Wayne JCU50 - Manual

Wayne JCU50

Wayne JCU50 – Manual, read for free online in PDF format. We hope this helps you resolve any issues you may have. If you have further questions, please contact us through the contact form.

1 Page 1
2 Page 2
3 Page 3
4 Page 4
5 Page 5
6 Page 6
7 Page 7
8 Page 8
9 Page 9
10 Page 10
11 Page 11
12 Page 12
13 Page 13
14 Page 14
15 Page 15
16 Page 16
17 Page 17
18 Page 18
19 Page 19
20 Page 20
21 Page 21
22 Page 22
23 Page 23
24 Page 24
25 Page 25
26 Page 26
27 Page 27
28 Page 28
29 Page 29
30 Page 30
31 Page 31
32 Page 32
33 Page 33
34 Page 34
35 Page 35
36 Page 36
Page: / 36

Table of Contents:

  • Page 2 – Air Volume
  • Page 3 – Installation; Horizontal Distance
  • Page 4 – DEEP WELL INSTALLATION
  • Page 5 – Electrical; Operating Instructions and Parts Manual; Install a valve and isolating hose
  • Page 6 – Operation; PRIMING THE SHALLOW WELL PUMP; DRAINING THE TANK; Maintenance; DRAINING THE PUMP
  • Page 7 – LUBRICATION; INSTALLING NEW SHAFT SEAL
  • Page 8 – li
  • Page 9 – Symptom; Troubleshooting Chart
  • Page 10 – Description
  • Page 11 – Performance
  • Page 12 – Limited Warranty
  • Page 13 – Déballage; Manuel d’Utilisation et Pièces de Rechange; Sécurité Personnelle:; MÉMENTO: Gardez votre preuve datée d'achat à fin de la garantie!
  • Page 14 – Contrôle de; TABLEAU 1 - MONTAGES DE POMPE À JET/RÉSERVOIR
  • Page 15 – sur les filets en plastique. Tous; Distance Horizontale; Puits Profond Arrivée: Aspiration
  • Page 16 – INSTALLATION DE PUITS DE SURFACE
  • Page 17 – TABLEAU 3 - RECOMMANDATIONS DE FUSIBLE ET DE FILS - MOTEURS 60 HZ; Électrique
  • Page 19 – Entretien
  • Page 20 – NOTES
  • Page 21 – rc
  • Page 22 – Symptôme; Guide De Dépannage
  • Page 23 – S’il vous plaît fournir l’information suivante:
  • Page 24 – Garantie Limitée; DEVEZ
  • Page 25 – Descripción; Para Desempacar; Medidas de Seguridad; Manual de instrucciones de operación y piezas; los líquidos del sistema.; Adjúntela a este manual o archívela en lugar seguro.
  • Page 26 – FUENTES DE SUMINISTRO DE AGUA; Se Necesita; TABLA 1 - ENSAMBLADOS DE
  • Page 27 – Instalación; . Todas las conexiones deben; Distancia Horizontal; Salida
  • Page 28 – INSTALACIÓN EN UN PROFUNDO; TAMANOS DE LOS TUBOS
  • Page 31 – LUBRICACIÓN; Funcionamiento; DRENAJE DEL BOMBA
  • Page 32 – Mantenimiento; PRECARGADO
  • Page 33 – is
  • Page 34 – Problema; Guía de Diagnóstico de Averías
  • Page 35 – Envíe su solicitud de repuestos a la siguiente direccion:
  • Page 36 – Garantía Limitada; DEBE; Rendimiento
Loading the manual

Jet Pump Water Systems

Please read and save these instructions. Read carefully before attempting to assemble, install, operate or maintain the product
described. Protect yourself and others by observing all safety information. Failure to comply with instructions could result in per-
sonal injury and/or property damage! Retain instructions for future reference.

© 2008 Wayne Water Systems

Description

Jet pumps are single stage domestic
water pumps designed for pumping
potable water in applications where
the water is as much as 100 feet under
ground (deep well pump). A pressure
switch is a standard feature. Deep well
pumps can be mounted to either a
precharged, conventional type or free
standing pressure tank.

Unpacking

After unpacking the jet pump, carefully
inspect for any damage that may have
occurred during transit. Check for
loose, missing or damaged parts.

Safety Guidelines

This manual contains information that
is very important to know and under-
stand. This information is provided for
SAFETY and to PREVENT EQUIPMENT
PROBLEMS. To help recognize this
information, observe the following
symbols.

Danger indicates

an imminently haz-

ardous situation which, if not avoided,
will result in death or serious injury.

Warning indicates

a potentially haz-

ardous situation which, if not avoided,
could result in death or serious injury.

Caution indicates a

potentially haz-

ardous situation which, if not avoided,
may result in minor or moderate injury.

Notice indicates

important informa-

tion, that if not followed, may cause
damage to equipment.

Operating Instructions and Parts Manual

JCU50

General Safety
Information

1. Read the instruction manual included

with the product carefully. Be thor-
oughly familiar with the controls and
the proper use of the equipment.

2. Know the pump application, limita-

tions and potential hazards.

Do not use to pump
flammable or explo-

sive fluids such as gasoline, fuel oil,
kerosene, etc. Do not use in explosive
atmospheres. Pump should only be used
with liquids compatible with pump com-
ponent materials. Failure to follow this
warning can result in personal injury
and/or property damage.

Disconnect power
and release all pres-

sure from the system before attempting
to install, service, relocate or perform any
maintenance. Lock the power disconnect
in the open position. Tag the power dis-
connect to prevent unexpected applica-
tion of power.

Install a screen
around the inlet

pipe to prevent entrapment of swimmers.

3. Drain all liquids from the system

before servicing.

4. Secure the discharge line before

starting the pump. An unsecured dis-
charge line will whip and possibly
cause personal injury and/or property
damage.

5. Check hoses for weak or worn condi-

tion before each use. Make certain
all connections are secure.

6. Periodically inspect pump and system

components. Perform routine main-
tenance as required (See
Maintenance).

7.

Personal Safety:

a.

Wear safety glasses at all times
when working with pumps.

b.

Keep work area clean, unclut-
tered and properly lighted -

340702-001 7/08

replace all unused tools and
equipment.

c.

Keep visitors at a safe distance
from work area.

d.

Make the workshop child
proof: use padlocks, master
switches and remove starter
keys.

8. Do not pump chemicals or corrosive

liquids. Pumping these liquids
shortens the life of the pumps seals
and moving parts and will void the
warranty.

9. When installing pump, cover the

well to prevent foreign matter
from falling into well, contaminat-
ing the water and damaging inter-
nal mechanical pumping compo-
nents.

10. Always test the water from the

well for purity before use. Check
with local health department for
test procedure.

11. Complete pump and piping system

MUST be protected against below
freezing temperature. Freezing
temperatures could cause severe
damage and void the warranty.

12. Do not run the pump dry or damage

will occur and will void warranty.

Risk of electrical

shock. This pump is

designed for indoor installation only.

All wiring should be
performed by a

licensed or certified electrician.

13. For maximum safety, the unit

should be connected to a grounded
circuit equipped with a ground
fault interrupter device.

14. Before installing the pump, have

the electrical outlet checked by a
licensed or certified electrician to
make sure the outlet is properly
grounded.

See Warranty on page 12 for important information about commercial use of this product.

REMINDER: Keep your dated proof of purchase for warranty purposes! Attach it to this manual or file it for safekeeping.

For parts, product & service information

visit

www.waynewatersystems.com

"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.

Summary

Page 2 - Air Volume

and 3-pole receptacles that acceptthe equipment plug. 22. Use wire of adequate size to mini- mize voltage drop at the motor. Do not handle pump or pump motor with wet hands, when standingon a wet or damp surface or whenstanding in water. Fatal electricalshock could occur. Pump motor is equipped with...

Page 3 - Installation; Horizontal Distance

3 Pre-Installation (Cont’d) PACKAGE SYSTEMS There are four jet pump/tank assem-blies sold as packages (Chart 1). WELLS A new well should be pumped clear ofsand before installing the pump. Sandwill damage the pumping parts andseal. The drawdown level of the wellshould not exceed the maximum rateddept...

Page 4 - DEEP WELL INSTALLATION

included) to the jet body. A 1 1 / 4 ” coupling is required to connect thelarger pipe to the jet assembly. 2. Connect the 1” pipe threads into the smaller opening in the jet body. 3. Lower the jet into the well. Add pipe as needed. Be sure to use pipejoint compound on all male threads. 4. Position t...

Other Wayne Models

All Wayne Other