Weil-McLain 800059000-Brn-PO Rie F5 - Manual
Weil-McLain 800059000-Brn-PO Rie F5 – Manual, read for free online in PDF format. We hope this helps you resolve any issues you may have. If you have further questions, please contact us through the contact form.
Table of Contents:
- Page 2 – INSTALLLATION PRECAUTIONS; It is suggested that the installer follow CSA standard B139.
- Page 3 – TABLE OF CONTENTS
- Page 4 – combustion head mounted C
- Page 5 – Model; BURNER COMPONENTS; mm
- Page 6 – CHASSIS from their respective cartons.; MOUNTING THE BURNER TO THE BOILER OR FURNACE; Pedestal kit must be ordered separately.; METHOD 1 – UNIVERSAL MOUNTING FLANGE
- Page 8 – AMULET INSTALLATION INSTRUCTIONS; NO AMULET
- Page 9 – INTERNAL FACTORY WIRING; AUX; RIELLO 40 F3 - F5 SERIES OIL BURNERS EQUIPPED
- Page 10 – APPLICATION FIELD WIRING
- Page 12 – OIL LINE CONNECTIONS; do not exceed
- Page 13 – . Be sure there are no air leaks or blockages in the piping sys-; PUMP PURGE; securely and startburner.
- Page 14 – SETTING THE AIR ADJUSTMENT PLATE; The final position of the air adjustment plate will vary on; must; proper test results are obtained.
- Page 15 – BURNER ADJUSTMENT TABLE; NON-RETROFIT APPLICATIONS; BURNER START-UP CYCLE; The above set up charts are a starting point only.; RIELLO; BURNER SET UP SHEET
- Page 16 – EXPLODED SPARE PARTS LIST
- Page 17 – SPARE PARTS LIST
- Page 18 – CODE
- Page 19 – Mississauga,On L5H 3R2
- Page 20 – Technical Support Hotline; 5 Pond Park Road
Installation & Operating Manual
C6501071
(0)
Single stage operation oil burners
RETROFIT APPLICATIONS ONLY
If this burner is being installed in a packaged unit (ie. burner comes with a boiler or furnace), follow
the installation and set-up instructions supplied with the heating unit, as settings may differ from
those shown in this manual.
- The following pages contain information, descriptions and diagrams for the proper installation
and wiring of the burner. Please read carefully before attempting final installation.
- This manual is to remain with the final installation designation. It is the installer’s responsibility to en-
sure that the burner installation and operation instructions mentioned in this manual are followed and
operated within local code authority limits.
RIELLO 40
CODE MODEL TYPE
C8512
519
8000
57
00
0
-Brn-PO Rie F5
1.00GPH Vnt-
C
C8512
520
8000
58
00
0
-Brn-PO Rie F5
1.20GPH Vnt-
C
C8512
521 8
000
59
00
0
-Brn-PO Rie F5
1.40GPH Vnt-
C
"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.
Summary
3223 GB INSTALLLATION PRECAUTIONS AIR FOR COMBUSTION Do not install burner in room with insufficient air for combustion. Be sure there is an adequate air supply forcombustion if the boiler/furnace room is enclosed. It may be necessary to create a window to permit suffi-cient air to enter the boiler/...
3223 GB TABLE OF CONTENTS PACKAGE CONTENTS LIST . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 SERIAL NUMBER IDENTIFICATION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ....
3223 1 GB PACKAGE CONTENTS LIST Your Riello 40 burner should include the following parts. Please check to make sure all parts are present before begin-ning the installation. SERIAL NUMBER IDENTIFICATION Your Riello burner may have been manufactured in more than one location and therefore there are t...