Page 2 - xi
NOTE: For your protection, please note that equipment in this shipment was carefully inspected and packaged by skilled personnel before leaving the factory. Upon acceptance of this shipment, the transportation company assumes full responsibility for its safe delivery. IF SHIPMENT ARRIVES DAMAGED: 1....
Page 4 - FEATURES AND OPERATING CONTROLS - AUTOMATIC BREWERS; Fig. 1 Features & Operating Controls for Single Cup Brewers
FEATURES AND OPERATING CONTROLS - AUTOMATIC BREWERS 2 Fig. 1 Features & Operating Controls for Single Cup Brewers
Page 5 - PRECAUTIONS AND GENERAL INFORMATION; Failure to heed this warning can result in electrical shock.; AGENCY LISTING INFORMATION; Installation
3 PRECAUTIONS AND GENERAL INFORMATION WARNING: ELECTRIC SHOCK HAZARD All servicing requiring access to non-insulated components must be performed by qualified service personnel. Do not open any access panels which require the use of tools. Failure to heed this warning can result in electrical shock....
Page 6 - INSTALLATION; READ THIS CAREFULLY BEFORE STARTING THE INSTALLATION; LEVELING THE UNIT
INSTALLATION READ THIS CAREFULLY BEFORE STARTING THE INSTALLATION Unpack the unit. Inspect all components for completeness and condition. Ensure that all packing materials have been removed from the unit. LEVELING THE UNIT Verify that an adjustable leg is installed at each of the five locations on t...
Page 7 - PLUMBER’S INSTALLATION INSTRUCTIONS; line. Flush water line before connecting to Brewer.
5 INSTALLATION (continued) CAUTION: ELECTRICAL DAMAGE DO NOT plug in or energize this appliance until all Installation Instructions are read and followed. Damage to the Brewer will occur if these instructions are not followed. NOTE: Water supply inlet line must meet certain minimum criteria to insur...
Page 8 - Before connecting to electricity, make sure; Fig. 3 Power Supply Plug
6 WARNING: SHOCK HAZARD Brewer must be properly grounded to prevent possible shock hazard. DO NOT assume a plumbing line will provide such a ground. Electrical shock will cause death or serious injury. IMPORTANT: Supply power must match nameplate for voltage and phase. Connecting to the wrong voltag...
Page 9 - OPERATION; NOT COVERED BY
OPERATION 7 A. START-UP For initial start-up, or if the brewer has not been used for an extended period of time: ♦ Be sure the water supply is properly connected and the water supply valve is turned ON . ♦ Be sure that TANK HEATER SWITCH is OFF before connecting brewer to electric power. ♦ Be sure t...
Page 10 - FOUR BREW OPTIONS; B. PROGRAM BREW VOLUMES; IMPORTANT: Allow for an additional 2 oz to be pushed
Fig. 5 Program Brew Select Keys Table I. FOUR BREW OPTIONS OPERATION (continued) 8 B. PROGRAM BREW VOLUMES ♦ Each BREW SELECT KEY is individually programmable. ♦ Keys may be programmed for pulse brewing to optimize contact times and extraction rates,. ♦ Up to 10 pulses may be programmed. Each pulse ...
Page 11 - OPERATION - BREWING COFFEE; EMPTY; BURN HAZARD
OPERATION - BREWING COFFEE 1. Unlock the pod holder by pulling the LOCKING LEVER fully forward. 2. Pull the BREW TRAY fully forward, then lower tray. NOTE: Normally, the brewer will automatically discard the last pod. If the brewer has not been used for some time, the used pod may need to be removed...
Page 12 - Remove any cup, then remove drip tray and cup grid.
CLEANING INSTRUCTIONS PROCEDURE: Clean Coffee Brewer PRECAUTIONS: Disconnect brewer from electric power. Allow brewer to cool. FREQUENCY: Daily TOOLS: Mild Detergent, Clean Soft Cloth or Sponge Bristle Brush, Bottle Brush 1. Disconnect brewer from electric power. Allow brewer to cool before cleaning...
Page 14 - TROUBLESHOOTING SUGGESTIONS; SYMPTOM
TROUBLESHOOTING SUGGESTIONS 12 SYMPTOM POSSIBLE CAUSE SUGGESTED REMEDY Water won’t heat Tank heater switch OFF Press switch to ON Brewer unplugged or circuit breaker tripped Check power supply cord Check / reset circuit breaker Temperature setpoint too low Set for desired temperature Hi-Limit safety...
Page 15 - SERVICING INSTRUCTIONS
13 SERVICING INSTRUCTIONS CAUTION: SHOCK HAZARD Opening access panels on this brew may expose uninsulated electrical components. Disconnect brewer from electrical power before removing any panel. Trouble shooting instructions, component views and parts lists in this manual are included for general r...
Page 16 - TEMPERATURE ADJUSTMENT; Fig. 7 Checking and Adjusting Brew Temperature; TEM
14 TEMPERATURE ADJUSTMENT Disconnect brewer from electric power. Pull vent tube out of tank lid and insert a thermometer of known accuracy in hole. Reconnect brewer to electrical power. Place empty cup on the cup grid. Energize brewer and allow unit to heat. When READY light glows, read the temperat...
Page 17 - REPLACE HEATING ELEMENT
SERVICING INSTRUCTIONS (continued) 15 IMPORTANT: Before setting assembly into tank, make sure tank lid gasket is properly seated on flange of lid. DO NOT OVER-TIGHTEN . IMPORTANT: When mounting thermostat, be sure to insert sensing bulb to the bottom of the bulb well. Tighten capillary lock nut only...
Page 18 - OFF
SERVICING INSTRUCTIONS (continued) 16 REPLACE SOLENOID Symptom: Brewer will not flow water; or, brewer drips continuously from pod holder or brew nozzle. NOTE: Wrench p/n 86660 is designed to allow easy removal of flare nuts from the water inlet fitting IMPORTANT: Shut-off water to brewer and discon...
Page 19 - CLEAN UPPER POD HOLDER; Upper pod holder can be cleaned in place.; CLEAN LOWER POD HOLDER; Lower pod holder can be cleaned in place. It is not
SERVICING INSTRUCTIONS (continued) 17 CAUTION: SHOCK HAZARD DO NOT pour, spill or splash water onto, into or over any internal component. IMPORTANT: DO NOT use steel wool, sharp objects, or caustic, abrasive or chlorinated cleansers to clean these components. Fig. 11 Upper Pod Holder Fig. 12 Lower P...
Page 20 - REPLACE CONTROLLER; Fig. 11 Controller Wiring Configuration
SERVICING INSTRUCTIONS (continued) 18 IMPORTANT: The two keypad ribbon cables connectors are not polarized and can easily be installed in the wrong position. Be sure to mark the ribbon cable connectors for orientation. REPLACE CONTROLLER Disconnect brewer from electric power. Remove top panel Note l...
Page 21 - PROCEDURE: Delime the Water Tank
SERVICING INSTRUCTIONS (continued) 19 CAUTION: CHEMICAL BURN HAZARD Deliming chemicals may be caustic. Wear appropriate protective gloves and goggles during this procedure. Never siphon deliming chemicals or solutions by mouth. This operation should only be performed by qualified and experienced ser...
Page 22 - EXPLODED VIEW & PARTS LIST; CABINET COMPONENTS
EXPLODED VIEW & PARTS LIST 20 CABINET COMPONENTS
Page 24 - BREW TRAY COMPONENTS
EXPLODED VIEW & PARTS LIST 22 BREW TRAY COMPONENTS
Page 27 - WIRING DIAGRAM
Page 28 - Division of Carrier Commercial Refrigeration; for
PRINTED IN CHINA Bloomfield Industries, Inc. Division of Carrier Commercial Refrigeration In US and Canada Telephone: 775-689-5700 Fax: 888-492-2783 Fax: 800-356-5142 ( ) website: www.wellsbloomfield.com for orders only Bloomfield Industries proudly supports CFESA Commercial Food Equipment Service A...