Page 2 - xi
NOTE: For your protection, please note that equipment in this shipment was carefully inspected and packaged by skilled personnel before leaving the factory. Upon acceptance of this shipment, the transportation company assumes full responsibility for its safe delivery. IF SHIPMENT ARRIVES DAMAGED: 1....
Page 4 - FEATURES AND OPERATING CONTROLS - AUTOMATIC BREWERS; Fig. 1 Features & Operating Controls for Automatic Brewers
FEATURES AND OPERATING CONTROLS - AUTOMATIC BREWERS 2 Fig. 1 Features & Operating Controls for Automatic Brewers 685 77110 Ow ners M a n ual Ho ri z o n™ Brew ers
Page 5 - FEATURES AND OPERATING CONTROLS - POUR-OVER BREWERS
FEATURES AND OPERATING CONTROLS - POUR-OVER BREWERS 3 Fig. 2 Features & Operating Controls for Pour-Over Brewers 685 771 10 Ow ner s M anual H o ri zo n™ Br ewe rs
Page 6 - PRECAUTIONS AND GENERAL INFORMATION; Failure to heed this warning can result in electrical shock.; AGENCY LISTING INFORMATION
PRECAUTIONS AND GENERAL INFORMATION 4 WARNING: ELECTRIC SHOCK HAZARD All servicing requiring access to non-insulated components must be performed by qualified service personnel. Do not open any access panels which require the use of tools. Failure to heed this warning can result in electrical shock....
Page 7 - INSTALLATION; READ THIS CAREFULLY BEFORE STARTING THE INSTALLATION; Various combinations of legs and spacers are available
INSTALLATION 5 READ THIS CAREFULLY BEFORE STARTING THE INSTALLATION Unpack the unit. Inspect all components for completeness and condition. Ensure that all packing materials have been removed from the unit. Verify that the Spray Head Gasket and Spray Disk are properly installed. LEVELING THE UNIT Ve...
Page 8 - WATER; line. Flush water line before connecting to Brewer.
INSTALLATION (continued) 6 READ THIS CAREFULLY BEFORE STARTING THE INSTALLATION PLUMBER’S INSTALLATION INSTRUCTIONS (AUTOMATIC BREWERS) Brewer should be connected to a POTABLE WATER, COLD WATER line. Flush water line before connecting to Brewer. DO NOT use a saddle valve with a self-piercing tap for...
Page 9 - Before connecting to electricity, make sure; Fig. 4 Power Supply Plug
INSTALLATION (continued) 7 WARNING: SHOCK HAZARD Brewer must be properly grounded to prevent possible shock hazard. DO NOT assume a plumbing line will provide such a ground. Electrical shock will cause death or serious injury. IMPORTANT: Supply power must match nameplate for voltage and phase. Conne...
Page 10 - OPERATION; ON
OPERATION A. START-UP For initial start-up, or if the brewer has not been used for an extended period of time: ♦ Be sure spray disk and brew gasket are properly installed in the brew head. ♦ Be sure the water supply is properly connected and the water supply valve is turned ON . ♦ Be sure the WATER ...
Page 11 - BREWING COFFEE; B. AUTOMATIC OPERATION; EMPTY; BURN HAZARD
BREWING COFFEE A. PREPARATION Place one (1) genuine Bloomfield paper filter in the brew chamber. Add a pre-measured amount of fresh coffee grounds. Gently shake the brew chamber to level the bed of grounds. Slide the brew chamber into place under the brew head. B. AUTOMATIC OPERATION Be sure “READY”...
Page 12 - INSIDE
CLEANING INSTRUCTIONS PROCEDURE: Clean Coffee Brewer PRECAUTIONS: Disconnect brewer from electric power. Allow brewer to cool. FREQUENCY: Daily TOOLS: Mild Detergent, Clean Soft Cloth or Sponge Bristle Brush, Bottle Brush 1. Disconnect brewer from electric power. Allow brewer to cool before cleaning...
Page 13 - TROUBLESHOOTING SUGGESTIONS; SUGGESTED REMEDY
TROUBLESHOOTING SUGGESTIONS SUGGESTED REMEDY Check power supply cord Check / reset circuit breaker Set for desired temperature Allow to cool hi-limit will self-reset Examine wiring & connectors, thermostat and heating element Repair/replace as needed Adjust timer Use one (1) genuine Bloomfield f...
Page 14 - SERVICING INSTRUCTIONS
SERVICING INSTRUCTIONS CAUTION: SHOCK HAZARD Opening access panels or removing warmer plates on this brewer may expose uninsulated electrical components. Disconnect brewer from electrical power before removing any panel Trouble shooting guides, component views and parts lists are included for genera...
Page 15 - TEMPERATURE ADJUSTMENT; Fig. 9 Checking and Adjusting Brew Temperature
SERVICING INSTRUCTIONS (continued) TEMPERATURE ADJUSTMENT Disconnect brewer from electric power. Remove top panel. Remove button plug from front panel. Pull vent tube out of tank lid and insert a thermometer of known accuracy in hole. Reconnect brewer to electrical power. Place empty container under...
Page 16 - DELAY is the amount of; TIMER ADJUSTMENT (AUTOMATIC BREWERS ONLY); OFF; REPLACE HEATING ELEMENT
SERVICING INSTRUCTIONS (continued) 14 IMPORTANT: Water pressure must be between 20 p.s.i and 90 p.s.i. flowing pressure. If water pressure exceeds this value, or if water pressure varies greatly, a pressure regulator must be installed in the water supply line. NOTE: DELAY is the amount of time befor...
Page 18 - REPLACE HOT WATER FAUCET COIL; This faucet body is not interchangeable with the faucets; REPLACE BREW READY LIGHT or BREW BUTTON
SERVICING INSTRUCTIONS (continued) 16 IMPORTANT: When replacing water faucet coil, also replace seal gaskets. NOTE: Any abrasion or roughness on the flat end of the seat cup will require replacing the seat cup: Work the seat cup out of the bonnet and off of the end of the stem. Install a new seat cu...
Page 19 - allow; PROCEDURE: Delime the Water Tank
SERVICING INSTRUCTIONS (continued) 17 CAUTION: CHEMICAL BURN HAZARD Deliming chemicals may be caustic. Wear appropriate protective gloves and goggles during this procedure. Never siphon deliming chemicals or solutions by mouth. This operation should only be performed by qualified and experienced ser...
Page 20 - EXPLODED VIEW & PARTS LIST; PLUMBING & RELATED COMPONENTS - AUTOMATIC BREWERS
EXPLODED VIEW & PARTS LIST 18 PLUMBING & RELATED COMPONENTS - AUTOMATIC BREWERS MODELS: 0412, 0472, 0482 685 77110 Ow ners M a n ual Ho ri z o n™ Brew ers
Page 26 - CABINET & ELECTRICAL COMPONENTS - AUTOMATIC AIRPOT/THERMAL BREWER
EXPLODED VIEW & PARTS LIST (continued) 24 CABINET & ELECTRICAL COMPONENTS - AUTOMATIC AIRPOT/THERMAL BREWER MODEL: 0482 685 77110 Ow ners M a n ual Ho ri z o n™ Brew ers
Page 27 - SERVICE KITS
EXPLODED VIEW & PARTS LIST (continued) 25 SERVICE KITS FAUCET REPAIR KITS 82573 Handle (item 12a) 82575 Seat Cup (item 12c) 82576 Faucet Repair Kit (Includes 12a Handle, 12c Seat Cup, 12d Spring, 12h Stem, 12j Pin & 12k Bonnet 82682 Retainer Clip (item 12b) 84804 Aerator Replacement Kit (Inc...
Page 28 - WIRING DIAGRAM; AUTOMATIC BREWERS
WIRING DIAGRAM 26 AUTOMATIC BREWERS 685 77110 Ow ners M a n ual Ho ri z o n™ Brew ers
Page 30 - Division of Carrier Commercial Refrigeration; for
PRINTED IN CHINA Bloomfield Industries, Inc. Division of Carrier Commercial Refrigeration In US and Canada Telephone: 775-689-5700 Fax: 888-492-2783 Fax: 800-356-5142 ( ) website: www.wellsbloomfield.com for orders only Bloomfield Industries proudly supports CFESA Commercial Food Equipment Service A...