Westinghouse MA7200 Plus - Manual
Westinghouse MA7200 Plus – Manual, read for free online in PDF format. We hope this helps you resolve any issues you may have. If you have further questions, please contact us through the contact form.
Table of Contents:
- Page 2 – PID Quick Start Guide for Fan and Pump Applications; - Before Starting the Inverter; CAUTION; To avoid damage to the inverter when removing the inverter cover
- Page 3 – - Apply Power to the Drive; Hz; - Set Drive to Run Mode; on; RUN; - Check Fan or Pump Motor Operation
- Page 4 – Danger; two; – Making External Digital Input/Output and Analog Feedback
- Page 5 – TECO – Westinghouse Motor Company; DIGITAL INPUT / OUTPUT terminal connections; if
- Page 6 – ANALOG FEEDBACK terminal connections; devices
- Page 8 – – Setting Minimum Speed in Pump Applications; (NOTE: In the case of a fan application skip this step and go to Step 8); Input Voltage; Entry Accepted; Keypad Steps; Freq Cmd Low Bound
- Page 9 – or 0 – 10 Vdc]; ensure the inverter is in the STOP mode.
- Page 10 – Inverter Capacity; External Input; Step 9; valid
- Page 11 – key
- Page 15 – times; Acceleration
- Page 16 – (NOTE: In the case of a Fan application skip this step and go to Step13)
- Page 17 – PSI
- Page 18 – key 4 times; key to
- Page 21 – – Testing The System; feedback
MA7200
PLUS
INVERTER
SERIES
PID Quick Start Manual
For Fan and Pump Applications
speed
time
1 to 2 HP
Models- MA7200-2001/2-N1 (230V)
&
MA7200-4001/2-N1 (460V)
Rev. 1.3 - May 27
th
2008
"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.
Summary
MA7200 PLUS Inverter 1 to 2 HP PID Fan and Pump Quick Start Manual __________________________________________________________________ ________________________________________________________________ TECO – Westinghouse Motor Company 2 PID Quick Start Guide for Fan and Pump Applications PID is a cont...
MA7200 PLUS Inverter 1 to 2 HP PID Fan and Pump Quick Start Manual __________________________________________________________________ ________________________________________________________________ TECO – Westinghouse Motor Company 3 Step 2 - Apply Power to the Drive • Apply AC power to the Inverte...
MA7200 PLUS Inverter 1 to 2 HP PID Fan and Pump Quick Start Manual __________________________________________________________________ ________________________________________________________________ TECO – Westinghouse Motor Company 4 • Press the RUN key, and check the fan or pump direction of rotat...