Page 4 - READ AND SAVE THESE INSTRUCTIONS; fe
www.zephyronline.com IMPORTANT SAFETY INSTRUCTIONS FOR RESIDENTIAL USE ONLY READ AND SAVE THESE INSTRUCTIONS PLEASE READ ENTIRE INSTRUCTIONS BEFORE PROCEEDING. IMPORTANT : Save these Instructions for the Local Electrical Inspectors use. INSTALLER : Please leave these Instructions with this unit for ...
Page 7 - Support Frame; TYPE
List of Ma terials Decorative Mesh Filters Control Blower Housing Light Bulbs Range Hood Body Duct Covers Support Frame Assembly TYPE DESCRIPTION N° A M4 1 + 1 B 1/8" x 1/4" 28 C 1/4" x 2-3/4" 4 D M4 x 9/16" 4 Duct Cover Ceiling Bracket - 7 -
Page 9 - front of hood
Hood Specifi ca tions front of hood side of hood top of hood - 9 -
Page 10 - For external and in-line blower preparation
www.zephyronline.com Installa tion - In ternal Blo w e r The following instructions are for installing the internal blower. CAUTION: To reduce the risk of fi re and electric shock, install this range- hood only with internal blower models MT-020 provided with the kit cod CBI-600A. For external and i...
Page 11 - Attach the 6 pin male molex connector from
Installa tion - In ternal Blo w e r 6. Attach the 6 pin male molex connector from blower wire to the 6 pin female molex con-nector located inside the blower housing. See Fig.6 7. Install the motor and bracket, inside the motor housing, completing the installation using the other screws (6 type B) th...
Page 12 - For internal blower instructions please turn to page 10.; Note; : Carry out the power supplly connection
www.zephyronline.com Installa tion - Ex ternal & In-Line Blo w er P repar a tion The following instructions are for preparing the hood for use with an ex- ternal or in-line blowers models CBE-1000 or PBN-1000A.CAUTION: To reduce the risk of fi re and electric shock, install this rangehood only w...
Page 13 - Reinstall the cover on the motor housing by; See manual included with external and in-
Installa tion - Ex ternal & In-Line Blo w er P repar a tion Note1 : A cable lock (not included) may be re- quired by local codes. Please review local co-des for more information. 6. Reinstall the cover on the motor housing by following the instructions from step 2 in re-verse order. 7. Attach 6 ...
Page 14 - WARNING FIRE HAZARD; Use single wall rigid Metal ductwork only.; Installa
www.zephyronline.com WARNING FIRE HAZARD NEVER exhaust air or terminate duct work into spaces between walls, crawl spaces, ceiling, attics or garages. All exhaust must be ducted to the outside, unless using the recirculating op-tion. Use single wall rigid Metal ductwork only. Fasten all connections ...
Page 15 - MOUNTING HEIGHTS; Remove support frame assembly
Installa tion - Moun ting the R ange Hood MOUNTING HEIGHTS The range hood must be installed at a minimum height of 24 inches (61 cm) from the cooking surface. If a connecting duct work composed of two parts is used, the upper part must be placed outside the lower part. Do not connect the range hood ...
Page 16 - Secure the top support frame to
www.zephyronline.com Installa tion - Moun ting the R ange Hood 2. Secure the top support frame to the duct cover ceiling bracket by using the (4 type B) screws. Fig. 10 3. Position hole template on the ceiling paying attention that the arrow is po-sitioned on the same side as the range hood controls...
Page 17 - POWER SUPPLY CONNECTION
5. Insert the bottom support frame into the top support frame. Fig.12 Adjust height according to your in- stallation and secure the support frames together using (2 type B) screws per extension arm (8 total). Fig.13 6. Insert the motor housing into the support frame assembly and secure it using (8 t...
Page 18 - GENERAL
www.zephyronline.com Installa tion - P o w er Supply C onnec tion GENERAL • Carefully read the following important information regarding installationsafety and maintenance. Keep this information booklet accessible for furtherconsultations. POWER SUPPLY CONNECTION For connection to the power supply r...
Page 19 - suring that the tab on the lid is within the enclosure.
Installa tion - P o w er Supply C onnec tion 11. Replace the lid by following the instructions from step 9 in reverse order, en- suring that the tab on the lid is within the enclosure. 12. Having connected the equipment to the power supply, you can now continue with the ceiling mounting instructions...
Page 20 - MAINTENANCE
www.zephyronline.com Main tencanc e MAINTENANCE • It is recommended to operate the appliance prior to cooking. It is recommended to leave the appliance in operation for 5 minutes after cooking is completed in order to completely eliminate cooking vapors and odors. The proper function of the range ho...
Page 21 - DESCRIPTION; OPTIONAL ACCESSORIES; Recirculating Kit
List of P a rts and A cc essories DESCRIPTION HOOD PART# REPLACEMENT PARTS Light Bulb GU4, 20W (each) ASL Z0B0030 OPTIONAL ACCESSORIES Recirculating Kit ASL ZRC-00SL Replacement Charcoal Filters ASL Z0F-00AC Duct Cover Extension (12” ceiling) ASL Z1C-00SL To order parts, visit us online at http://st...