup Procedure 612806420L1-1F Copyright © 2005 ADTRAN, Inc. 45 Your Quad T1 module shipment includes the following items: • Quad T1 module • Quad T1 module quick start guide Your Quad Ethernet Switch module shipment includes the followi...
Page 46 - CHANNEL SELECTION; Warranty, Customer Service, Product Support Information, and; Channel A
Section 4 Network Turnup Procedure TRACER 6000 Series Integrated System Manual 46 Copyright © 2005 ADTRAN, Inc. 612806420L1-1F 4. CHANNEL SELECTION The FCC has allocated 83.5 MHz of spectrum in the 2.4 GHz band where the TRACER 6410 operates, and 125 MHz of spectrum in the 5.8 GHz band where the TRA...
Page 47 - GROUNDING INSTRUCTIONS
TRACER 6000 Series Integrated System Manual Section 4 Network Turnup Procedure 612806420L1-1F Copyright © 2005 ADTRAN, Inc. 47 5. GROUNDING INSTRUCTIONS The following paragraphs provide grounding instruction information from the Underwriters’ Laboratory UL60950 Standard for Safety of Information Tec...
Page 48 - SUPPLYING POWER TO THE UNIT; MOUNTING OPTIONS; Power to the TRACER 64x0 DC system must be from a reliably grounded; Instructions for Rack Mounting the TRACER 64x0
Section 4 Network Turnup Procedure TRACER 6000 Series Integrated System Manual 48 Copyright © 2005 ADTRAN, Inc. 612806420L1-1F 6. SUPPLYING POWER TO THE UNIT The TRACER 64x0 can operate from an LPS or Class 2 power source between 21 and 60 VDC and a minimum output current rating of 1.2 A, with eithe...
Page 49 - Figure 3. 19-inch Rackmount Illustration
TRACER 6000 Series Integrated System Manual Section 4 Network Turnup Procedure 612806420L1-1F Copyright © 2005 ADTRAN, Inc. 49 Figure 3. 19-inch Rackmount Illustration Figure 4. 23-inch Rackmount Illustration TRA CER 6420 TR AC ER 64 20
Page 50 - INSTALLING MODULES; Figure 5. TRACER 64x0 Network Module Slot Designation; Instructions for Installing Network Modules; MODULE 1
Section 4 Network Turnup Procedure TRACER 6000 Series Integrated System Manual 50 Copyright © 2005 ADTRAN, Inc. 612806420L1-1F 8. INSTALLING MODULES Figure 5 shows the slot numbering designation as viewed from the rear of the TRACER 64x0. The functionally identical option slots only accept TRACER 60...
Page 51 - CONNECTING THE MODULE INTERFACES; TO RADIO; connector, and then attach the other end of the cable (labeled; TO PANEL; Remove power from the unit.
TRACER 6000 Series Integrated System Manual Section 4 Network Turnup Procedure 612806420L1-1F Copyright © 2005 ADTRAN, Inc. 51 9. CONNECTING THE MODULE INTERFACES Quad T1 Module Interfaces The physical T1 interfaces are provided using four RJ-45 ports located on the module. Straight-through T1 inter...
Page 52 - Figure 6. E1 Connection with Breakout Panel
Section 4 Network Turnup Procedure TRACER 6000 Series Integrated System Manual 52 Copyright © 2005 ADTRAN, Inc. 612806420L1-1F Figure 6. E1 Connection with Breakout Panel 1 2
Page 53 - USER INTERFACE GUIDE
612806420L1-1F Copyright © 2005 ADTRAN, Inc. 53 USER INTERFACE GUIDE Provides detailed descriptions of all menu options and configuration parameters available for the TRACER 64x0. This section of the TRACER 6000 Series Integrated System Manual is designed for use by network administrators and others...
Page 55 - NAVIGATING THE TERMINAL MENU; CRAFT PORT; for proper; password; Terminal Menu Window; Figure 1. Main Menu Screen; All TRACER 64x0 passwords are case-sensitive.
TRACER 6000 Series Integrated System Manual Section 5 User Interface Guide 612806420L1-1F Copyright © 2005 ADTRAN, Inc. 55 1. NAVIGATING THE TERMINAL MENU The TRACER 64x0 menu system can be accessed with a VT100 compatible terminal that is connected to the CRAFT PORT (located on the front of the uni...
Page 56 - Navigating using the Keyboard Keys; Moving Through the Menus; MENU AND SYSTEM CONTROL
Section 5 User Interface Guide TRACER 6000 Series Integrated System Manual 56 Copyright © 2005 ADTRAN, Inc. 612806420L1-1F Navigating using the Keyboard Keys You can use various keystrokes to move through the terminal menu, to manage a terminal menu session, and to configure the system. Moving Throu...
Page 57 - MENU DESCRIPTIONS; YSTEM; through
TRACER 6000 Series Integrated System Manual Section 5 User Interface Guide 612806420L1-1F Copyright © 2005 ADTRAN, Inc. 57 3. MENU DESCRIPTIONS The remainder of this section describes the TRACER 64x0 menus and submenus. > S YSTEM S TATUS Figure 2 shows the TRACER 64x0 System Status menu page. The...
Page 59 - is; K. Navigation Reminders; Navigating the; AIN
TRACER 6000 Series Integrated System Manual Section 5 User Interface Guide 612806420L1-1F Copyright © 2005 ADTRAN, Inc. 59 I. Rx Power Displays the approximate receiver levels (for both the local and remote units) using a series of symbols ( # ) and the actual real-time value (in dBm). The more symb...
Page 60 - Figure 3. TRACER 64x0 Main Menu; TRACER 64x0 Main menu page.
Section 5 User Interface Guide TRACER 6000 Series Integrated System Manual 60 Copyright © 2005 ADTRAN, Inc. 612806420L1-1F Figure 3. TRACER 64x0 Main Menu From the keyboard, use the up and down arrow keys to scroll through the available pages, or enter the number or letter of the selected page (to h...
Page 61 - when
TRACER 6000 Series Integrated System Manual Section 5 User Interface Guide 612806420L1-1F Copyright © 2005 ADTRAN, Inc. 61 Figure 4. TRACER 64x0 System Configuration > S YSTEM C ONFIGURATION > S ITE N AME Provides a user-defined alphanumeric description (up to 25 characters) for the TRACER 64x...
Page 62 - Are you sure you want to restore factory Defaults? Y or N
Section 5 User Interface Guide TRACER 6000 Series Integrated System Manual 62 Copyright © 2005 ADTRAN, Inc. 612806420L1-1F > S YSTEM C ONFIGURATION > CRAFT P ORT B AUD Specifies the baud rate of the port. Select either 9600 (default), 19200 , 38400 , 57600 , or 115200 bps. If you are using the...
Page 63 - displays in
TRACER 6000 Series Integrated System Manual Section 5 User Interface Guide 612806420L1-1F Copyright © 2005 ADTRAN, Inc. 63 > RF L INK C ONFIGURATION Figure 5 shows the TRACER 64x0 RF Link Configuration menu page, which contains the transmit and receive power settings and band plan configuration f...
Page 64 - INK
Section 5 User Interface Guide TRACER 6000 Series Integrated System Manual 64 Copyright © 2005 ADTRAN, Inc. 612806420L1-1F > RF L INK C ONFIGURATION > RF B AND P LAN Sets the band plan for the TRACER 64x0. Each frequency plan is divided into three band plans (1, 2, or 3). Both local and remote...
Page 65 - is set to
TRACER 6000 Series Integrated System Manual Section 5 User Interface Guide 612806420L1-1F Copyright © 2005 ADTRAN, Inc. 65 > RF L INK C ONFIGURATION > L INK E NCRYPTION The TRACER 64x0 provides triple-DES (3DES) encryption of the data passed over the RF Link. When L INK E NCRYPTION is set to E...
Page 66 - path or interference problems.
Section 5 User Interface Guide TRACER 6000 Series Integrated System Manual 66 Copyright © 2005 ADTRAN, Inc. 612806420L1-1F > RF L INK E RROR H ISTORY Figure 9 shows the TRACER 64x0 main RF Link Error History menu page, which displays detailed error statistics for the RF link (from both the local ...
Page 67 - The received power level (
TRACER 6000 Series Integrated System Manual Section 5 User Interface Guide 612806420L1-1F Copyright © 2005 ADTRAN, Inc. 67 Figure 10. RF Link Max/Min Received Power History The received power level ( MIN and MAX ) represents the minimum and maximum values of received signal levels in 24-hour or 15-m...
Page 68 - The received power quality level (; Days
Section 5 User Interface Guide TRACER 6000 Series Integrated System Manual 68 Copyright © 2005 ADTRAN, Inc. 612806420L1-1F Figure 11. RF Link Min/Max Received Signal Quality History The received power quality level ( MIN and MAX ) represents the minimum and maximum values of received signal quality ...
Page 69 - total active channels.; Defines the active channels (
TRACER 6000 Series Integrated System Manual Section 5 User Interface Guide 612806420L1-1F Copyright © 2005 ADTRAN, Inc. 69 > D ATAPATH P ROVISIONING Figure 12 shows the Datapath Provisioning menu page, which displays the active network interfaces for the installed modules (from both the local and...
Page 70 - The following menus for the; apply to all four
Section 5 User Interface Guide TRACER 6000 Series Integrated System Manual 70 Copyright © 2005 ADTRAN, Inc. 612806420L1-1F > 4 X E1 M ODULE C ONFIGURATION /S TATUS /H ISTORY (M AIN S CREEN ) Figure 13 shows the TRACER 64x0 E1 Module Configuration main screen, which contains access to the status, ...
Page 71 - Troubleshooting Guide
TRACER 6000 Series Integrated System Manual Section 5 User Interface Guide 612806420L1-1F Copyright © 2005 ADTRAN, Inc. 71 > E1 X S TATUS /C ONFIGURATION /L OOPBACK > E1 X I NTERFACE A LARMS Displays any active alarms on the E1 link (reported from both the local and remote TRACER 64x0 units). ...
Page 72 - ) line coding. HDB3 coding does not allow more than three; the connected E1 equipment.
Section 5 User Interface Guide TRACER 6000 Series Integrated System Manual 72 Copyright © 2005 ADTRAN, Inc. 612806420L1-1F > E1 X S TATUS /C ONFIGURATION /L OOPBACK > L INE C ODE Sets the line coding for the E1 link. The TRACER 64x0 supports high-density bipolar 3 substitution ( HDB3 ) and alt...
Page 73 - loopback to test data path integrity from the; Hours
TRACER 6000 Series Integrated System Manual Section 5 User Interface Guide 612806420L1-1F Copyright © 2005 ADTRAN, Inc. 73 > E1 X S TATUS /C ONFIGURATION /L OOPBACK > L OOP /N ORMAL S TATE > L INE [R EMOTE ] Activates a loopback at the remote TRACER 64x0 E1 framer towards the connected E1 e...
Page 76 - connected T1 equipment.
Section 5 User Interface Guide TRACER 6000 Series Integrated System Manual 76 Copyright © 2005 ADTRAN, Inc. 612806420L1-1F > T1 X S TATUS /C ONFIGURATION /L OOPBACK > L OOP /N ORMAL S TATE > N ORMAL Defines the T1 link as normal data transport mode; there are no active loopbacks. > T1 X ...
Page 77 - Press
TRACER 6000 Series Integrated System Manual Section 5 User Interface Guide 612806420L1-1F Copyright © 2005 ADTRAN, Inc. 77 > T1 X P ERFORMANCE H ISTORY Figure 26 shows the T1x Performance History menu page, which displays detailed error statistics for the T1 link (from both the local and remote T...
Page 78 - apply to all four available
Section 5 User Interface Guide TRACER 6000 Series Integrated System Manual 78 Copyright © 2005 ADTRAN, Inc. 612806420L1-1F > E THERNET S WITCH M ODULE C ONFIGURATION /S TATUS /H ISTORY (M AIN S CREEN ) Figure 27 shows the Ethernet Switch Module Configuration/Status/History main screen, which cont...
Page 79 - from the
TRACER 6000 Series Integrated System Manual Section 5 User Interface Guide 612806420L1-1F Copyright © 2005 ADTRAN, Inc. 79 >E THERNET S WITCH C ONFIGURATION > P ORT X The Quad Ethernet Switch module provides the capability to individually disable interfaces on the module. Selecting D ISABLE fr...
Page 82 - public; Ethernet interface.
Section 5 User Interface Guide TRACER 6000 Series Integrated System Manual 82 Copyright © 2005 ADTRAN, Inc. 612806420L1-1F > M ANAGEMENT /SNMP P ORT C ONFIGURATION > SNMP G ET C OMMUNITY Defines the community name for Get access (to poll the TRACER 64x0 for status information). This value must...
Page 83 - default value is 4, and the maximum value is 99.; The number of ping requests transmitted.; The number of ping requests that did not receive replies.
TRACER 6000 Series Integrated System Manual Section 5 User Interface Guide 612806420L1-1F Copyright © 2005 ADTRAN, Inc. 83 > P ING U TILITY > N UMBER OF P ACKETS Specifies the number of ping packets to send to the IP address specified in the P ING A DDRESS field. The default value is 4, and th...
Page 84 - MGMT P; XMODEM; interface of the local system.
Section 5 User Interface Guide TRACER 6000 Series Integrated System Manual 84 Copyright © 2005 ADTRAN, Inc. 612806420L1-1F > F IRMWARE U PGRADE U TILITY Figure 33 shows the Firmware Upgrade Utility menu page, which contains the parameters for performing a firmware upgrade for the local and remote...
Page 85 - IDU
TRACER 6000 Series Integrated System Manual Section 5 User Interface Guide 612806420L1-1F Copyright © 2005 ADTRAN, Inc. 85 > F IRMWARE U PGRADE U TILITY > U PGRADE D ESTINATION Specify the unit to upgrade. The following options are available: > F IRMWARE U PGRADE U TILITY > C OMMAND Use ...
Page 86 - and Ethernet traffic is
Section 5 User Interface Guide TRACER 6000 Series Integrated System Manual 86 Copyright © 2005 ADTRAN, Inc. 612806420L1-1F > RF L INK M ANAGEMENT B RIDGE C ONFIGURATION Figure 34 shows the RF Link Bridge Configuration menu page, which contains the parameters for enabling and configuring the TRACE...
Page 87 - indicates that the system detects a valid RF link and
TRACER 6000 Series Integrated System Manual Section 5 User Interface Guide 612806420L1-1F Copyright © 2005 ADTRAN, Inc. 87 >RF L INK M ANAGEMENT B RIDGE C ONFIGURATION > I NACTIVITY T IMEOUT Defines the amount of time that an Ethernet address is maintained in the bridge table. A shorter time p...
Page 88 - failure activates the main alarm relay on the TRACER 64x0
Section 5 User Interface Guide TRACER 6000 Series Integrated System Manual 88 Copyright © 2005 ADTRAN, Inc. 612806420L1-1F displays only during an active alarm condition. Once the condition has cleared, the speed alarm is cleared from the display. A F AN H AS F AILED display indicates that the fan h...
Page 89 - DETAIL LEVEL PROCEDURES
612806420L1-1F Copyright © 2005 ADTRAN, Inc. 89 DETAIL LEVEL PROCEDURES Provides detailed instructions on performing common system tasks such as connecting to the system and upgrading firmware. C ONTENTS DLP-1 Connecting a VT100 Terminal or PC to the CRAFT Port. . . . . . . . . . . . . . . . . . . ....
Page 91 - Connecting a VT100 Terminal or PC to the CRAFT Port; Introduction; Prerequisite Procedures; An appropriate cable to connect the TRACER 64x0 to a terminal
612806420L1-1F Copyright © 2005 ADTRAN, Inc. 91 DLP-1 Connecting a VT100 Terminal or PC to the CRAFT Port Introduction TRACER 64x0 management and provisioning are facilitated by a series of intuitive menus that are accessible on a computer screen. Connecting either a VT100 terminal or a PC with term...
Page 93 - Logging into the TRACER 64x0
612806420L1-1F Copyright © 2005 ADTRAN, Inc. 93 DLP-2 Logging into the TRACER 64x0 Introduction Once you are connected to the TRACER 64x0, you must log into the system to gain access to the management and provisioning functions. This DLP assumes you are connected to the TRACER 64x0 and provides spec...
Page 94 - Perform the steps below in the order listed.
Section 6 DLP-2 TRACER 6000 Series Integrated System Manual 94 Copyright © 2005 ADTRAN, Inc. 612806420L1-1F 1. After connecting to the system, press any key to display the L OGIN screen shown here. The flashing cursor at the L OGIN field indicates that a password must be entered. 2. Enter the passwo...
Page 95 - Setting IP Parameters for the TRACER 64x0; IP
612806420L1-1F Copyright © 2005 ADTRAN, Inc. 95 DLP-3 Setting IP Parameters for the TRACER 64x0 Introduction If the TRACER 64x0 is connected to an IP network for Telnet, TFTP, or SNMP management, several IP parameters must be set for the unit to communicate with the network. These parameters are des...
Page 96 - Enter
Section 6 DLP-3 TRACER 6000 Series Integrated System Manual 96 Copyright © 2005 ADTRAN, Inc. 612806420L1-1F 1. Log into the system with maximum rights (details are in DLP-2, Logging into the TRACER 64x0 , on page 93). 2. Press m to activate the Main menu page. From the Main menu page, press 7 to sel...
Page 97 - Verifying
TRACER 6000 Series Integrated System Manual Section 6 DLP-3 612806420L1-1F Copyright © 2005 ADTRAN, Inc. 97 4. From the M ANAGEMENT /SNMP C ONFIGURATION menu page, select the IP A DDRESS field and press < Enter >. Type the IP address provided by your network manager and press < Enter > t...
Page 98 - TRACER 6000 Series Integrated System Manual
Section 6 DLP-3 TRACER 6000 Series Integrated System Manual 98 Copyright © 2005 ADTRAN, Inc. 612806420L1-1F
Page 99 - Verifying Communications Over an IP LAN; MGMT; port is connected to a local area network (LAN), test steps must be; Tools and Materials Required; Access to a PC or other computer connected to the LAN
612806420L1-1F 99 DLP-4 Verifying Communications Over an IP LAN Introduction When the 10/100BaseT/TX MGMT port is connected to a local area network (LAN), test steps must be performed on the TRACER 64x0 to ensure that the unit is communicating properly over the network. This procedure outlines those...
Page 101 - to logout of
TRACER 6000 Series Integrated System Manual Section 6 DLP-4 612806420L1-1F 101 3. Telnet to the TRACER 64x0. From the same computer used in the previous step, Telnet to the TRACER 64x0 and verify that the Telnet session is properly opened. Once the Telnet session is established, press <Ctrl+z>...
Page 103 - Updating the Firmware Using TFTP; interface. This DLP provides the steps for a successful; Updating the Firmware Using XMODEM; A PC with Telnet client software
612806420L1-1F Copyright © 2005 ADTRAN, Inc. 103 DLP-5 Updating the Firmware Using TFTP Introduction The TRACER 64x0 supports firmware updates using TFTP or XMODEM. Use the 10/100BaseT/TX MGMT Ethernet port and TFTP from a network server or XMODEM (if your Telnet client supports file transfers), or ...
Page 105 - SC T
TRACER 6000 Series Integrated System Manual Section 6 DLP-5 612806420L1-1F Copyright © 2005 ADTRAN, Inc. 105 U PGRADE I MAGE IS I NVALID Indicates that the system image was not verified as a valid image for the specified update. Before the firmware upgrade begins, the TRACER 64x0 verifies that the i...
Page 109 - MIBS
612806420L1-1F Copyright © 2005 ADTRAN, Inc. 109 MIBS Provides a listing of SNMP Management Information Bases (MIBs) supported by the TRACER 64x0. This section also lists traps supported for each MIB. C ONTENTS MIBs Supported by the TRACER 64x0 . . . . . . . . . . . . . . . . . . . . . . . . . . . ....
Page 110 - MIBS SUPPORTED BY THE TRACER 64x0; Table 1 lists the MIBs supported by the TRACER 64x0.; MIB COMPILATION ORDER; MIBs are compiled in the order shown in Table 2.; Table 1. MIBs Supported by the TRACER 64x0
Section 7 MIBs TRACER 6000 Series Integrated System Manual 110 Copyright © 2005 ADTRAN, Inc. 612806420L1-1F 1. MIBS SUPPORTED BY THE TRACER 64x0 Table 1 lists the MIBs supported by the TRACER 64x0. 2. MIB COMPILATION ORDER MIBs are compiled in the order shown in Table 2. Table 1. MIBs Supported by t...
Page 111 - TRAPS SUPPORTED BY THE TRACER 64x0; The TRACER 64x0 supports the traps described in Table 3.; Table 3. Traps Supported by the TRACER 64x0
TRACER 6000 Series Integrated System Manual Section 7 MIBs 612806420L1-1F Copyright © 2005 ADTRAN, Inc. 111 3. TRAPS SUPPORTED BY THE TRACER 64x0 The TRACER 64x0 supports the traps described in Table 3. Table 3. Traps Supported by the TRACER 64x0 MIB Trap This trap indicates that.... TRACER6000.mib ...
Page 114 - MIB VARIABLES SUPPORTED BY THE TRACER 64X0
Section 7 MIBs TRACER 6000 Series Integrated System Manual 114 Copyright © 2005 ADTRAN, Inc. 612806420L1-1F 4. MIB VARIABLES SUPPORTED BY THE TRACER 64X0 Table 4. MIB Variables for ad.mi2 ad adProducts adProductInfo adProdName DisplayString RO adProdPartNumber DisplayString RO adProdCLEIcode Display...
Page 115 - Table 6. MIB Variables for TRACER6000.mib
TRACER 6000 Series Integrated System Manual Section 7 MIBs 612806420L1-1F Copyright © 2005 ADTRAN, Inc. 115 adDS1CurrentArm Integer RW adDS1TotalArm Integer RW adDS1FarCurrentArm Integer RW adDS1FarTotalArm Integer RW adDS1CurrentThreshold adDS1CurrentThrsES Integer RW adDS1CurrentThrsSES Integer RW...
Page 117 - * Listed variable only applies to TRACER high power systems.
TRACER 6000 Series Integrated System Manual Section 7 MIBs 612806420L1-1F Copyright © 2005 ADTRAN, Inc. 117 adTRACERswitchWanStatusTable adTRACERswitchWanStatusEntry AdTRACERswitchWanStatusEntry adTRACERswitchWanStatusIdx Integer RO adTRACERswitchWanTxPackets Integer RO adTRACERswitchWanTxPacketsDro...
Page 125 - TROUBLESHOOTING GUIDE
612806420L1-1F Copyright © 2005 ADTRAN, Inc. 125 TROUBLESHOOTING GUIDE Provides helpful information for troubleshooting common configuration problems for the TRACER 64x0. C ONTENTS Overview. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ....
Page 127 - RF LOW LED; RF LOW; T1 Interface Alarms; LOS Alarm or Red Alarm; LOS A; Yellow Alarm
TRACER 6000 Series Integrated System Manual Section 8 Troubleshooting Guide 612806420L1-1F Copyright © 2005 ADTRAN, Inc. 127 RF LOW LED If the RF LOW LED is ON (solid red), the received signal is approaching 0 V of RSSI. This condition is typically indicative of a path or installation problem. Recom...
Page 128 - BPV; E1 Interface Alarms; All active E1 alarms are displayed on the; AIS Alarm; AMI
Section 8 Troubleshooting Guide TRACER 6000 Series Integrated System Manual 128 Copyright © 2005 ADTRAN, Inc. 612806420L1-1F BPV Bipolar violations (BPVs) indicate an improper configuration or faulty wiring. Recommended Actions: 1. Verify the TRACER 64x0 unit and the attached equipment are configure...
Page 129 - CRC; System Alarms; Fan Speed Alarm; LAN LEDs; LAN; RF ERRORS
TRACER 6000 Series Integrated System Manual Section 8 Troubleshooting Guide 612806420L1-1F Copyright © 2005 ADTRAN, Inc. 129 CRC CRC errors indicate that the receiver is unable to synchronize to the CRC-4 frame pattern of the received E1 signal. Recommended Actions: 1. Verify the TRACER 64x0 unit an...
Page 130 - INSTALLING/TROUBLESHOOTING THE TRACER HARDWARE
Section 8 Troubleshooting Guide TRACER 6000 Series Integrated System Manual 130 Copyright © 2005 ADTRAN, Inc. 612806420L1-1F Nonviable path conditions could be caused by physical obstructions such as buildings, mountainous terrain, trees, etc., as well as other physical limitations such as excessive...
Page 132 - Installing/Configuring T1 Hardware; T1 Interface; Installing/Configuring E1 Hardware; E1 Interface; Installing/Configuring Ethernet Hardware; Quad Ethernet Switch Module
Section 8 Troubleshooting Guide TRACER 6000 Series Integrated System Manual 132 Copyright © 2005 ADTRAN, Inc. 612806420L1-1F 11. Command a link loopback on the remote TRACER 64x0 unit and run a test pattern from the connected T1 equipment. This will verify the data path across the RF link. Installin...