Page 3 - not provided
TABLE OF CONTENTS Thank You for purchasing this Bloomfield Industries appliance. Proper installation, professional operation and consistent maintenance of this appliance will ensure that it gives you the very best performance and a long, economical service life. This manual contains the information ...
Page 4 - FEATURES AND OPERATING CONTROLS; Fig 1. SS-1 Satellite Brewing System Features & Operating Controls
FEATURES AND OPERATING CONTROLS 2 Fig 1. SS-1 Satellite Brewing System Features & Operating Controls 663 76061 Ow ners M a n ual for 910 2A S ingle Satellite Bre w er
Page 7 - INSTALLATION INSTRUCTIONS; INSTALL LEGS; If water pressure varies greatly, or exceeds 90 psi at any; water hammer; in the incoming line,
5 INSTALLATION INSTRUCTIONS INSTALL LEGS The brewer is provided with adjustable legs. Be sure all four legs are securely screwed into the base of the brewer. LEVEL THE UNIT The adjustable legs allow the brewer to be leveled. Set the brewer in its ultimate operating location and check for level with ...
Page 8 - ON; ELECTRICIAN’S INSTALLATION INSTRUCTIONS; OFF
INSTALLATION INSTRUCTIONS (continued) 6 CAUTION: Electric Shock Hazard Brewer must be properly grounded to a reliable earth ground to prevent possible shock hazard. Do not assume a plumbing line will provide such a ground. Electrical shock may cause serious injury. IMPORTANT: Initial set-up must be ...
Page 9 - OPERATING INSTRUCTIONS; Fig. 5 Control Panel; STOP; Prepare the Brew Basket:; START BREW
7 OPERATING INSTRUCTIONS Fig. 5 Control Panel Fig. 6 Brew Basket IMPORTANT: To avoid overflows, DO NOT start the brew cycle unless an EMPTY satellite is in place under the brew chamber. NOTE: The brew can be cancelled at any time by pressing the STOP switch. NOTE: DO NOT change the VOLUME SELECT swi...
Page 10 - Fig. 7 Water Flow Diagram; HOT WATER FAUCET
OPERATING INSTRUCTIONS (continued) 8 Fig. 7 Water Flow Diagram BREW & BYPASS This brewer is a standard displacement brewer with pour-over option. For 9102A there is no bypass. Water admitted into the hot water tank by the BREW SOLENOID will displace a like amount of heated water through the brew...
Page 11 - CLEANING INSTRUCTIONS
9 CLEANING INSTRUCTIONS CLEANING INSTRUCTIONS PROCEDURE: Clean Coffee Brewer PRECAUTIONS: Turn POWER SWITCH OFF. Allow brewer to cool. FREQUENCY: Daily TOOLS: Mild Detergent, Clean Soft Cloth or Sponge Bristle Brush 1. Turn POWER SWITCH OFF . Allow brewer to cool. 2. Remove satellite. 3. Remove and ...
Page 12 - PROCEDURE: Clean Satellite; Remove the shield cap (large vent) on top of the sight glass.
10 CLEANING INSTRUCTIONS (continued) PROCEDURE: Clean Satellite PRECAUTIONS: Drain Satellite before Cleaning FREQUENCY: Twice Weekly TOOLS: Sight Glass Brush, Sanitizer Soft Clean Cloth, Bucket 1. Remove and drain satellite. 2. Place 1 packet of Sanitizer into 2-1/2 gallons of warm tap water. Pour a...
Page 13 - TROUBLESHOOTING SUGGESTIONS
TROUBLESHOOTING SUGGESTIONS SYMPTOM POSSIBLE CAUSE SUGGESTED REMEDY Will not heat or brew (no lights) Brewer not plugged in or circuit breaker tripped Reconnect brewer to electric power Reset circuit breaker Main power switch off or damaged Check. Turn main power switch on. Replace if needed Will no...
Page 14 - SERVICING INSTRUCTIONS; SHOCK HAZARD; Wrench for Faucet Tubing; ACCESS PANELS
12 SERVICING INSTRUCTIONS CAUTION: SHOCK HAZARD Disconnect brewer from electric power before opening any access panel. Note position of any wires or hoses before removing them from a panel. Wrench for Faucet Tubing ACCESS PANELS TOP PANEL is attached with two screws at the rear and a lip at the fron...
Page 15 - TEMPERATURE ADJUSTMENT; CLOCKWISE
13 CAUTION: SHOCK HAZARD Live electrical circuits are exposed during this procedure. Use care to avoid uninsulated electrical connectors. Adjustments to be performed by qualified technician only. NOTE: 1/8 turn = approx 10ºF (5.5ºC) TEMPERATURE ADJUSTMENT PRECAUTIONS: Disconnect brewer from electric...
Page 16 - BREW TIMER ADJUSTMENT; Press TANK HEATER switch to
SERVICING INSTRUCTIONS (continued) 14 Adjustments to be performed by qualified technician only. NOTE: Brewer is pre-adjusted to deliver 1/2, 1 and/or 1-1/2 gallons of coffee at a water pressure of 50 p.s.i. Use this procedure to adjust the delivered volume to suit local conditions. Adjust only in sm...
Page 17 - Bypass Gauge Set
SERVICING INSTRUCTIONS (continued) 15 CAUTION: SHOCK HAZARD Disconnect brewer from electric power before opening the top panel. The brewer is shipped from the factory pre-set for 25% bypass. This adjustment must never be made unless the brewer is installed on a soft water line, or a change in coffee...
Page 18 - PROCEDURE: Delime the Water Tank; Disconnect brewer from the electrical supply.
CAUTION: CHEMICAL BURN HAZARD Deliming chemicals are caustic. Wear appropriate protective gloves and goggles during this procedure. Never siphon deliming chemicals or solutions by mouth. This operation should only be performed by qualified and ex-perienced service personnel. IMPORTANT: DO NOT spill,...
Page 21 - ELECTRICAL COMPONENTS
EXPLODED VIEW (continued) 19 ELECTRICAL COMPONENTS 663 76061 Ow ner s M a n ual for 9102A Single Sate llite B re w er
Page 22 - CABINET & RELATED COMPONENTS
EXPLODED VIEW ((continued) 20 CABINET & RELATED COMPONENTS 663 76061 Ow ners M a n ual for 910 2A S ingle Satellite Bre w er
Page 23 - SATELLITE ASSEMBLY 9105SS
EXPLODED VIEW (continued) 21 SATELLITE ASSEMBLY 9105SS 663 76061 Ow ner s M a n ual for 9102A Single Sate llite B re w er
Page 24 - SERVICE KITS
22 SERVICE KITS 663 76061 Ow ners M a n ual for 910 2A S ingle Satellite Bre w er FAUCET REPAIR COMPONENTS 82680 Hex Lock Nut 8551-100B 7/16“ Lock Washer 82681 Washer 82556 Faucet Assembly 82573 Handle 82575 Seat Cup 82576 Faucet Repair Kit (Includes Handle, Seat Cup, Spring, Stem, Pin & Bonnet ...
Page 25 - WIRING DIAGRAMS
23 WIRING DIAGRAMS 663 76061 Ow ner s M a n ual for 9102A Single Sate llite B re w er
Page 26 - for
Bloomfield Industries, Inc. Division of Carrier Commercial Refrigeration In US and Canada Telephone: 775-698-5700 Fax: 888-492-2783 Fax: 800-356-5142 ( ) website: www.wellsbloomfield.com for orders only PRINTED IN UNITED STATES OF AMERICA