Vulcan ML-052208 - Manual
Vulcan ML-052208 – Manual, read for free online in PDF format. We hope this helps you resolve any issues you may have. If you have further questions, please contact us through the contact form.
Table of Contents:
- Page 2 – TABLE OF CONTENTS
- Page 4 – GENERAL
- Page 5 – IMPORTANT
- Page 6 – REMOVAL AND REPLACEMENT OF PARTS; COVERS, PANELS AND HANDLES
- Page 11 – GRID CARRIAGE ASSEMBLY
- Page 13 – BURNER ASSEMBLY
- Page 25 – LEVER ARM ASSEMBLY
- Page 26 – BLOWER AND MOTOR
- Page 28 – SERVICE PROCEDURES AND ADJUSTMENTS; GAS SUPPLY CHECKS
- Page 31 – TROUBLESHOOTING
V U L C A N - H A R T C O M P A N Y , P . O . B O X 6 9 6 , L O U I S V I L L E , K Y 4 0 2 0 1 - 0 6 9 6 , T E L . ( 5 0 2 ) 7 7 8 - 2 7 9 1
– NOTICE –
This Manual is prepared for the use of trained Vulcan Service Technicians and should not be used by those not properly
qualified. If you have attended a Vulcan Service School for this product, you may be qualified to perform all the procedures
described in this manual.
This manual is not intended to be all encompassing. If you have not attended a Vulcan Service School for this product,
you should read, in its entirety, the repair procedure you wish to perform to determine if you have the necessary tools,
instruments and skills required to perform the procedure. Procedures for which you do not have the necessary tools,
instruments and skills should be performed by a trained Vulcan Service Technician.
Reproduction or other use of this Manual, without the express written consent of Vulcan, is prohibited.
For additional information on Vulcan-Hart Company or to locate an authorized
parts and service provider in your area, visit our website at www.vulcanhart.com
SERVICE MANUAL
HEAVY DUTY GAS BROILER
MODELS
GHCB40
ML-052211
GHCB44
ML-052213
GHMCB44
ML-052214
HCB1
ML-052202
HCB2(B)
ML-052208
IR1
ML-052200
IR2(B)
ML-052201
GHIR44
ML-052210
FORM 35608 (Aug. 2003)
GHCB40 SHOWN
"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.
Summary
– 2 – TABLE OF CONTENTS GENERAL ................................................................................................................................................................ 4 Introduction ...............................................................................................
– 4 – SPECIFICATIONS Gas Data Model Dimensions No. of Total Burners BTU Width Depth Height per /hr Section GHCB40 34” 39 1 / 8 ” 79” 4 100,000 GHCB44 34” 39 1 / 8 ” 79” 4 100,000 GHMCB44 3 4 ” 39 1 / 8 ” 5 7 ” 4 100,000 HCB1 3 6 ” 38 3 / 8 ” 6 8 ” 4 50,000 HCB2(B) 3 6 ” 38 3 / 8 ” 80 1 / 2 ” 4 100,0...
– 5 – IMPORTANT STOP BOLTS MUST BE IN POSITION FOR SAFE OPERATION OF GRID. IF DAMAGED OR MISSING,REPLACE AT ONCE. DO NOT OPERATE GRID WITHOUT BOLTS. Two (2) broiler grid 1/4-20 stop bolts and nuts are supplied with each broiler grid to ensure that the grid is notaccidentally pulled completely from t...