Page 2 - IMPORTANT
FCC INFORMATION (U.S.A.) 1. IMPORTANT NOTICE: DO NOT MODIFY THIS UNIT! This product, when installed as indicated in the instructions contained in this manual, meets FCC requirements. Modifications not expressly approved by Yamaha may void your authority, granted by the FCC, to use the product. 2. IM...
Page 3 - Important Information; Please read before operating the DA824; Warnings
i DA824—Owner’s Manual Important Information Please read before operating the DA824 Warnings • Do not subject the DA824 to extreme temperatures, humidity, direct sunlight, or dust, which could be a potential fire or electrical shock hazard. • Do not allow water to enter the DA824 or allow it to beco...
Page 5 - Trademarks
iii DA824—Owner’s Manual Package Contents The DA824 package should contain the following items. Contact your Yamaha dealer if anything is missing. • DA824 DA Converter • Power cord • This manual Trademarks ADAT MultiChannel Optical Digital Interface is a trademark of Alesis Corporation. Tascam Digit...
Page 6 - iv; Contents
iv Contents DA824—Owner’s Manual Contents 1 Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 Welcome . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1Installation . . . . . . . . . . . . . . . . . . ....
Page 7 - Introduction; Welcome; Installation
Introduction 1 DA824—Owner’s Manual 1 Introduction Welcome Thank you for choosing the Yamaha DA824 DA Converter. The DA824 is a high-performance 8-channel digital-to-analog converter, with 24-bit linear digital-to-analog converters and 128-times oversampling providing a typical dynamic range of 110 ...
Page 8 - Front Panel; LOCK indicator; POWER switch
2 Chapter 2—Touring the DA824 DA824—Owner’s Manual 2 Touring the DA824 Front Panel A PEAK, NOMINAL & SIGNAL indicators These indicators show the signal level of each channel. PEAK —This indicator lights up when the signal level is 3 dB below full-scale output. NOMINAL —This indicator lights up w...
Page 9 - Rear Panel; COM port
Rear Panel 3 DA824—Owner’s Manual Rear Panel A COM port This port is for updating the DA824’s internal firmware and is not used in normal oper-ation. B WORD CLOCK THRU connector This BNC connector transmits the wordclock signal received at the WORD CLOCK IN. C WORD CLOCK 75 Ω ON/OFF switch This swit...
Page 10 - About Digital I/O Cards
4 Chapter 3—Digital I/O Cards DA824—Owner’s Manual 3 Digital I/O Cards About Digital I/O Cards For digital input, the DA824 uses optional mini YGDAI (Yamaha General Digital Audio Interface) cards, which are available in all the popular digital audio interconnect for-mats, including AES/EBU, ADAT, an...
Page 12 - Hookup Examples; Basic AES/EBU Connection
6 Chapter 4—Hookup Examples DA824—Owner’s Manual 4 Hookup Examples In the following hookup examples, the “Digital Audio Device” could be any device with a compatible AES/EBU or ADAT interface, including the following Yamaha products with the necessary I/O cards installed: DME32 Digital Mixing Engine...
Page 13 - AES/EBU Connection with Splitter Cable
AES/EBU Connection with Splitter Cable 7 DA824—Owner’s Manual AES/EBU Connection with Splitter Cable This example shows how both an AD824 and DA824 can be connected to a digital audio device with a single AES/EBU interface by using MY8-AE I/O cards and a custom AES/EBU splitter cable. Pin wiring det...
Page 14 - Wordclocks; About Wordclocks
8 Chapter 5—Wordclocks DA824—Owner’s Manual 5 Wordclocks About Wordclocks For correct operation and digital-to-analog processing, it is essential that the DA824 is wordclock locked to the digital audio device transmitting the digital audio signals. Nor-mally, the DA824 locks to a wordclock signal de...
Page 15 - Wordclock Termination; Wordclock Distribution Box
Wordclock Termination 9 DA824—Owner’s Manual Wordclock Termination For correct and reliable operation, wordclock signals distributed via BNC cables must be terminated correctly. Termination is typically applied at the last device, although it depends on the distribution method being used. The DA824’...
Page 16 - Appendix; Specifications
10 Appendix DA824—Owner’s Manual Appendix Specifications Sampling rate MY8-AE, MY8-TD 39.69–50.88 kHz MY8-AT 41.013–50.88 kHz DA conversion resolution 24-bit linear, 128-times oversampling Frequency response –3, +1 dB, 20 Hz–20 kHz Dynamic Range 1 1. Measured with a 6 dB/octave filter at 12.7 kHz; e...
Page 17 - Analog Output
Specifications 11 DA824—Owner’s Manual Analog Output Digital I/O Connection GAIN SW Actual Source Impedance For Use with Nominal Output Level Connector Nominal Max. before clip OUTPUT 1–8 1 1. 24-bit 128-times oversampling D/A converters. +24 dB 150 Ω lines 600 Ω lines +10 dB (2.45 V) +24 dB (12.28 ...
Page 18 - Dimensions
12 Appendix DA824—Owner’s Manual Dimensions Specifications and external appearance subject to change without notice. For European Model Purchaser/User Information specified in EN55103-1 and EN55103-2.Inrush Current: 10AConformed Environment: E1, E2, E3 and E4 67.5 67.5 345 430 13 88 H: 97.5 30 30 48...