Page 3 - Table of Contents
iii 1. Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 2. Important Safety Information . . . . . . . . . . . . . . . . . . 2 Warnings and Cautions . . . . . . . . . . . . . . . . . . . . . . . . 2 3. XPower 150 Inverter Features . . . . . . . . . . . . . . . . . . 5 ...
Page 5 - Introduction; Instructions for connecting the inverter (page 7)
1 1 Introduction Thank you for purchasing the XPower Inverter 150. The XPower 150 is part of a family of advanced high-performance power inverters from Xantrex, the leader in high frequency inverter design. Connected to the 12 volt outlet in your vehicle, the XPower 150 efficiently and reliably powe...
Page 6 - Important Safety Information; Warning; statements identify; Caution; statements identify conditions or practices that; Warnings and Cautions; WARNING: Shock hazard
2 2 Important Safety Information If the XPower 150 is connected or used incorrectly, hazardous conditions may be created. Read and save this safety information, and pay special attention to all Warning and Caution statements in the guide and on the inverter itself. Warnings and Cautions are indicate...
Page 9 - XPower 150 Inverter Features; This section describes the main features of the XPower 150.; Figure 1; AC Panel on the XPower 150 (European Outlet); AC Outlet; An AC outlet is located on one end of the; Æ Ø
5 3 XPower 150 Inverter Features This section describes the main features of the XPower 150. Figure 1 shows the inverter’s AC panel. Figure 1 AC Panel on the XPower 150 (European Outlet) ¨ AC Outlet An AC outlet is located on one end of the XPower 150. It allows you to plug in a 230 volt AC load wit...
Page 10 - Power Light; The green; light is on all the time; Fault Light; The red; Audible Alarm; An audible alarm warns you of a high-; AC Outlets; Figure 2; European AC; Figure 3; British AC; Figure 4; Australian and New Zealand AC
6 Æ Power Light The green PWR light is on all the time when the On/Standby switch is on. Ø Fault Light The red light indicates that the inverter has shut down because of low or high battery voltage, AC overload, or excessively high temperatures. Audible Alarm An audible alarm warns you of a high- te...
Page 11 - Connecting the XPower 150; Choosing a Location; Dry; Connecting
7 4 Connecting the XPower 150 Choosing a Location For best performance, choose a location that is: • Dry Do not expose the inverter to water drip or spray. • Cool Operate the inverter in ambient temperatures between 0° C and 40° C (32° F and 100° F). Keep it away from heating vents and direct sunlig...
Page 12 - Operating Statuses; Normal Operation; Low Battery Voltage Alarm and Shutdown
8 5 Operating the XPower 150 Operating Statuses This section describes normal operation as well as problems that could occur when you use the inverter. If you have a problem, see “Troubleshooting” on page 12. • Normal Operation When you connect the inverter to your vehicle’s 12 volt outlet and turn ...
Page 13 - AC Overload Shutdown; Note: High startup surge requirements; High Temperature Shutdown
9 that occurs when the engine starts may trigger a low voltage shutdown. • AC Overload Shutdown If you connect an AC load that is rated higher than 150 watts or 0.65 amps or that draws excessive surge power, the XPower 150 shuts down. The PWR light stays on, and the light comes on to indicate that t...
Page 14 - Interference With Electronic Equipment; Buzzing Sound; Some inexpensive stereo systems and; Television Interference; The XPower 150 is shielded to
10 Interference With Electronic Equipment Most AC loads operate with the XPower 150 as they would with household AC power with the following exceptions. Buzzing Sound Some inexpensive stereo systems and “boom boxes” have inadequate internal power supply filtering and buzz slightly when powered by th...
Page 15 - Battery Operating Time; To preserve the battery:
11 6 Battery Operating Time The operating time of the XPower 150 depends on the charge level of the battery, the battery capacity, and the amount of power drawn by the particular AC load being used. With a typical vehicle battery and a 150 watt AC load (like a small TV), you can expect two to three ...
Page 16 - Troubleshooting; The AC load will not operate the; An AC load is plugged in or turned on, operates; Symptom; The AC load will not operate. The; Possible cause
12 7 Troubleshooting This section describes problems you could encounter as well as possible causes and various remedies. The AC load will not operate; the light is on. Symptom An AC load is plugged in or turned on, operates for one to ten seconds, and then shuts down. Symptom The AC load will not o...
Page 18 - The AC voltmeter reading is 5 to 15 volts too; Battery operating time is less than expected.; The inverter runs for a while, and then the
14 Measured inverter output voltage is too low. Symptom The AC voltmeter reading is 5 to 15 volts too low. Battery operating time is less than expected. Symptom The inverter runs for a while, and then the light comes on. The inverter is cool or warm to touch. Possible cause Suggested remedy The ligh...
Page 19 - Specifications; Specifications may change without notice.; Electrical
15 8 Specifications Specifications may change without notice. Electrical AC receptacles 1 AC output voltage 230 volts AC ± 5% AC output frequency 50 Hz ± 3 Hz AC output waveform Modified Sine Wave Maximum continuous AC output power 150 watts Maximum AC output surge power 300 watts DC input voltage r...
Page 21 - Limited Warranty; Warranty; What does this warranty cover?; What will Xantrex do?
17 9 Limited Warranty Warranty What does this warranty cover? This Limited Warranty is provided by Xantrex Technology, Inc. ("Xantrex") and covers defects in workmanship and materials in your XPower Inverter 150. This warranty period lasts for twenty-four (24) months from the date of purchas...
Page 22 - How do you get service?; What proof of purchase is required?
18 How do you get service? If your product requires troubleshooting or warranty service, contact your merchant. If you are unable to contact your merchant, or the merchant is unable to provide service, contact Xantrex directly at: Direct returns may be performed according to the Xantrex Return Mater...
Page 23 - What does this warranty not cover?; Disclaimer; Product
19 What does this warranty not cover? This Limited Warranty does not cover normal wear and tear of the product or costs related to the removal, installation, or troubleshooting of the customer's electrical systems. This warranty does not apply to and Xantrex will not be responsible for any defect in...
Page 24 - Exclusions
20 RESTRICTION ANY IMPLIED WARRANTY OR CONDITION OF QUALITY, MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. ANY IMPLIED WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE TO THE EXTENT REQUIRED UNDER APPLICABLE LAW TO APPLY TO THE PRODUCT SHALL BE LIMITED IN DURATION TO THE PERIOD...
Page 25 - Warning: Limitations On Use; Return Material Authorization Policy
21 Warning: Limitations On Use Please refer to your product manual for limitations on uses of the product. SPECIFICALLY, PLEASE NOTE THAT THE XP OWER I NVERTER 150 SHOULD NOT BE USED IN CONNECTION WITH LIFE SUPPORT SYSTEMS OR OTHER MEDICAL EQUIPMENT OR DEVICES. WITHOUT LIMITING THE GENERALITY OF THE...
Page 26 - Return Procedure
22 Return Procedure 1. Package the unit safely, preferably using the original box and packing materials. Please ensure that your product is shipped fully insured in the original packaging or equivalent. This warranty will not apply where the product is damaged due to improper packaging. 2. Include t...
Page 27 - Out of Warranty Service; 0 Other Xantrex Products
23 Out of Warranty Service If the warranty period for your XPower Inverter 150 has expired, if the unit was damaged by misuse or incorrect installation, if other conditions of the warranty have not been met, or if no dated proof of purchase is available, your inverter may be serviced or replaced for...