3M 8310 - Manual

3M 8310

3M 8310 – Manual, read for free online in PDF format. We hope this helps you resolve any issues you may have. If you have further questions, please contact us through the contact form.

1 Page 1
Page: / 1
Loading the manual
Page 1

1. Cup the respirator in your hand with the nosepiece at your fingertips allowing the

headbands to hang freely below your hand.

2. Position the respirator under your chin with the nosepiece up.

3. Pull the top strap over your head resting it high at the top back of your head. Pull the

bottom strap over your head and position it around the neck below the ears. Make
sure that the straps are not twisted.

4. Place the fingertips of both hands at the top of the metal nosepiece.

Mould the nosepiece to the shape of your nose by pushing inward while moving your
fingertips down both sides of the nosepiece.
Pinching the nosepiece using one hand may result in less effective respirator
performance.

5. The seal of the respirator on the face should be fit checked prior to wearing in the

work area.

3M 8300 Series Comfort Respirators

Respirator

Type

APF

VALVE

8310

FFP1 NR D

4

8312

FFP2 NR D

10

✓

8320

FFP1 NR D

4

8322

FFP2 NR D

10

✓

8833

FFP3 R D

20

✓

Standard: EN149:2001 + A1:2009
This respirator should not be used in oxygen deficient environments, for
escape purposes or by people with beards/ facial hair or in atmospheres
where concentrations of contaminant may exceed that deemed
Immediately Dangerous to Life and Health (IDLH).

Occupational Health & Environmental Safety Group
3M United Kingdom plc

3M Centre,

Cain Road, Bracknell

Berkshire RG12 8HT

Tel: 0870 60 800 60

www.3M.co.uk /ohes

3M Ireland Limited

The Iveagh Building

The Park

Carrickmines

Dublin 18

Tel: 1 800 320 500

Please recycle. Printed in UK.

© 3M 2009. All rights reserved.

3M Occupational Health & Environmental Safety Group

3M

™

8300 Series Comfort Respirators

Fitting Instructions

1

2

3

Fit Testing:

The 3M 8300 Series Respirator is a tight fitting facepiece and therefore

wearers require a fit test as per the COSHH regulations 2002. For qualitative testing -
3M

™

FT10 and FT30 Fit Test Kits are available.

Fit Check Procedure

For Valved Respirators:

a) Cover the front of the respirator with both

hands, being careful not to disturb the
position of the respirator.

b) Inhale sharply. A negative pressure should be felt inside the respirator. If air leaks around

the nose, readjust the noseclip as described in step 4 to eliminate leakage. Repeat the
above fit check. If air leaks at the respirator edges, work the straps back along the sides
of the head to eliminate leakage. Retest the seal. Repeat the procedure until the respirator
fits properly.

For Unvalved Respirators:

a) Cover the front of the respirator with both

hands, being careful not to disturb the
position of the respirator.

b) Exhale sharply. A positive pressure should

be felt inside the respirator. If air leaks around the nose, readjust the noseclip as described
in step 4 to eliminate leakage. Repeat the above fit check. If air leaks at the respirator
edges, work the straps back along the sides of the head to eliminate leakage. Retest the
seal. Repeat the procedure until the respirator fits properly.

If you cannot achieve a proper fit, do not enter the contaminated area.
See your supervisor.

Note:

Do not use with beards or other facial hair that may inhibit contact between the

face and the edge of the respirator.

4

4

5

5

CH8300FP V2

"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.

Was this manual helpful?

Helpful for 3 of 3 readers

About this manual

Brand
3M
Model
8310
Document type
Manual
Language(s)
English
Pages
1
File size
2.7 MB
Format
PDF

Ask a question

Up to 3 photos. Max 5 MB each. Formats: JPG, JPEG, PNG, WebP.