Wayne 200000-015 - Manual

Wayne 200000-015

Wayne 200000-015 – Manual, read for free online in PDF format. We hope this helps you resolve any issues you may have. If you have further questions, please contact us through the contact form.

1 Page 1
2 Page 2
3 Page 3
4 Page 4
5 Page 5
6 Page 6
7 Page 7
8 Page 8
9 Page 9
10 Page 10
11 Page 11
12 Page 12
13 Page 13
14 Page 14
15 Page 15
16 Page 16
17 Page 17
18 Page 18
19 Page 19
20 Page 20
21 Page 21
22 Page 22
23 Page 23
24 Page 24
Page: / 24

Table of Contents:

  • Page 2 – INSTALLATION MANUAL; TYPICAL SUMP INSTALLATION DIAGRAMS; Printed on 100% Recycled Paper
  • Page 3 – CHART — A; CHART — B
  • Page 4 – TYPICAL EFFLUENT INSTALLATION
  • Page 5 – TYPICAL SEWAGE INSTALLATION
  • Page 6 – MAINTENANCE; TROUBLESHOOTING
  • Page 9 – POMPE DE PUISARD; DÉBALLAGE; LIRE ET SUIVRE TOUTES LES INSTRUCTIONS; Les pompes de puisard, d’effl uent et d’égout; MANUEL D’INSTALLATION
  • Page 10 – DIAGRAMMES D’INSTALLATION DE POMPES DE PUISARD TYPIQUES
  • Page 11 – TABLEAU — A; TABLEAU — B
  • Page 14 – ENTRETIEN; DÉPANNAGE
  • Page 17 – BOMBAS DE SUMIDERO; DESEMPAQUE; LEA Y SIGA TODAS LAS INSTRUCCIONES; Bombas para sumidero, aguas residuales y aguas negras; MANUAL DE INSTALACIÓN
  • Page 18 – DIAGRAMAS TÍPICOS DE INSTALACIÓN DE SUMIDEROS
  • Page 19 – TABLA — A; TABLA — B
  • Page 22 – MANTENIMIENTO; DIAGNÓSTICO Y RESOLUCIÓN DE PROBLEMAS
Loading the manual

SAFETY GUIDELINES

This manual contains information that is very important

to know and understand. This information is provided

for SAFETY and to PREVENT EQUIPMENT PROBLEMS.

To help recognize this information, observe all safety

information labelled danger, warning, caution, and notice.

DESCRIPTIONS

SUMP PUMPS

Sump pumps are automatic pumps used to remove ground
water from sump pits. The most common application is for
basement drainage to prevent fl ooding in residential buildings.
These sumps are designed to pump clear water only.

EFFLUENT PUMPS

Effl uent pumps are pumps used to remove gray water from
septic tanks, sump pits or laundry tray systems. Gray water
is waste water from baths, sinks, washing machines, and
other kitchen appliances. The pumps are designed to pass
solids up to 3/4 in.

SEWAGE PUMPS

Sewage pumps are pumps used to remove waste water
that contains solids up to 2 inches in diameter. The most
common application is for draining bathroom waste water to
a sewer or septic line.

UNPACKING

Inspect your pump. Occasionally, products are damaged during
shipment. If the unit is damaged, return the unit to the place of
purchase for replacement.

READ & FOLLOW ALL INSTRUCTIONS

SAVE THESE INSTRUCTIONS — DO NOT DISCARD

200000-015 6/10

© 2010

Sump, Effl uent and Sewage pumps

INSTALLATION MANUAL

IMPORTANT SAFETY INFORMATION

WARNING INDICATES A POTENTIALLY HAZARDOUS
SITUATION WHICH, IF NOT AVOIDED, COULD RESULT
IN DEATH OR SERIOUS INJURY.

RISK OF ELECTRIC SHOCK. TO REDUCE THIS

RISK, OBSERVE THE FOLLOWING WARNINGS:

MAKE SURE THERE IS A PROPERLY GROUNDED
RECEPTACLE AVAILABLE.

This pump is supplied with a

grounding conductor and grounding-type attachment plug. To
reduce the risk of electric shock, be certain that it is connected
only to a properly grounded, grounding-type receptacle.

NEVER REMOVE THE GROUND PRONG

from the plug or

bypass the grounding wires.

FOR ADDED SAFETY

the receptacle should be protected with a

ground fault circuit interrupter (GFCI). All wiring must be performed
by a qualifi ed licensed electrician and comply with the National
Electric Code and all applicable local codes and ordinances.

DO NOT REMOVE POWER SUPPLY CORD

and strain relief or

connect conduit directly to the pump.

MAKE SURE THE POWER SUPPLY HAS A FUSE OR
CIRCUIT BREAKER

rated to handle the current (amps) noted

on the nameplate of the pump.

DO NOT USE AN EXTENSION CORD.

Extension cords could

present a safety hazard if not sized properly, become damaged
or the connection falls into the sump. If receptacle is not within
reach of the pump’s power cord, contact a qualifi ed licensed
electrician to install a new receptacle.

ALWAYS DISCONNECT THE PUMP

from power supply before

installing, servicing or making any adjustments.

DO NOT SUBMERGE PEDESTAL MOTOR

or allow motor to

be exposed to water.

DO NOT WALK

on the fl oor when water is present until all

power is turned off. If the electric panel is in the basement, call
an electrician.

NEVER HANDLE A PUMP

or motor with wet hands or when

standing on a wet or damp fl oor while the pump is plugged into
the power supply.

WASH HANDS AFTER HANDLING.

According to the state of

California (Prop 65), this product may contain chemicals known to
the state of California to cause cancer and birth defects or other
reproductive harm.

RISK OF ELECTRIC SHOCK.

This pump has not been

investigated for use in swimming pool and marine areas.

DO NOT USE TO PUMP FLAMMABLE OR EXPLOSIVE FLUIDS

such as gasoline, fuel oil, kerosene, etc. Do not use in a fl ammable
and/or explosive atmosphere. Pump should only be used to pump
clear water. Personal injury and/or property damage could result.

Read and save these instructions. This manual contains very important Safety Warnings and Operating Instructions. You will need to refer to
it before attempting any installation or maintenance. Always keep this manual with the unit so that it will be easily accessible. Failure to read
and follow these warnings and instructions could result in property damage, serious injury or death.

Printed on 100% Recycled Paper

"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.

Summary

Page 2 - INSTALLATION MANUAL; TYPICAL SUMP INSTALLATION DIAGRAMS; Printed on 100% Recycled Paper

INSTALLATION MANUAL CAUTION INDICATES A POTENTIALLY HAZARDOUS SITUATION WHICH, IF NOT AVOIDED, MAY RESULT IN MINOR OR MODERATE INJURY. TO REDUCE THE RISK OF HAZARDS THAT CAN CAUSE INJURY OR PROPERTY DAMAGE, OBSERVE THE FOLLOWING WARNINGS: IF THIS PUMP CONTAINS A SWITCH FOR AUTOMATIC OPERATION, IT IS...

Page 3 - CHART — A; CHART — B

INSTALLATION MANUAL 8. Drill 1/8 in. “weep” hole in the discharge pipe 1 in. above the pump discharge. Water stream will be visible from the how when the pump is running. The hole must be cleaned periodically. 9. Install a union to allow for easy removal of the pump for cleaning or service. 10. Inst...

Page 4 - TYPICAL EFFLUENT INSTALLATION

4 INSTALLATION MANUAL Figure 3: Effl uent Pump in Septic Tank 1. This installation must be in accordance with the National Electric Code and all applicable local codes and ordinances. 2. For sump applications, follow typical sump installation instructions. For effl uent applications, continue to ste...