Page 2 - xi
NOTE: For your protection, please note that equipment in this shipment was carefully inspected and packaged by skilled personnel before leaving the factory. Upon acceptance of this shipment, the transportation company assumes full responsibility for its safe delivery. IF SHIPMENT ARRIVES DAMAGED: 1....
Page 3 - Meets Canadian standards; APPLICABILITY
MODEL VOLTS 1ø 50/60Hz WATTS AMPS 1ø POWER SUPPLY CORD 1222 120 1800 15.0 NEMA 5-15P 1222CA k 120 1500 12.8 1225 k 208 4000 19.0 1226 k 240 4000 16.5 NEMA 6-30P 1 TABLE OF CONTENTS SPECIFICATIONS Thank You for purchasing this Bloomfield Industries appliance. Proper installation, professional operati...
Page 4 - FEATURES AND OPERATING CONTROLS
FEATURES AND OPERATING CONTROLS 2 712 76580 O w n e rs M anu al H o t Wa ter D ispenser
Page 5 - PRECAUTIONS AND GENERAL INFORMATION; WARNING Electric Shock Hazard; Installation; Burn Hazard; AGENCY LISTING INFORMATION
PRECAUTIONS AND GENERAL INFORMATION 3 WARNING: Electric Shock Hazard All servicing requiring access to non-insulated components must be performed by qualified service personnel. Do not open any access panels which require the use of tools. Failure to heed this warning can result in electrical shock....
Page 6 - INSTALLATION; READ THIS CAREFULLY BEFORE STARTING THE INSTALLATION; PLUMBER’S INSTALLATION INSTRUCTIONS; line. Flush water line before connecting to appliance.
INSTALLATION 4 READ THIS CAREFULLY BEFORE STARTING THE INSTALLATION REFER TO EXPLODED VIEWS PAGE 14 FOR COMPONENT NAMES/NUMBERS. Unpack the unit. Inspect all components for completeness and condition. Ensure that all packing materials have been removed from the unit. LEVELING THE UNIT Two Gallon Dis...
Page 7 - water hammer arrester; ELECTRICIAN’S INSTALLATION INSTRUCTIONS; Fig. 2 Water Supply Installation
INSTALLATION (continued) 5 NOTE: This equipment must be installed to comply with applicable federal, state and local plumbing codes and ordinances. WARNING ELECTRIC SHOCK HAZARD: Dispenser must be properly grounded to prevent possible shock hazard. DO NOT assume a plumbing line will provide such a g...
Page 8 - OPERATION; Fig. 3 Dispenser Operation Diagram; WATER HEATER
OPERATION 6 Fig. 3 Dispenser Operation Diagram A. START-UP For initial start-up, or if the dispenser has not been used for an extended period of time: ♦ Be sure the water supply is properly connected and the water supply valve is turned ON . ♦ Be sure the WATER TANK IS FILLED. IMPORTANT: Fill the wa...
Page 10 - TROUBLESHOOTING SUGGESTIONS; SUGGESTED REMEDY
TROUBLESHOOTING SUGGESTIONS SUGGESTED REMEDY Check power supply cord Check / reset circuit breaker Press switch to "ON" Adjust thermostat for desired temperature Allow to cool hi-limit will self-reset Examine wiring & connectors, controller, power board and heating element Repair/replace...
Page 12 - TEMPERATURE ADJUSTMENT; OFF; REPLACE THERMOSTAT
SERVICING INSTRUCTIONS (continued) TEMPERATURE ADJUSTMENT Check temperature at discharge of faucet. Remove thermostat access button plug to access thermostat. Turn thermostat shaft clockwise to increase temperature. REMOVE TANK LID ASSEMBLY Unplug dispenser or turn circuit breaker OFF . Turn OFF wat...
Page 13 - REPAIR HOT WATER FAUCET
SERVICING INSTRUCTIONS (continued) IMPORTANT: When replacing heating element, also replace seal gaskets. NOTE: Any abrasion or roughness on the flat end of the seat cup will require replacing the seat cup: REPLACE HEATING ELEMENT Remove tank lid assembly as detailed on page 10. Remove two hex nuts h...
Page 14 - PROCEDURE: Delime the Water Tank
CAUTION - CHEMICAL BURN HAZARD Deliming chemicals are caustic. Wear appropriate protective gloves and goggles during this procedure. Never siphon deliming chemicals or solutions by mouth. This operation should only be performed by qualified and experienced service personnel. IMPORTANT: DO NOT spill,...
Page 15 - EXPLODED VIEWS AND PARTS LISTS; SERVICE KITS
EXPLODED VIEWS AND PARTS LISTS 13 SERVICE KITS FAUCET REPAIR KITS 84686 Faucet & Shank Complete 8700-25 L Seat Cup (only) SOLENOID REPAIR KITS 83612 Solenoid Complete, Single 120V (1222, 1222CA) 83760 Solenoid Complete, Single 240V (1225, 1226) 85218 Inlet Fitting Kit (includes cap, fitting, was...
Page 16 - EXPLODED VIEW & PARTS LIST
EXPLODED VIEW & PARTS LIST 14 NOTE: Model 1225/1226 shown. Model 1222/1222CA is similar. 712 76580 O w n e rs M anu al H o t Wa ter D ispenser
Page 18 - WIRING DIAGRAM
WIRING DIAGRAM 16 2-GALLON MODELS 1222 and 1222CA 712 76580 O w n e rs M anu al H o t Wa ter D ispenser
Page 20 - for
Bloomfield Industries, Inc. Division of Carrier Commercial Refrigeration In US and Canada Telephone: 775-689-5700 Fax: 888-492-2783 Fax: 800-356-5142 ( ) website: www.wellsbloomfield.com for orders only Bloomfield Industries proudly supports CFESA Commercial Food Equipment Service Association PRINTE...