Page 2 - PID Quick Start Guide for Fan and Pump Applications; - Before Starting the Inverter; CAUTION; To avoid damage to the inverter when removing the inverter cover
MA7200 PLUS Inverter 1 to 2 HP PID Fan and Pump Quick Start Manual __________________________________________________________________ ________________________________________________________________ TECO – Westinghouse Motor Company 2 PID Quick Start Guide for Fan and Pump Applications PID is a cont...
Page 3 - - Apply Power to the Drive; Hz; - Set Drive to Run Mode; on; RUN; - Check Fan or Pump Motor Operation
MA7200 PLUS Inverter 1 to 2 HP PID Fan and Pump Quick Start Manual __________________________________________________________________ ________________________________________________________________ TECO – Westinghouse Motor Company 3 Step 2 - Apply Power to the Drive • Apply AC power to the Inverte...
Page 4 - Danger; two; – Making External Digital Input/Output and Analog Feedback
MA7200 PLUS Inverter 1 to 2 HP PID Fan and Pump Quick Start Manual __________________________________________________________________ ________________________________________________________________ TECO – Westinghouse Motor Company 4 • Press the RUN key, and check the fan or pump direction of rotat...
Page 5 - TECO – Westinghouse Motor Company; DIGITAL INPUT / OUTPUT terminal connections; if
MA7200 PLUS Inverter 1 to 2 HP PID Fan and Pump Quick Start Manual __________________________________________________________________ ________________________________________________________________ TECO – Westinghouse Motor Company 5 • In this step the external wiring connections will be made for t...
Page 6 - ANALOG FEEDBACK terminal connections; devices
MA7200 PLUS Inverter 1 to 2 HP PID Fan and Pump Quick Start Manual __________________________________________________________________ ________________________________________________________________ TECO – Westinghouse Motor Company 6 ANALOG FEEDBACK terminal connections Fig’s 3a,3b, and 3c, show th...
Page 8 - – Setting Minimum Speed in Pump Applications; (NOTE: In the case of a fan application skip this step and go to Step 8); Input Voltage; Entry Accepted; Keypad Steps; Freq Cmd Low Bound
MA7200 PLUS Inverter 1 to 2 HP PID Fan and Pump Quick Start Manual __________________________________________________________________ ________________________________________________________________ TECO – Westinghouse Motor Company 8 Step 7 – Setting Minimum Speed in Pump Applications (NOTE: In the...
Page 9 - or 0 – 10 Vdc]; ensure the inverter is in the STOP mode.
MA7200 PLUS Inverter 1 to 2 HP PID Fan and Pump Quick Start Manual __________________________________________________________________ ________________________________________________________________ TECO – Westinghouse Motor Company 9 Step 8 – Select PID control (Sn-64), and Feedback input (Sn – 24)...
Page 10 - Inverter Capacity; External Input; Step 9; valid
MA7200 PLUS Inverter 1 to 2 HP PID Fan and Pump Quick Start Manual __________________________________________________________________ ________________________________________________________________ TECO – Westinghouse Motor Company 10 PRGM DRIVE DSPL EDIT ENTER Sn – 01 - key twice Inverter Capacity...
Page 11 - key
MA7200 PLUS Inverter 1 to 2 HP PID Fan and Pump Quick Start Manual __________________________________________________________________ ________________________________________________________________ TECO – Westinghouse Motor Company 11 key 4 times Flashing 1 - Press the 2 - Press the 3 - Press the k...
Page 15 - times; Acceleration
MA7200 PLUS Inverter 1 to 2 HP PID Fan and Pump Quick Start Manual __________________________________________________________________ ________________________________________________________________ TECO – Westinghouse Motor Company 15 Step 11 – S etting parameters acceleration (Bn-01) and decelerat...
Page 16 - (NOTE: In the case of a Fan application skip this step and go to Step13)
MA7200 PLUS Inverter 1 to 2 HP PID Fan and Pump Quick Start Manual __________________________________________________________________ ________________________________________________________________ TECO – Westinghouse Motor Company 16 2 - Press the key EDIT ENTER key to save . 4 - Press the Entry A...
Page 17 - PSI
MA7200 PLUS Inverter 1 to 2 HP PID Fan and Pump Quick Start Manual __________________________________________________________________ ________________________________________________________________ TECO – Westinghouse Motor Company 17 • To further cover the PID Sleep function, the following is an e...
Page 18 - key 4 times; key to
MA7200 PLUS Inverter 1 to 2 HP PID Fan and Pump Quick Start Manual __________________________________________________________________ ________________________________________________________________ TECO – Westinghouse Motor Company 18 PRGM DRIVE DSPL P1-04 key 4 times PID Sleep Function 1 - Press t...
Page 21 - – Testing The System; feedback
MA7200 PLUS Inverter 1 to 2 HP PID Fan and Pump Quick Start Manual __________________________________________________________________ ________________________________________________________________ TECO – Westinghouse Motor Company 21 Step 13 – Testing The System • The system can now be tested for ...