Page 2 - xi
NOTE: For your protection, please note that equipment in this shipment was carefully inspected and packaged by skilled personnel before leaving the factory. Upon acceptance of this shipment, the transportation company assumes full responsibility for its safe delivery. IF SHIPMENT ARRIVES DAMAGED: 1....
Page 4 - FEATURES AND OPERATING CONTROLS
FEATURES AND OPERATING CONTROLS 2 M62 8 76201 Ow ner s M a n u a l 8781A Tea B re w e r
Page 5 - PRECAUTIONS AND GENERAL INFORMATION; WARNING Electric Shock Hazard; Installation; AGENCY LISTING INFORMATION
PRECAUTIONS AND GENERAL INFORMATION 3 WARNING: Electric Shock Hazard All servicing requiring access to non-insulated components must be performed by qualified service personnel. Do not open any access panels which require the use of tools. Failure to heed this warning can result in electrical shock....
Page 6 - INSTALLATION; READ THIS CAREFULLY BEFORE STARTING THE INSTALLATION; PLUMBER’S INSTALLATION INSTRUCTIONS; line. Flush water line before connecting to Brewer.; Equipment; Water supply inlet line
INSTALLATION 4 READ THIS CAREFULLY BEFORE STARTING THE INSTALLATION Unpack the unit. Inspect all components for completeness and condition. Ensure that all packing materials have been removed from the unit. Verify that the Spray Head Gasket and Spray Disk are properly installed. LEVELING THE UNIT Ve...
Page 7 - water hammer arrester; ELECTRICIAN’S INSTALLATION INSTRUCTIONS; Fig. 2 Water Supply Installation
INSTALLATION (continued) 5 NOTE: This equipment must be installed to comply with all applicable federal, state and local plumbing codes and ordinances. WARNING ELECTRIC SHOCK HAZARD: Brewer must be properly grounded to prevent possible shock hazard. DO NOT assume a plumbing line will provide such a ...
Page 8 - OPERATION; Fig. 3 Brewer Operation Diagram
OPERATION Fig. 3 Brewer Operation Diagram 6 M62 8 76201 Ow ner s M a n u a l 8781A Tea B re w e r
Page 9 - B. OPERATIONAL NOTES
OPERATION (continued) 7 A. START-UP For initial start-up, or if the brewer has not been used for an extended period of time: ♦ Be sure spray disk and brew gasket are properly installed in the brew head. ♦ Be sure the water supply is properly connected and the water supply valve is turned ON . ♦ Be s...
Page 10 - , pressing the BREW switch; HOT WATER FAUCET; OPEN
OPERATION (continued) WATER HEATER Water temperature is sensed by a thermobulb inserted into the water tank. This temperature signal is fed to the mechanical thermostat. The setpoint temperature is adjustable. Heating element is energized by the thermostat. Excessive temperature will trip the hi-lim...
Page 11 - B. AUTOMATIC OPERATION; EMPTY; BREWING COFFEE; Fig. 6 Coffee Brew Chamber
A. PREPARATION Examine the coffee brew chamber to verify that the tall the wire rack is in place. Place one (1) genuine Bloomfield paper filter into the wire rack in the coffee brew chamber. Add a pre-measured amount of fresh coffee grounds. Gently shake the brew chamber to level the bed of grounds....
Page 12 - BREWING TEA
BREWING TEA 10 A. PREPARATION Examine the tea brew chamber to verify that the short the wire rack is in place. Place one (1) genuine Bloomfield paper filter into the wire rack in the tea brew chamber. Add an amount of fresh tea leaves to the brew chamber appropriate to the desired 1 gallon or 3 gall...
Page 13 - CLEANING INSTRUCTIONS; Remove decanter or dispenser.
CLEANING INSTRUCTIONS PROCEDURE: Clean Coffee/Tea Brewer PRECAUTIONS: Disconnect brewer from electric power. Allow brewer to cool. FREQUENCY: Daily TOOLS: Mild Detergent, Clean Soft Cloth or Sponge Bristle Brush, Bottle Brush 1. Disconnect brewer from electric power. Allow brewer to cool before clea...
Page 14 - TROUBLESHOOTING SUGGESTIONS; TEA
TROUBLESHOOTING SUGGESTIONS 12 SYMPTOM POSSIBLE CAUSE SUGGESTED REMEDY Water won't heat Brewer unplugged or circuit breaker tripped Check power supply cord Check / reset circuit breaker Temperature setpoint too low Set for desired temperature Hi-Limit safety switch tripped Allow to cool hi-limit wil...
Page 15 - coffee
TROUBLESHOOTING SUGGESTIONS 13 SYMPTOM SUGGESTED REMEDY Poor coffee quality Keep brewer, brew chamber and decanters clean. Install a taste and odor filter in water supply, and replace cartridges regularly. Use a quality coffee with a consistent roast. Use proper grind and amount of coffee per brew. ...
Page 16 - SERVICING INSTRUCTIONS; ACCESS PANELS
SERVICING INSTRUCTIONS CAUTION Electric Shock Hazard Opening access panels on this brew may expose uninsulated electrical components. Disconnect brewer from electrical power before removing any panel. ACCESS PANELS TOP PANEL: Remove top panel to access hot water tank, thermostat, heating element, br...
Page 17 - TEMPERATURE ADJUSTMENT; Fig. 10 Checking and Adjusting Brew Temperature; TEM; Fig. 11 Adjust Thermostat
SERVICING INSTRUCTIONS 15 TEMPERATURE ADJUSTMENT Unplug power cord or turn circuit breaker OFF. Remove top panel. Pull vent tube out of tank lid and insert a thermometer of known accuracy in hole. Reconnect brewer to electrical power. Place empty container under brew chamber. Energize brewer and all...
Page 20 - Any abrasion or; Fig. 15 Faucet Repair
SERVICING INSTRUCTIONS (continued) 18 REPAIR HOT WATER FAUCET Remove top panel and turn faucet valve OFF. Unscrew aerator cap from faucet and remove handle retaining clip. Do not let faucet body turn. Pull bonnet assembly from faucet body. Examine the interior of the faucet body and the surface of t...
Page 21 - PROCEDURE: Delime the Water Tank; Reinstall wiring to heating element and thermostat.
SERVICING INSTRUCTIONS (continued) 19 CAUTION - CHEMICAL BURN HAZARD Deliming chemicals are caustic. Wear appropriate protective gloves and goggles during this procedure. Never siphon deliming chemicals or solutions by mouth. This operation should only be performed by qualified and ex-perienced serv...
Page 22 - 781A EXPLODED VIEWS & PARTS LIST
8781A EXPLODED VIEWS & PARTS LIST 20 M6 28 76201 Ow ners Ma nual 8 7 8 1 A T e a B rewer
Page 24 - SERVICE KITS; TANK LID ASSEMBLY
8781A SERVICE KITS 22 SERVICE KITS FAUCET REPAIR KITS 82573 Handle 82575 Seat Cup 82576 Faucet Repair Kit (Includes Handle, Seat Cup, Spring, Stem, Pin & Bonnet 82682 Retainer Clip 84804 Aerator Replacement Kit (Includes O-Ring, Aerator Disk & Aerator Cap 84870 Aerator Repair Kit (Includes O...
Page 26 - for
Bloomfield Industries, Inc. Division of Carrier Commercial Refrigeration In US and Canada Telephone: 775-698-5700 Fax: 888-492-2783 Fax: 800-356-5142 ( ) website: www.wellsbloomfield.com for orders only PRINTED IN UNITED STATES OF AMERICA