IES-5000/5005/6000 Support Notes 1 INDEX Application Notes ............................................................................................................................ 2 Triple play Application (with VLC Line Card) .............................................................. 2 Trip...
Page 3 - Application Notes; Triple play Application (with VLC Line Card); solving technical issues or a common standard.; Triple Play
IES-5000/5005/6000 Support Notes 2 Application Notes Triple play Application (with VLC Line Card) The triple play service is a marketing term for the provisioning of two broadband services, high-speed Internet access and television, and one narrowband service, telephone, over a single broadband conn...
Page 4 - Triple Play scenario topology
IES-5000/5005/6000 Support Notes 3 Triple Play scenario topology All contents copyright (c) 2008 ZyXEL Communications Corporation.
Page 5 - Hardware connections:
IES-5000/5005/6000 Support Notes 4 Hardware connections: P-870H-51 1. DSL: Connect the DSL jack to the VLC1348G-51 card on IES-5000. 2. Ethernet: Connect the clients to the Ethernet jacks: (1).IP Phone to the Ethernet 1 (2).IP STB to the Ethernet 2 (3).PC to the Ethernet 3 IES-5000M (Main Chassis) 1...
Page 7 - Press the; RESET; LED is
IES-5000/5005/6000 Support Notes 6 Configure the P-870H-51: In this scenario, we will use the CPE P-870H-51 with factory-default setting. How to set the P-870H-51 to factory-default? Press the RESET button on the back-end plane of the housing (you can see it in the following picture). Keep it presse...
Page 9 - Load; to open the page shown below:; Enable; check-box to enable the VDSL port1, click; Apply; to save the settings
IES-5000/5005/6000 Support Notes 8 2. Configure the VLC1348G-51. a. Click Port > VDSL . b. Choose slot 3 and port 1, and click Load to open the page shown below: c. Select the Enable check-box to enable the VDSL port1, click Apply to save the settings . All contents copyright (c) 2008 ZyXEL Commu...
Page 10 - the; Setup; to open the page relevant for sub-step
IES-5000/5005/6000 Support Notes 9 d. Click the Setup button in sub-step (1) of the VLAN to open the page relevant for sub-step (2) & (3): Sub-step (1): Open VLAN setup page. Sub-step (2): Join VLAN 100 to VDSL port 1. All contents copyright (c) 2008 ZyXEL Communications Corporation.
Page 12 - for the VDSL; to save the
IES-5000/5005/6000 Support Notes 11 Sub-step (5): Set the default PVID/Priority for the VDSL Port1 , click Apply to save the changes. All contents copyright (c) 2008 ZyXEL Communications Corporation.
Page 15 - port of MSC1000G, and call the Windows; Telnet
IES-5000/5005/6000 Support Notes 14 4. Use ACL rule to replace the VID / Priority for the PPPoE packets. [Note]: So far ACL-rule feature does not support WEB-GUI, we use the CLI method to configure it. a. Login : Connect your PC to the out-of-band MGMT port of MSC1000G, and call the Windows MS-DOS, ...
Page 18 - As in the; b. Set VDSL port 3-1 to join the MVR VLAN; group range
IES-5000/5005/6000 Support Notes 17 5. Use MVR to configure the IPTV setting on MSC1000G. a. Login : As in the step 4 , use Telnet to login. b. Set VDSL port 3-1 to join the MVR VLAN 700 . c. Set multicast group range for MVR VLAN 700 //Since we are using 239.255.255.2 as the multicast group IP in t...
Page 21 - button to save all your settings to NVRAM.
IES-5000/5005/6000 Support Notes 20 7. Save configuration for the IPDSLAM. (1). Open Config Save , then click the Save button to save all your settings to NVRAM. (2). If setting is successful, result is as below. All contents copyright (c) 2008 ZyXEL Communications Corporation.
Page 23 - , after enter the VLAN setting page, and then; Static VLAN; VLAN
IES-5000/5005/6000 Support Notes 22 2. Configure VLANs. a. Click Advanced Application > VLAN , after enter the VLAN setting page, and then choose the Static VLAN link. b. Create VLAN 100 / 500 / 700 for PPPoE / VoIP / IPTV respectively. [Note:] Don’t forget to click the Add button at the bottom o...
Page 27 - PVID; for the relative ports in this scenario.; Advance Application; Don’t forget to click Apply to save the settings.
IES-5000/5005/6000 Support Notes 26 c. Set the default PVID for the relative ports in this scenario. (1). Click Advance Application > VLAN , then choose the VLAN Port Setting (2).Set port 1 / 5 / 7’s PVID as 100 / 500 / 700 as below: Don’t forget to click Apply to save the settings. All contents ...
Page 28 - value for the respective ports in this scenario.; Basic Setting; to call the page below.; at bottom to save the settings.
IES-5000/5005/6000 Support Notes 27 d. Set the default 802.1p Priority value for the respective ports in this scenario. (1). Click Basic Setting > Port Setup to call the page below. (2). Click Apply at bottom to save the settings. All contents copyright (c) 2008 ZyXEL Communications Corporation.
Page 29 - in Save Configuration.; Save; button on the top of the page.
IES-5000/5005/6000 Support Notes 28 e. Save all the settings for the ES-2024A. (1). Click Management > Maintenance , then choose the Config 1 in Save Configuration. (2). Or you can choose the Save button on the top of the page. If saving was successful, you would see result shown below. All conte...
Page 30 - easily adapt this application for a triple-play service network.; Setting up Multiple PVCs; CPE; Video Server; Internet Access
IES-5000/5005/6000 Support Notes 29 Triple play Application (with ALC/SLC Line Card) On the IES-5000, you can use different channels (also known as Permanent Virtual Circuits or PVCs) for different services. Define channels on each DSL port for different services and assign each channel a priority, ...
Page 34 - Select the; Tx Tagging; option to enable egress tagging on port 10.
IES-5000/5005/6000 Support Notes 33 Create a VLAN with VID of 20. Assign ports 2 and 10 to be members of VLAN20. Select the Tx Tagging option to enable egress tagging on port 10. All contents copyright (c) 2008 ZyXEL Communications Corporation.
Page 36 - types arrive at the same time.
IES-5000/5005/6000 Support Notes 35 After the configuration on the devices are complete, video traffic will go through the 0/33 channel and the data traffic will go through the 0/34 channel. Since the 0/33 channel has a higher priority, video traffic will get processed and sent first if both traffic...
Page 37 - VDSL2 to ADSL2+ Fallback; that can be used on the port connected to an ADSL2+ CPE.; IES
IES-5000/5005/6000 Support Notes 36 VDSL2 to ADSL2+ Fallback The VLC1348G-51 can automatically use ADSL2+ for connections where VDSL2 training fails. This allows a longer connection distance. You can also specify ADSL2+ as the only protocol that can be used on the port connected to an ADSL2+ CPE. P ...
Page 38 - and then type “telnet; OK; c. After entering the password you will see the main menu.
IES-5000/5005/6000 Support Notes 37 Configure the P-660H-61 1. Telnet into the P-660H-61 a. In Windows, click Start (usually in the bottom left corner), Run and then type “telnet 192.168.1.1” (the default IP address) and click OK . b. Enter “1234” in the Password field. c. After entering the passwor...
Page 40 - Remote Node Setup; in the; Main Menu; to open; Menu 11 – Remote Node Setup; to configure the remote node of
IES-5000/5005/6000 Support Notes 39 3. Remote Node Setup a. Enter 11 in the Main Menu to open Menu 11 – Remote Node Setup . b. Enter 1 to configure the remote node of MyISP (ISP, SUA) . All contents copyright (c) 2008 ZyXEL Communications Corporation.
Page 42 - Menu 11.6 – Remote Node ATM Layer Options; ENTER; to confirm your changes.
IES-5000/5005/6000 Support Notes 41 j. Menu 11.6 – Remote Node ATM Layer Options appears. k. Specify VPI and VCI. In this case, we type 8 in the VPI # field and 35 in the VCI # field. l. Press ENTER to confirm your changes. All contents copyright (c) 2008 ZyXEL Communications Corporation.
Page 47 - on the navigation panel.; button to save your configuration to nonvolatile memory.
IES-5000/5005/6000 Support Notes 46 4. Config save a. Click Config Save on the navigation panel. b. Click the Save button to save your configuration to nonvolatile memory. All contents copyright (c) 2008 ZyXEL Communications Corporation.
Page 51 - and thus degrades their performance as well.; line length so that the PSD at the receiving end is the same.; PSD
IES-5000/5005/6000 Support Notes 50 Upstream Power Back-Off (UPBO) What is UPBO? Upstream Power back-of (UPBO) helps to run services over loops with different length co-located in the same cable binder (“mixed length” deployments), especially in FEXT-dominated noise environment. Strong FEXT generate...
Page 52 - Modes of UPBO; Standards should specify the recommended modes.; Protection of the long loop; NEG: Protects actually only one loop (one dedicated service); Equal maximum degradation for all loops
IES-5000/5005/6000 Support Notes 51 The followings are general conclusions for applying UPBO in real network. • Non-FEXT dominated environment: Do not apply UPBO! It only causes SNR reduction in short loops with no SNR improvement in long loops. • FEXT-dominated environment: Apply UPBO for all loops...
Page 53 - Methods of UPBO
IES-5000/5005/6000 Support Notes 52 3. Improved performance of short loops The goal of this mode is to maximize the performance of short loops keeping performance degradation of the Long loops limited. NEG: Can be implemented for only one short loop. With more than one short loop performance degrada...
Page 54 - Operator detects failure: diagnose and find out root causes
IES-5000/5005/6000 Support Notes 53 802.1ag CFM What is CFM? IEEE 802.1ag Connectivity Fault Management (CFM) allows service providers to manage each customer service instance individually. A customer service instance, or Ethernet Virtual Connection (EVC),is the service that is sold to a customer an...
Page 55 - CFM Terms; MD Levels
IES-5000/5005/6000 Support Notes 54 Often there are three different organizations involved in a Metro Ethernet service: customers, service providers, and operators. Customers purchase Ethernet service from service providers. Service providers may use their own networks, or the networks of other oper...
Page 57 - WEB GUI Introduction; purpose of identification.
IES-5000/5005/6000 Support Notes 56 WEB GUI Introduction 1. CFM MD Screen CFM Enable: Select or deselect the check box and click Apply to turn the CFM feature on or off. MD Name: Type a name (up to 31 printable ACSII characters) for this MD. This is for the purpose of identification. Level: Type a l...
Page 60 - Diagnosis; Select an MA name under the selected MD.; MEPID; and enter a; MAC; and enter a remote MEP port’s MAC address.
IES-5000/5005/6000 Support Notes 59 4. Loopback Diagnosis MD: Select an MD name. MA: Select an MA name under the selected MD. MEPID: Select an MEP ID to specify which MEP port on the device initiates the test. Target: Specify the destination of the link you are checking. You can select MEPID and ent...
Page 61 - CLI Command Introduction; MSC1000G> switch cfm enable
IES-5000/5005/6000 Support Notes 60 CLI Command Introduction • Enable CFM MSC1000G> switch cfm enable • Disable CFM MSC1000G>swtichcfm disable • Create a MD MSC1000G> switch cfmmd set <md-name><level> • Delete a MD MSC1000G> switch cfmmd delete <md-name> • Create a MA M...
Page 63 - Setting up different DSL port speeds to different subscribers; apply the profile to one or more subscriber ports.; xDSL; Internet
IES-5000/5005/6000 Support Notes 62 Setting up different DSL port speeds to different subscribers An ISP may want to configure a different line speeds for each DSL port. This can be easily and efficiently done in the ZyXEL IES-5000 using profiles. You can configure line profiles with different param...
Page 64 - Profile Assignment; of port 1 to ports 2 to 24.
IES-5000/5005/6000 Support Notes 63 Similarly, configure a profile to allow a high line speed. Enter a descriptive name for the profile (for example, “Profile_HighSpeed”) and set the maximum upstream and downstream rates (for example, 1280Kbps and 24992Kbps). Configuration example using the CLI: a.)...
Page 67 - talk to or hear from stations that are not in the same VLAN groups.; Setting up a VLAN; modem
IES-5000/5005/6000 Support Notes 66 Configuring 802.1Q VLAN A VLAN (Virtual Area Network) allows a physical network to be partitioned into multiple logical networks. Stations on a logical network belong to one group called VLAN group. A station can belong to more than one group. The stations on the ...
Page 70 - Authorized; TGE1> sys sw dot1x enable
IES-5000/5005/6000 Support Notes 69 Station/ Application server Authentication Server (RADIUS) Authorized Unauthorized X SHDSL/ADSL modem SHDSL/ADSL modem IES-5000(SLC/ALC) (Authenticator) PC 1 (Supplicant) PC 2 (Supplicant) Port x Port y Setting up 802.1x Setting up 802.1x To set up an 802.1x infra...
Page 72 - Open the; Local Area connection Properties; screen and click the; Authentication; and select; EAP type
IES-5000/5005/6000 Support Notes 71 3. Supplicant Setup: Windows XP You can use any supplicant/client software (such as MeetingHouse Aegis client, Funk Odyssey client and Microsoft 802.1x client). In this example, we will use take Microsoft 802.1x client software. 3.1 802.1x/MD5-challenge setup Open...
Page 74 - access is not allowed through the DSL port on the CPE.; Syslog Server Application; (such as Syslodd in Unix and Kiwi Syslog Daemon (
IES-5000/5005/6000 Support Notes All contents copyright (c) 2008 ZyXEL Communications Corporation. 73 Once you are authenticated successfully, you can access the network. Otherwise, network access is not allowed through the DSL port on the CPE. 4. Prestige 660R-61 Settings Please refer to the proced...
Page 75 - Syslog server; Network; rom the web site and double-click
IES-5000/5005/6000 Support Notes ADSL/SHDSL modem Syslog server Uplink Network IES-5000 ALC-1248G SLC-1248G Setting up a Syslog server In this section, we will show you how to configure the IES-5000 and Kiwi Syslog . Installing and Running Kiwi’s Syslog Server rom the web site and double-click serve...
Page 76 - Start
IES-5000/5005/6000 Support Notes 75 After the installation process is complete, start the daemon from the Start menu. A screen displays as shown. In this example, assume that the syslog server’s IP address is 192.168.1.77. 2. IES-5000 settings logs and then save the settings. CI command: TGE1> sy...
Page 77 - Ring Topology Application; Setting up a Ring Environment; configuration steps in detail.; Activating Spanning Tree protocol on Ethernet Ports; gateway. However, to prevent network loops in a ring topology; switch; PC; PC; Uplink1
IES-5000/5005/6000 Support Notes All contents copyright (c) 2008 ZyXEL Communications Corporation. Ring Topology Application 76 A ring topology provides network redundancy. This means that when a link is down, the entire network can still be up as traffic is forwarded through another route or , you ...
Page 78 - Activating Spanning Tree protocol; Switch Setup; Activating Spanning Tree protocol on Ethernet ports; Port Setup
IES-5000/5005/6000 Support Notes 77 ports 1 and 2. The following shows the CLI commands. CI command: TGE1> sys sw rstp enable TGE1> sys sw rstp port enable 1 TGE1> sys sw rstp port enable 2 2. Setup IES-2000 2.1 Activating Spanning Tree protocol This section shows how to enable STP on the I...
Page 79 - Click; Uplink2; to configure this port.; Select; Rapid Spanning Tree Protocol; to enable it on the port.
IES-5000/5005/6000 Support Notes 78 Click Uplink2 to configure this port. Select Rapid Spanning Tree Protocol to enable it on the port. All contents copyright (c) 2008 ZyXEL Communications Corporation.
Page 81 - Activating Spanning Tree protocol; This section shows you how to enable STP on the switch.; Advanced Application; in the navigation panel. The main; Spanning Tree Protocol Status; screen; Configuration; to configure spanning tree protocol settings.; Active
IES-5000/5005/6000 Support Notes 80 3. ES-4024 Settings 3.1 Activating Spanning Tree protocol This section shows you how to enable STP on the switch. Log into the web configurator on the ES-4024 and click Advanced Application > Spanning Tree Protocol in the navigation panel. The main Spanning Tre...
Page 82 - port 2 becomes; BLOCKING; Check the state of port 2 on the ES-4024. It has become; FORWARDING
IES-5000/5005/6000 Support Notes 81 ports 1 and 2. 4. Status Results After you connect the uplink port 1 on IES-2000 to port 2 on the ES-4024, the state of port 2 becomes BLOCKING . To test the RSTP/STP mechanism, disconnect the Ethernet cable between uplink port 1 on the IES-5000 and port 1 on the ...
Page 83 - IGMP Snooping/IGMP Filtering Application; Video; Video Client; IGMP
IES-5000/5005/6000 Support Notes 82 IGMP Snooping/IGMP Filtering Application Without IGMP snooping, multicast traffic is treated in the same manner as broadcast traffic, that is, it is forwarded to all ports. With IGMP snooping, multicast traffic of a group is only forwarded to ports that have membe...
Page 85 - Limiting Internet access to users on specific DSL ports; Port 3
IES-5000/5005/6000 Support Notes 84 Limiting Internet access to users on specific DSL ports Some ISPs may want to limit the number of computers behind certain DSL ports to access the Internet or allow computers with specific MAC addresses to access the Internet. These tasks can be easily done with t...
Page 86 - Configuring Port Security; logged in for Internet access on port 3, any user will be blocked.; DHCP Relay Option 82 Application; function. The following figure shows a network example.
IES-5000/5005/6000 Support Notes 85 will not be able to access the Internet on port 3. Save the settings to make the changes take effect. CI command: TGE1> lcman port macfilter enable 7-3 TGE1> lcman port macfilter set 7-3 00:a0:c5:12:34:56 TGE1> lcman port macfilter set 7-3 00:a0:c5:77:88:...
Page 89 - the password is “incognito”.
IES-5000/5005/6000 Support Notes 88 Enter the login user name and password. The default user name is “administrator” and the password is “incognito”. All contents copyright (c) 2008 ZyXEL Communications Corporation.
Page 90 - A screen displays as shown. Make sure that the status of your DHCP is; online; click; Wizards; Enter a name and description for the new rule.
IES-5000/5005/6000 Support Notes 89 A screen displays as shown. Make sure that the status of your DHCP is online . Then click Wizards > Rule Wizard in the tool bar. Enter a name and description for the new rule. All contents copyright (c) 2008 ZyXEL Communications Corporation.
Page 92 - DHCP Option; Keywords; Sub-option field and select the Binary data type.
IES-5000/5005/6000 Support Notes 91 Select DHCP Option in the Keywords field. A configuration screen displays. Set the fields in the screen as shown. Select 82 Relay Agent Information under the Option number field. Enter 1 in the Sub-option field and select the Binary data type. For port 25, VLAN 1,...
Page 94 - In the next wizard screen, click Next to continue.
IES-5000/5005/6000 Support Notes 93 In the next wizard screen, click Next to continue. In next screen, you may specify a DHCP template (with the gateway and DNS settings) to use. Here we will create a new template. All contents copyright (c) 2008 ZyXEL Communications Corporation.
Page 96 - Click Finish to complete the wizard setup.
IES-5000/5005/6000 Support Notes 95 In the next screen, you may choose whether to apply automatic DDNS service on the DHCP server or not. Click Finish to complete the wizard setup. All contents copyright (c) 2008 ZyXEL Communications Corporation.
Page 97 - from the DHCP server once the computer is connected to the network.; Packet Filtering
IES-5000/5005/6000 Support Notes 96 After the configuration, your computer should obtain an IP address of 192.168.1.201 from the DHCP server once the computer is connected to the network. Packet Filtering The packet filtering feature on the IES-5000 allows ISPs to block certain packet types (such as...
Page 98 - Setting up Packet Filtering; Client 2
IES-5000/5005/6000 Support Notes All contents copyright (c) 2008 ZyXEL Communications Corporation. 97 Setting up Packet Filtering u how to configure the IES-5000 to block NETBIOS . IES-5000 settings (ALC-1248G/SLC 1248G) ype the following commands to enable packet filtering on the specific slot-port...